NOTE: Verify your calibration. Use full flow
when calibrating. Meter accuracy is based
on proper calibration for each herbicide and
fluid temperature.
1. Fill pump, meter, hose and system by turn-
ing pump on, holding nozzle open, and fill-
ing a container until a full solid flow occurs.
Close nozzle.
2. Reset main meter dial to 000.0. Turn count-
er reset knob counterclockwise.
3. Fill a carefully measured 5 gallon container
(GPI Calibration Container P/N 116000-1)
up to marked point.
4. Note meter counter reading. If the meter
registers less than the container volume,
remove seal screw (111039-2) and turn the
calibration screw (111014-3) clockwise. If
main counter reading is more than con-
tainer volume, turn calibration screw coun-
terclockwise.
5. Continue calibration steps above until
counter reading is equal to measurement
container volume. Reinstall seal screw.
Owners Manual for
Model FM100H Meter
GENERAL INFORMATION
To the Owner:
Please read the manual carefully before us-
ing your new meter. The information provided
will help you achieve years of dependable per-
formance and trouble-free operation.
•Lightweight, corrosion resistant cast
aluminum body
•Burnished aluminum finish
•Registers up to 999.9 gallons (9,999 litres)
per delivery
•Totalizer registers up to 99,999 gallons
(999,999 litres)
•50 psi (3.4 bar) maximum working pressure
•Large reset knob
•Operating range: 4-20 GPM (15-75 LPM)
•Inlet and outlet thread: 1” NPT or (1” BSPP)
Approved Chemicals for
Model FM100H Herbicide Meter
The GPI Herbicide Meter has been tested and
approved for most mini-bulk herbicides and
other chemicals that are compatible with alu-
minum, Viton®, thermoplastic polyester, stain-
less steel and Delrin®.
Thread pipe nipple into pump outlet. Using
bushing if required, install meter by applying
Teflon®tape to threads and turning meter onto
nipple.
NOTE: Meter outlet is marked on meter
housing.
Attach hose and nozzle to meter outlet using
Teflon®tape on all threads.
SPECIFICATIONS
INSTALLATION
Rev. A 921626-2
WARNING
GPI Herbicide Meter is approved to handle
only herbicides that are compatible with
meter materials. Meter is not approved for
gasoline, diesel and other fuels.
C A U T I O N
Always wear goggles, protective gloves,
and any other protection required for han-
dling herbicides. Observe all safety in-
structions for herbicides when handling
or servicing equipment.
CALIBRATION
5252 East 36th Street North
Wichita, KS USA 67220-3205
TEL: 316-686-7361
FAX: 316-686-6746
“A Great Plains Ventures Subsidiary”
www.gpi.net
1-800-835-0113
11/05

Proper cleaning is mandatory for long life.
Herbicide equipment requires cleaning much
like spray paint equipment. Many herbicides
will harden in a very short period of time and
cause severe damage. Improper cleaning will
also void the warranty.
The meter should be flushed with water at the
end of each day.
NOTE: Meter reading will change as meter is
flushed.
Remove the pump and meter from herbicide
container. Insert suction pipe into water. Turn
pump on and alternate opening and closing
nozzle until water is free of herbicide residue.
After flushing, let water drain out of suction pipe
and open nozzle to clear most of the water out
of the hose and meter.
NOTE: For best results, disassemble, clean
and inspect annually and replace seals.
Drain herbicide from meter and flush with wa-
ter as described under maintenance.
1. To replace counter and gear assembly,
nutating disc and corresponding seals; re-
move knob (111028-2).
2. Remove 2 screws (904002-13) connecting
the coverplate to the main housing. Then
remove coverplate.
3. Remove 4 screws (904002-12) which hold
counter assembly and then remove this
assembly.
4. Remove 2 screws (904003-37) to remove
the nutator disc assembly (if needed).
5. To reassemble, reverse the above proce-
dure, ensuring that all seals are carefully
in place.
MAINTENANCE
WARNING
DO NOT STORE METER WITH WATER IN
CAVITIES. For prolonged periods of stor-
age, flush and drain as outlined above.
See Assembly/Disassembly instructions
for inspection of counter assembly and
nutator disc assembly. Inspect and clean
any remaining herbicide residue from
meter interior, reinstall covers and fill
meter with ethylene glycol (antifreeze).
ASSEMBLY / DISASSEMBLY
For warranty consideration, parts, or other ser-
vicing information, please contact your local dis-
tributor. If you need further assistance, call the
GPI Customer Service Department in Wichita,
Kansas, during normal business hours.
1-800-835-0113
To obtain prompt, efficient service, always be
prepared with the following information:
1. The model number of your meter.
2. The serial number or manufacturing date
code of your meter.
3. Specific information about part numbers and
descriptions.
For warranty work always be prepared with your
original sales slip or other evidence of purchase
date.
Returning Parts
Please contact the factory before returning any
parts. It may be possible to diagnose the trouble
and identify needed parts in a telephone call or
letter. GPI can also inform you of any special
handling requirements you will need to follow
covering the transportation and handling of
equipment which has been used to transfer haz-
ardous liquids.
CAUTION: Do not return meters without spe-
cific authority from the GPI Customer Ser-
vice Department. Due to strict regulations
governing transportation, handling, and
disposal of hazardous liquids, GPI will not
accept meters for rework unless they are
completely free of chemical.
SERVICE

TROUBLESHOOTING
SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION
A. LEAKAGE INTO COUNTER 1. Shaft seal leaking. Return to manufacturer for repair.
B. EXTERNAL LEAKAGE 1. Pipe fitting installed without Seal pipe ends with suitable sealer.
sealer.
2. Fasteners loose. Tighten fasteners.
3. O-ring deleted or improperly Install O-ring or correct faulty installation.
installed.
4. Cracked assembly. Replace defective part.
C. METER RUNS IN REVERSE 1. Piping incorrectly installed. Install piping in accordance with flow
direction on meter.
D. DUST COLLECTING INSIDE 1. Dust seals, O-ring or knob Install seals or correct seal installation.
COUNTER COVER seal not installed, incorrect-
ly installed or damaged.
2. Fastener loose or missing. Tighten or replace fastener.
E. DELIVERY NORMAL BUT 1. Broken counter assembly. Return unit to manufacturer for repair.
2. Foreign material in counter Clean meter cavity.
assembly.
3. Misaligned nutator Correct alignment. Make certain lip is en-
assembly. gaged in inlet hole, O-ring is properly in-
stalled and hold down screws are secured.
4. Debris in nutator assembly. Clean nutator assembly.
5. Defective nutator assembly. Replace nutator assembly.
F. METER REGISTER DOES 1. Faulty meter – clogged Clean or replace strainer. Clean or replace
strainer. counter assembly.
2. No strainer. Foreign mat- Remove foreign material. Install new
erial in nutator assembly. strainer.
3. System components other Isolate cause.
than meter may be at fault.
Limited Warranty Policy
Great Plains Industries, Inc. 5252 E. 36th Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against
defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This product includes a 2 year
warranty. Manufacturer’s sole obligation under the foregoing warranties will be limited to either, at Manufacturer’s option, replacing
or repairing defective Goods (subject to limitations hereinafter provided) or refunding the purchase price for such Goods theretofore
paid by the Buyer, and Buyer’s exclusive remedy for breach of any such warranties will be enforcement of such obligations of
Manufacturer. The warranty shall extend to the purchaser of this product and to any person to whom such product is transferred
during the warranty period.
The warranty period shall begin on the date of manufacture or on the date of purchase with an original sales receipt. This warranty
shall not apply if:
A. the product has been altered or modified outside the warrantor’s duly appointed representative;
B. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in
accordance with the manufacturer’s operating instructions.
To make a claim against this warranty, contact the GPI Customer Service Department at 316-686-7361 or 1-800-835-0113. Or by mail at:
Great Plains Industries, Inc.
5252 E. 36th St. North
Wichita, KS, USA 67220-3205
The company shall, notify the customer to either send the product, transportation prepaid, to the company at its office in Wichita,
Kansas, or to a duly authorized service center. The company shall perform all obligations imposed on it by the terms of this warranty
within 60 days of receipt of the defective product.
GREAT PLAINS INDUSTRIES, INC., EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL
AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER.
The company herewith expressly disclaims any warranty of merchantability or fitness for any particular purpose other than for
which it was designed.
This warranty gives you specific rights and you may also have other rights which vary from U.S. state to U.S. state.
Note: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT – Part 702 (governs the resale availability of the
warranty terms).
METER DOES NOT MOVE
NOT OPERATE, LITTLE OR
NO FLOW

Replacement Kits
111504-1 Seat Kit includes nutator seal, cal screw
seal, housing seal, center cover seal,
and strainer cover seal.
111507-1 Overhaul Kit includes all seals and disc.
Item No.
No. Part No. Description Req’d.
10B 111008-4 Nutator ....................................... 1
10C 111045-4 O-ring ......................................... 1
10D 111009-2 Disc ............................................ 1
11 111021-3 Housing, 1 in. NPT ..................... 1
111021-4 Housing, 1 in. BSPP ................... 1
12 111039-2 Calibration Cover Screw ............ 1
13 904002-19 Calibration Cover Collar ............. 1
14 111014-3 Calibration Screw ....................... 1
15 111045-1 Calibration Screw Seal ............... 1
20 904002-15 Screw, Sems (1/4-20 x 5/8 in.) ... 4
21 901001-78 Strainer Coverplate Seal ............ 1
22 111032-2 Strainer ....................................... 1
23 111029-1 Strainer Coverplate .................... 1
10C
ILLUSTRATED PARTS DRAWING
5252 East 36th Street North
Wichita, KS USA 67220-3205
TEL: 316-686-7361
FAX: 316-686-6746
“A Great Plains Ventures Subsidiary”
www.gpi.net
1-800-835-0113
Rev. A 921626-211/05
Item No.
No. Part No. Description Req’d.
1111034-1 Decal, Gallon .............................. 1
111034-3 Decal, Litre, NPT ........................ 1
2904002-13 Screw, Sems (8-32 x 5/16 in.) .... 2
3111006-1 Counter Cover, Gallon ................ 1
111006-2 Counter Cover, Litre ................... 1
4111028-2 Reset Knob ................................ 1
5111107-1 Grommet .................................... 1
6111024-1 Cover O-ring ............................... 1
7904002-12 Screw, Sems (1/4-20 x 1/2 in.) ... 4
8111047-3 Counter Assembly, Gallon .......... 1
111047-5 Counter Assembly, Litre ............. 1
9118017-1 Housing O-ring ........................... 1
10A 904003-37 Screw, Sems (6-32 x 1/2 in.) ...... 2
GPI is a registered trademark of Great Plains Industries, Inc.
© 2005 by GREAT PLAINS INDUSTRIES, INC., Wichita, KS.
10D
10A
10B
Other GPI Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

HP
HP ESA-E Series Programmer's guide

SENSIT Technologies
SENSIT Technologies HXG-3P Quick start instructions

Greenlee
Greenlee 5990A instruction manual

HACH LANGE
HACH LANGE LZX914.99.12400 instruction sheet

T3 Innovation
T3 Innovation Power Prowler PLR600 quick start guide

DOCTOR SMILE
DOCTOR SMILE WISER 3 user manual