manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GPI
  6. •
  7. Measuring Instrument
  8. •
  9. GPI Flomec 02 Series User manual

GPI Flomec 02 Series User manual

920894-01 Rev. C09/15
SAVE THESE INSTRUCTIONS
Owner's Manual
02 Series Electronic Flowmeter
with Scaled Pulse Output
IMPORTANT NOTICE
This meter is not approved for use with ammable liquids.
Do not use with liquids or chemicals that are not compat-
ible with the wetted materials found in the Specications
section.
This meter is not legal for trade applications.
This meter is sensitive to electrical "noise" and may not op-
erate correctly if located near certain electrical equipment.
CALIBRATION
This meter has a permanent factory calibration for light
viscosity uids. If installed and used correctly, accuracies of
no greater than ±5% will be obtained.
INSTALLATION
This meter may be installed in-line either horizontally or
vertically, or at the end of the hose adjacent to the nozzle
if present. For best accuracy, provide 10 inches of pipe
upstream and 5 inches of pipe downstream. The use of pipe
sealant or PTFE tape is acceptable. Review your application
for suitability. Attach meter with arrow on outlet port pointed
in the direction of ow.
For Aluminum Housings: Using a wrench, tighten meter at
the ends.
For Nylon Housings: Hand tighten only. Avoid using metal
connections, as this could damage the housing.
OPERATION
Batch and Cumulative Totals
This meter maintains two totals: Batch and Cumulative.
The Batch total may be reset to measure ow during a
single use. The Cumulative total provides continuous mea-
surement and may not be manually reset. The Batch total is
labeled TTL1. The Cumulative total is labeled TTL2. When
the Cumulative total reaches a maximum reading of 9999,
it will automatically reset to zero. Press the DISPLAY button
briey to switch between Batch and Cumulative totals.
Activate the Meter
Turn the meter ON by starting uid ow or briey pressing
the DISPLAY button. The meter will display the batch or
cumulative total from last use.
Press DISPLAY briey to display the batch total. Hold the
DISPLAY button down for three seconds to reset that batch
total to zero.
This meter is programmed to turn off automatically if not
used for approximately one minute.
Scaled Output Pulse
For every whole unit (Gallon or Litre) that passes through the
meter's Batch Total (TTL1), a single pulse is transmitted via
the attach cable. The White wire is signal and the Black wire
is common (GND) (See Specications).
Note: Some interface devices may not have an internal pull-
up resistor. Use a minimum 820 ohms resistor if necessary
(See Figure 1).
Batteries Included
Figure 1
CUSTOMER
INTERFACE
EQUIPMENT
5-30 VDC
- PULSE
BLACK - COMMON GND
INPUT
V+
PULL-UP
RESISTOR
WHITE
FIG. 1
2
920894-01 Rev. C
MAINTENANCE
Proper handling and care will extend the life and service of
this meter.
Turbine Rotor
This meter is virtually maintenance-free. However, it is
important for the rotor to move freely. Keep the meter clean
and clear of contaminants.
Remove debris or deposits from the rotor using a soft brush
or small probe. Be careful not to damage the turbine rotor or
supports.
Blowing compressed air through the turbine assembly
could damage the rotor.
CAUTION
BATTERY REPLACEMENT
The meter is powered by two AAA alkaline batteries which
may be replaced while the meter is installed. When batteries
are removed or lose power, the batch and cumulative totals
reset to zero but the factory calibration is retained.
If the meter display becomes dim or blank, replace the bat-
teries as follows:
1. Remove the four Phillips-head screws from the face of
the meter and lift the faceplate from the turbine.
2. Remove the old batteries and clean any corrosion from
the terminals.
3. Install new batteries. Make sure the positive post is in
the correct position.
4. When the batteries are replaced, the faceplate will power
ON. Check the display to ensure normal functions have
resumed before assembling again.
5. Re-seat batteries, if necessary, and position the face-
plate on the turbine housing. To avoid moisture dam-
age, make sure the seal is fully seated. Tighten the four
screws on the faceplate.
SERVICE
For technical assistance, warranty replacement or repair
contact your FLOMEC® distributor:
To obtain prompt, efficient service, always be prepared
with the following information:
• The model number
• The manufacturing date code (located under the
coverplate)
For warranty work, always be prepared with your original sales
slip or other evidence of purchase date.
Please contact your FLOMEC® distributor before returning
any part. It may be possible to diagnose the trouble and nd
a solution with a telephone call. You may also be informed of
any special requirements you will need to follow for shipping.
SPECIFICATIONS
02 N 31 GM
02 - Series Flowmeter
A - Aluminum Housing
N- Nylon Housing
12 - 1” BSPT (Female)
31 - 1” NPT (Female)
52 - 1” BSPP (Female)
GM - Gallons
LM - Litres
Flowrate: 3 to 30 GPM
(11 to 113 LPM)
Working Pressure (MAX.): 150 PSIG (10.3 bar) Nylon
300 PSIG (21 bar) Aluminum
Operating Temperature: +14F to +130F
(-10C to 55C)
Storage Temperature: -40F to +158F
(-40C to 70C)
Wetted Materials:
Housing:
Noted above
Bearings:
Ceramic
Shaft:
Tungsten Carbide
Rotor / Supports:
Nylon
Rings:
316 Stainless Steel
Signal Generator:
Ferrite
Pulse Out Description: Open Collector (a.k.a. npn
or current sinking)
Pulse Duration: 250 msec
Pulse Amplitutde: 5 to 30 VDC
Scaling: One pulse per
Gallon or Litre
Cable Length: 5 ft. / 1.5 meters
The Waste Electrical and Electronic
Equipment (WEEE) directive
(2002/96/EC) was approved by the
European Parliament and the Council
of the European Union in 2003. This
symbol indicates that this product
contains electrical and electronic
equipment that may include
batteries, printed circuit boards,
liquid crystal displays or other components that may be
subject to local disposal regulations at your location.
Please understand those regulations and dispose of this
product in a responsible manner.
3
920894-01 Rev. C
Printed in USA 03/15 Rev.- 920895-01
Declaration of Conformity
Manufacturer's Name: Great Plains Industries, Inc.
Manufacturer's Address: 5252 East 36th Street North
Wichita, KS USA 67220-3205
Declares, that the product:
Product Name: Electronic Digital Meter
Model Numbers: 02A12LM, 02N12LM, 02A31GM,
02N31GM, 02A31LM, 02N31LM,
and 02A52LM
Conforms to the following Standards:
EMC: EN 50081-1 : 1992 (Reference EN 55022)
EN 55082-1 : 1992
Supplementary Information:
- e products comply with the requirements of the EMC Directive 89/336/EEC.
- e products conform to Council Directive 2011/65/EU and 2002-95-EC as amended (RoHS Directive)
relating to the restriction of certain hazardous substances in electrical and electronic equipment.
- is product is not recommended for custody transfer or application where levying by consumption takes
place.
- is product has insucient internal volume size or pressure ratings to meet a pressure directive.
- Year of Manufacturing is displayed directly on the product as Manufacturing Date Code (Mfg. Date)
indicating week and year.
I the undersigned, hereby declare that the equipment specied above conforms to the above Directive(s) and
Standard(s).
Signature:
Full Name: Victor Lukic
Position: President
Great Plains Industries, Inc.
Place: Wichita, KS USA
April 2014
920894-01 Rev. C09/15
© 2015 Great Plains Industries, Inc. All Rights Reserved.
© 2015 Great Plains Industries, Inc. All Rights Reserved.

This manual suits for next models

11

Other GPI Measuring Instrument manuals

GPI FM-300H User manual

GPI

GPI FM-300H User manual

GPI 01N31GM User manual

GPI

GPI 01N31GM User manual

GPI M30-G8N User manual

GPI

GPI M30-G8N User manual

GPI LM-200 User manual

GPI

GPI LM-200 User manual

GPI 09 COMPUTER ELECTRONICS User manual

GPI

GPI 09 COMPUTER ELECTRONICS User manual

GPI 01N31GM-U User manual

GPI

GPI 01N31GM-U User manual

GPI FM-100 Series User manual

GPI

GPI FM-100 Series User manual

GPI FM-300HR User manual

GPI

GPI FM-300HR User manual

GPI M30-G6N User manual

GPI

GPI M30-G6N User manual

GPI MR 5-30 User manual

GPI

GPI MR 5-30 User manual

GPI 01A Series User manual

GPI

GPI 01A Series User manual

GPI TM Series User manual

GPI

GPI TM Series User manual

GPI 01A Series User manual

GPI

GPI 01A Series User manual

GPI MR 5-30 Series User manual

GPI

GPI MR 5-30 Series User manual

GPI FLOMEC QM Series User manual

GPI

GPI FLOMEC QM Series User manual

GPI 01N31GM User manual

GPI

GPI 01N31GM User manual

GPI FM-300H User manual

GPI

GPI FM-300H User manual

GPI GM Series User manual

GPI

GPI GM Series User manual

GPI 01A Series User manual

GPI

GPI 01A Series User manual

GPI QME10 User manual

GPI

GPI QME10 User manual

GPI GPI-122 User manual

GPI

GPI GPI-122 User manual

GPI 03 Series User manual

GPI

GPI 03 Series User manual

GPI GM Series User manual

GPI

GPI GM Series User manual

GPI 01A31GM User manual

GPI

GPI 01A31GM User manual

Popular Measuring Instrument manuals by other brands

TANEL Electronics WIP-22D user manual

TANEL Electronics

TANEL Electronics WIP-22D user manual

EMIS EMIS-VIHR 200 Operation manual

EMIS

EMIS EMIS-VIHR 200 Operation manual

LogikaControl HTR Installation and use manual

LogikaControl

LogikaControl HTR Installation and use manual

Asclepion QuadroStar 532/980 user manual

Asclepion

Asclepion QuadroStar 532/980 user manual

Campbell CMP3 instruction manual

Campbell

Campbell CMP3 instruction manual

ICM Controls ICM450 Installation, operation & application guide

ICM Controls

ICM Controls ICM450 Installation, operation & application guide

Polimaster PM1710A Operation manual

Polimaster

Polimaster PM1710A Operation manual

PCB Piezotronics IMI Sensors 604B32 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI Sensors 604B32 Installation and operating manual

Renishaw Primo Radio Part Setter installation guide

Renishaw

Renishaw Primo Radio Part Setter installation guide

Endress+Hauser PROFIBUS PA Proline Promass 80 operating instructions

Endress+Hauser

Endress+Hauser PROFIBUS PA Proline Promass 80 operating instructions

Endress+Hauser Proline Prosonic Flow P 500 operating instructions

Endress+Hauser

Endress+Hauser Proline Prosonic Flow P 500 operating instructions

Endress+Hauser Proline 500 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline 500 Brief operating instructions

Primus TIM-94N user manual

Primus

Primus TIM-94N user manual

ATAGO PAL-41S instruction manual

ATAGO

ATAGO PAL-41S instruction manual

Stack Clubman ST200 manual

Stack

Stack Clubman ST200 manual

Callaway 350TL user manual

Callaway

Callaway 350TL user manual

SICK WebChecker MLG-2 quick start guide

SICK

SICK WebChecker MLG-2 quick start guide

ELECTOR MINIgarde operating manual

ELECTOR

ELECTOR MINIgarde operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.