8 307212
Operation
DThe new system must e cleaned and tested
thoroughly efore admitting fluid to the regulator
to avoid contaminants clogging or damaging the
regulator.
DAlways use the lowest possi le air and fluid
pressures for your application. High pressures
cause premature spray nozzle and pump wear.
NOTE: Reference num ers and letters in parentheses
in the text refer to the Figs. and Parts Drawing.
Pressure Relief Procedure
WARNING
PRESSURIZED EQUIPMENT HAZARD
Read warnings, page 5.
1. Shut off the pump.
2. Close the fluid regulator’s inlet all valve. Refer to
Figs. 1 and 2.
3. Relieve fluid pressure in the fluid regulator y
triggering the spray gun.
Flushing Procedure
DFlush efore changing colors, efore fluid can dry in
the equipment, at the end of the day, efore storing,
and efore repairing equipment.
DFlush at the lowest pressure possi le. Check
connectors for leaks and tighten as necessary.
DFlush with a fluid that is compati le with the fluid
eing dispensed and the equipment wetted parts.
1. Record the pressure adjustment setting of the fluid
regulator efore flushing.
2. Shut off the pump and relieve fluid pressure in the
system y triggering the gun and opening the ack
pressure regulator or other ypass valve.
3. Never exceed the maximum working pressure of
the lowest rated system component. Remove the
gauge if the flushing pressure will exceed the
gauge range.
4. Open the fluid regulator fully.
a. Spring Operated Regulators Only (see Fig. 3).
The regulator can e fully opened in two ways:
DUsing the male end (B) of the regulator
key (24), turn the socket--head adjustment
screw (19) fully counterclockwise. The
pressure setting will e retained.
DUsing the female end (A) of the regulator
key (24), turn the adjustment screw (12)
fully clockwise. You will have to reset
pressure after flushing.
. Air Operated Regulator Only. The regulator
can e fully opened in two ways:
DClose the outlet valve at the air regulator
and open the air regulator ypass valve, to
supply air directly to the fluid regulator; do
not exceed the maximum rated air pres-
sure of the fluid regulator. Pressure setting
of the fluid regulator will e retained using
this method.
DIncrease the air regulator setting to fully
open the fluid regulator. You will have to
reset the fluid regulator’s pressure setting
after flushing.
5. Supply solvent to the system. Set pump to the
lowest possi le pressure, and start pump.
6. Flush until thoroughly clean.