
IX
CONTENTS
Shortlinesegmentsettings............................................ 3-17
Setting the Quality [QUALITY].......................................... 3-18
Thick Mode Settings ................................................. 3-18
Perforation Settings.................................................. 3-19
3.8 Running a Cutting Test.................................................3-21
CutterPenTest.....................................................3-21
Creasing Tool Test...................................................3-21
Cutting a sample ....................................................3-22
BladeLengthAdjustment .............................................3-23
3.9 Media and Cutting Conditions ...........................................3-24
3.10 Setting the Cutting Origin...............................................3-25
3.11 Using the Copy Function ...............................................3-26
3.12 Using the Hold Function................................................3-29
CH 4 REGISTRATION MARK SETTINGS AND DETECTION
4.1 OutlineoftheRegistrationMarkFunction ...................................4-2
4.2 Setting the Registration Mark Mode........................................4-3
4.3 Setting the Registration Mark Pattern ......................................4-5
Setting the Registration Mark Spacing (FC4510-60only)..........................4-6
Setting the Center Registration Mark (FC4510-60only)...........................4-6
4.4 RegistrationMarkDistanceAdjustment.....................................4-8
USER (ManualInput)........................................................4-8
CUSTOM...........................................................4-9
4.5 Setting the Registration Mark Size........................................ 4-10
4.6 Setting the Registration Mark Offset ...................................... 4-11
4.7 Adjusting the Registration Mark Sensor.................................... 4-12
Adjusting the Registration Mark Sensor
by Using a Pre-printed Cross Symbol and a Plotted Cross Symbol ........... 4-12
Adjusting the Registration Mark Sensor
by Using One Plotted and One Cut Cross Symbol ........................ 4-13
4.8
SettingtheRegistrationMarkDetectionJudgmentLevel...........................4-16
AutomaticAdjustmentoftheSensitivityoftheRegistrationMarkSensor......... 4-17
Adjusting the Sensitivity of the Registration Mark Sensor..................... 4-18
4.9 Setting the Registration Mark Detection Speed ..............................4-20
4.10 Setting the Number of Detection Operations ................................4-21
4.11 Setting the Sensing Interval .............................................4-23
4.12 Axis Adjustment ......................................................4-24
4.13 Registration Mark Detection.............................................4-26
Manual Detection ...................................................4-27
4.14 Setting the Registration Mark Cutting Function ..............................4-29
4.15
SettingtheRegistrationMarkDetectionStartPosition...........................4-31
CH 5 FUNCTION SETTINGS AND OPERATIONS
5.1 PAUSE Menu Configuration..............................................5-2
5.2 Clearing the Buffer .....................................................5-3
5.3 Raising/Lowering the Tool ...............................................5-4