OM-HY-6E
4
The HY-6E has two independent cavities, each
with its own base-mounted steam generator.
(New model shown)
Equipment Description
Your Groen HY-6E HyPerSteam Convection Steamer is
designed to give years of service. It has two stainless
steel cavities (cooking chambers) which are served by
twin, independent atmospheric steam generators which
are electrically-heated. A powerful blower circulates the
steam in each cavity to increase heating efficiency.
Each cavity holds up to three steam table pans (12" x 20"
x 2½"). An 18 gauge stainless steel case encloses the
cavities, the steam generators and the control
compartment that houses electrical components. Door
hinges are reversible (the doors may be set to open from
the left or right). Operating Controls are on the front
panel.
HY-6E steamers are equipped with fully electronic
controls and a button-activated, preprogrammed CLEAN
cycle. The On-Off switch is a touch pad control, and the
distinctive symbol for steam is integrated into the panel
design.
The drain system includes a spray condenser, which
helps keep steam from escaping down the condensate
drain.
Water Conditioning
It is essential to supply the steam generator with water
that will not form scale. Even though the steam
generator/boiler is engineered to minimize scale
formation, scale development depends on the
hardness of your water and the number of hours you
operate the equipment each day.
Most water supplies contain minerals which form scale.
It is this scale which could lead to an early component
failure.
Your local water utility can tell you about the minerals
in your water. The water going to the steam generator
should have between 30 and 40 parts per million (ppm)
total dissolved solids (TDS) and should have a pH
(acidity rating) of 7.0 to 9.0. Please follow these
simple precautions:
1. The best way to prevent scale is to use a Groen
PureSteem™ Water Treatment System which has
been specifically designed for Groen steamers and
combination ovens. Do not rely on unproven
water treatment systems sold for scale
prevention and removal. They are not
specifically designed to work with Groen
steamers and combination ovens.
2. A well-maintained water treatment system and a
regular cartridge replacement schedule is
essential.
3. Using a Groen PureSteem™ Water Treatment
System will provide longer steam
generator/boiler life, higher steam capacity, and
reduce maintenance requirements.
4. If you notice a slowdown in steam production or
an increase in deliming, have the steamer
checked for scale build-up. This could be an
indication that the water treatment cartridges
need replacing. Heavy scale reduces the unit’s
ability to boil water, and can even cause
component failure.
MINIMIZE SCALE PROBLEMS BY INSTALLING
AND MAINTAINING A GROEN PureSteem™
WATER TREATMENT SYSTEM AND BY
DELIMING THE STEAMER REGULARLY.
The Groen HY-6E Steamer features two separate
water inlets — one for the steam generator/boiler
(treated water), the other for the spray condenser
(untreated water). The second intake will reduce
treatment requirements resulting in significant
savings.
The dual water connections are side by side on the
rear of the unit. When seen from the back of the