Wiring Diagram with Slave Reader
12V Linear
Power supply Door Exit Button
0V
Door Contact
0V
Common the OV from the
Fire Alarm Panel and the OV
from the Door Control to
avoid any ground loop issues.
Fire Alarm
Panel
0V
When the fire alarm
is activated (0V removed
from IP4) the door will
be opened
12V Sounder
6Wiring Diagrams
12V
0V
NO
COM
NC
12 - 24 VAC
12 - 24 VAC
Wiring for StikeLock only
using 12 - 24VAC supply
Note: All OV shown in the diagram are connected to OV of the Door Control.
0V
IP5
Break
Glass
OP1
Data1/
Clock
IP3
Data0/
Data
IP4
Fire Alarm
IP2
Door
Contact
IP1
Door Exit
Button
OP2
Alarm/Sounder
12V DC
Only
0V
Note: Fire Alarm Override is
deactivated until the Door
Control joins a network.
12V
Dual-Pole
Ressetable
BreakGlass Unit
0V
Pole to cut
power to Lock
Pole for
Monitoring
Unit
NC
0V
COM
NO
Suggested Wiring
for BreakGlass
Unit above.
Common the OV from the Door
Control and the COM on the
Controllers “Door Network”
when using the 485 interface
Place a 120ohm Termination
Resistor across A & B at the
Controller and across the last
Door Control in the daisy chain
A B
485 Network
Connections
Volt-Free
Tamper
Contacts
T1 T2
Smart Slave
(See page 14 for detailed
wiring diagram)
IP6
External
Tamper
Input
Max Cable Length
- 100m Shielded Cable
OP3
Follow
Relay
7
Wiring Diagrams
12V Linear
Power supply Door Exit Button
0V
Door Contact
0V
Common the OV from the
Fire Alarm Panel and the OV
from the Door Control to
avoid any ground loop issues.
Fire Alarm
Panel
0V
When the fire alarm
is activated (0V removed
from IP4) the door will
be opened
12V Sounder
12V
0V
NO
COM
NC
12 - 24 VAC
12 - 24 VAC
Wiring for StikeLock only
using 12 - 24VAC supply
Note: All OV shown in the diagram are connected to OV of the Door Control.
0V
IP5
Break
Glass
IP4
Fire Alarm
IP2
Door
Contact
IP1
Door Exit
Button
OP2
Alarm/Sounder
12V DC
Only
0V
Note: Fire Alarm Override is
deactivated until the Door
Control joins a network.
12V
Dual-Pole
Ressetable
BreakGlass Unit
0V
Pole to cut
power to Lock
Pole for
Monitoring
Unit
NC
0V
COM
NO
Suggested Wiring
for BreakGlass
Unit above.
Common the OV from the Door
Control and the COM on the
Controllers “Door Network”
when using the 485 interface
Place a 120ohm Termination
Resistor across A & B at the
Controller and across the last
Door Control in the daisy chain
A B
485 Network
Connections
Volt-Free
Tamper
Contacts
T1 T2
IP6
External
Tamper
Input
Wiring Diagram with Intruder Alarm Panel
Arm Alarm Input
Arm Output (N/O)
Intruder Alarm
Panel
OP3
Follow
Relay