2Technical Specifcation
Power Supply 12V DC
Current consumption 70mA
Current consumption with load (max) 100mA
Relay Contact Rating 5 Amps /240V ac
Operating Temperature -20 C to +60 C
Moisture Resistance IP 67
Max Data Cable Length - ( Shielded ) 100m
Dimensions - Flush Mount W. 87mm D. 21mm H. 119mm
- Surface Mount W. 87mm D. 35mm H. 119mm
Technical Specs
Adding a Programming Card
AnyCard
x 2
Step Description
1 Remove security caps and power down unit.
Power up unit and Present Any Card 2 times
2 immediately. This card is now the Programming
Card for the unit. Refit security caps
Default Data Output Format
The Default Data Output Format is set to Clock and Data Format
On power-up the Data Output Format can be determined by the number of beeps:
- 1 beep = Wiegand 26 bit Format
- 2 beeps = Wiegand 34 bit Format
- 3 beeps = Clock and Data Format
The Data Output Format can be changed by following instructions on page 3.
3
Output Format
Output Data Format - Wiegand 26 bit
Step Description
1 Present Programming Card 1 Time
2 Present Any Card once
Programming
Card x 1
AnyCard
x 1
Output Data Format - Wiegand 34 bit
Step Description
1 Present Programming Card 2 Times
2 Present Any Card once
Programming
Card x 2
AnyCard
x 1
Output Data Format - Clock and Data
Step Description
1 Present Programming Card 3 Times
2 Present Any Card once
Programming
Card x 3
AnyCard
x 1