30301837 Issue 1.05
Features
Built-in microprocessor samples and collects
data in real time.
Rate of rise and fixed temperature alarm mode.
Standard: UL 521.
Description
C-9103(UL) Conventional Rate of Rise and Fixed
Temperature Heat Detector (the detector) is
non-addressable. With built-in microprocessor, it is
fixed with highly reliable fire judging program and
works stably.
When the detector checks fire signal, it can change its
own current to transmit fire signal to control panel or
interface module. The detector keeps illuminating fire
LED to indicate fire status until resetting. Used
together with P-9907 Active End of Line Unit (AEOL),
it can connect with compatible fire alarm control panel
to conduct the processing of detector signals.
Connections and Wiring
The orientation base is shown in Fig. 2.
C
Record Label
0
Mounting Hole
3
B
-
Z
D
A
Fig. 1 Fig. 2
The bottom and orientation base of the detector are
shown in Fig.1 and 2. There are four terminals with
numbers on the base, “1” connects with the anode of
the output end of compatible controller, “2” connects
with the power anode of the next detector as output
(terminal No. “1”), “3” connects with the power
cathode of the next detector (terminal No. “3”) and the
cathode of the output end of compatible controller, “4”
doesn’t connect to any wires but is used to fix the
detector accessorily.
Recommended Wiring:
1.0mm2 or above fire cable for all terminals, laid
through metal conduit or flame-proof conduit, subject
to local codes.
Installation
There are location elements on the detector and the
orientation base to ensure there is only one installing
position. There are twomarks on pointA and B of the
orientation base, and a mark on point C of the side
face of bottom of the detector. When installing,
aligning the mark C of the detector to point A of the
orientation base, rotate the detector clockwise to point
B, then the detector is installed.
Mounting of the detector is shown in Fig. 3.
Detector
Orientation Base
Wiring Tube
Embedded Box
Fig. 3
Application
Warning: The detector should be connected with
fire alarm control panel or other devices with
current limit function. Otherwise the detector may
be destroyed by too heavy alarm current.
A 4.7k/1w terminal resistor can be connected
between terminal “2” and “3” of the last base in a loop.
System connection is shown in Fig. 4.
Output-
Output+
Compatible
Controller
DZ-03 Base
4.7k
Terminal
Resistor
DZ-03 Base
CAUTION: DO NOT USE LOOPED WIRE UNDER TERMINAL 3. BREAK WIRE
RUN TO PROVIDE SUPERVISION OF CONNECTIONS.
Fig. 4
Maintenance
1. Before installation, the detector should be kept well
and adopted the corresponding measures for
dust-proof, damp-proof and corrosion-proof.
2. The dust cover cannot be removed until the project
has been plunged into usage.
3. The detector should be cleaned at least once each
year.
4. Before cleaning, notify relative departments that
the system is undergoing maintenance and will be out
C-9103(UL)
Conventional Rate of Rise
and Fixed Temperature Heat Detector
30301837 Issue 1.05
of service. Disable the zone or system in
maintenance to avoid unwanted alarms.
5. After cleaning, install the detector back and test
again. Notify relative departments that the system is
back into operation.
6. Do fire simulation test every half a year to make
sure the detector works normally.
Specification
Operating Voltage
12VDC~28VDC
Standby Current
≤60μA
Alarm Current
≤30mA
Initiating Time:
≤10s
Alarm Reset:
Instantaneous Cut out (5s
MAX, 2.5VDC MAX)
Alarm Confirming
LED
Red, not lit when in normal
operation, constantly lit
when alarming
Maximum Ripple
Voltage
4V(peak-to-peak value)
Sensitivity
Fixed Temperature
Setpoint:135℉(57℃)
Rate of Rise Detection:
15℉/min (8.3℃/min)
Wiring
Connecting with the power
cable by polarized two-wire
Ingress protection
Rating
IP33
Ambient
Temperature
32℉(0℃)~100℉(37.8℃)
(UL 521)
Relative Humidity
≤95%, non condensing
Material and Color
of Enclosure
ABS, white (RAL 9010)
Dimensions
Diameter: 100mm
High: 45mm (without base)
Mounting Hole
Spacing
45mm~75mm
Weight
About 120g
Accessories and Tools
Module
Name
Remarks
DZ-03
Orientation base
Supplied separately
Limited Warranty
This detector is approved by UL as a recognized
component. It’s strongly recommended that fire alarm
control panel manufacturers intending to use this
detector in their fire alarm systems to verify system
compatibility before application in order to avoid
system failure.
GST warrants that the product will be free from defects
in design, materials and workmanship during the
warranty period. This warranty shall not apply to any
product that is found to have been improperly installed
or used in any way not in accordance with the
instructions supplied with the product. Anybody,
including the agents, distributors or employees, is not
in the position to amend the contents of this warranty.
Please contact your local distributor for products not
covered by this warranty.
This Data Sheet is subject to change without notice. Please contact GST for more information or questions.
Gulf Security Technology Co., Ltd.
No. 80, Changjiang East Road, QETDZ, Qinhuangdao, Hebei, P. R. China 066004
Tel: +86 (0) 335 8502434 Fax: +86 (0) 335 8502532
service.gst@fs.utc.com www.gst.com.cn

Other GST Security Sensor manuals

GST DI-9104Exd User manual

GST

GST DI-9104Exd User manual

GST D-9107RExd User manual

GST

GST D-9107RExd User manual

GST DC-M9103 User manual

GST

GST DC-M9103 User manual

GST DI-9104Exd User manual

GST

GST DI-9104Exd User manual

GST D-9105RExd User manual

GST

GST D-9105RExd User manual

GST DI-9103E User manual

GST

GST DI-9103E User manual

GST DC-9103E User manual

GST

GST DC-9103E User manual

GST I-9406 User manual

GST

GST I-9406 User manual

GST DC-9101(Ex) User manual

GST

GST DC-9101(Ex) User manual

GST DI-M9103 User manual

GST

GST DI-M9103 User manual

GST DC-M9103 User manual

GST

GST DC-M9103 User manual

GST DC-9103E User manual

GST

GST DC-9103E User manual

GST DC-9103 User manual

GST

GST DC-9103 User manual

GST C-9103 User manual

GST

GST C-9103 User manual

GST DC-9104Exd User manual

GST

GST DC-9104Exd User manual

GST GST-AS-200 User manual

GST

GST GST-AS-200 User manual

GST DI-9103 User manual

GST

GST DI-9103 User manual

GST DI-9103 User manual

GST

GST DI-9103 User manual

GST R6602 User manual

GST

GST R6602 User manual

GST DC-9103 User manual

GST

GST DC-9103 User manual

GST C-9105R User manual

GST

GST C-9105R User manual

GST I-9101 User manual

GST

GST I-9101 User manual

GST DC-9105E User manual

GST

GST DC-9105E User manual

GST I-9106 User manual

GST

GST I-9106 User manual

Popular Security Sensor manuals by other brands

Optex AX-100TFR Series installation instructions

Optex

Optex AX-100TFR Series installation instructions

Interlogix Kalatel 600-9400-IMAG installation guide

Interlogix

Interlogix Kalatel 600-9400-IMAG installation guide

Bornack Stripe Comfort Click user manual

Bornack

Bornack Stripe Comfort Click user manual

BEMKO SES15BL instructions

BEMKO

BEMKO SES15BL instructions

Yale AC-OPIR manual

Yale

Yale AC-OPIR manual

Siemens SICAM V01.00 manual

Siemens

Siemens SICAM V01.00 manual

RKI Instruments 35-3010RKA-04 manual

RKI Instruments

RKI Instruments 35-3010RKA-04 manual

HIOTH TECHNOLOGY CO., LTD CT-SMEA2001-ID user manual

HIOTH TECHNOLOGY CO., LTD

HIOTH TECHNOLOGY CO., LTD CT-SMEA2001-ID user manual

Visonic NEXT PLUS Series installation instructions

Visonic

Visonic NEXT PLUS Series installation instructions

LEGRAND Bticino MyHOME 3518MW instructions

LEGRAND

LEGRAND Bticino MyHOME 3518MW instructions

urmet domus 1051 Installation, programming and functions manual

urmet domus

urmet domus 1051 Installation, programming and functions manual

Uni-Trend UT12B operating manual

Uni-Trend

Uni-Trend UT12B operating manual

Diablo DSP-20-LV user manual

Diablo

Diablo DSP-20-LV user manual

XP DEUS II quick start

XP

XP DEUS II quick start

Omron F3SJ-E0185P25 user manual

Omron

Omron F3SJ-E0185P25 user manual

ATD Tools ATD3698 user manual

ATD Tools

ATD Tools ATD3698 user manual

schmersal BNS 40S operating instructions

schmersal

schmersal BNS 40S operating instructions

United Safety Incorporated Voltek NS user guide

United Safety Incorporated

United Safety Incorporated Voltek NS user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.