30303705 Issue 3.04
Features
Reusable button, that can be reset manually;
Providing an independent output contact;
Plug-in structure.
Description
C-9201 (Ex) Explosion Proof Manual Call Point (MCP)
is installed in public places. When there is a fire,
pressing the nearest MCP, alarm signal can be sent to
the fire alarm control panel (FACP). And the control
panel will show the code of I-9332 Interface
connecting with the MCP, and give alarm sound.
The MCP is operated by pressing the mechanically
latched button to reduce possibility of accidental alarm.
There is a LED on the MCP, which is used to indicate
its status.
Connection and Cabling
Terminals of the MCP are shown in Fig.1.
Cable
Entry
Mounting
Hole
Mounting
Hole
65mm
Fig.1
Connection:
I1, I2: Connecting to intrinsically safe side of the
Safety Barrier
K1, K2: Normally open output terminals
O1, O2: Connecting to the next MCP
Recommended Wiring: Selecting intrinsically safe cable
with cross section not less than 1.0mm2 , and the
capacity assigned among cables should not be over
0.04μF, the inductance assigned not over 4.3mH. All
wiring must be installed in compliance with the local
codes.
Installation
Unplug the MCP, thread the cable through the cable
entry of the base box and connect it to corresponding
terminals, and plug the MCP back. The base of the
MCP can be surface or flush mounted as shown in
Fig.2 and Fig.3.
MCP Conduit Back Box
MCP
Back Box
Conduit
Fig.2 Fig.3
Warning: Before installing the MCP, disconnect the
power from the loop and verify that all bases are
securely installed and that the wiring polarity is
correct at each base.
C-9201(Ex)
Explosion Proof Manual Call Point
30303705 Issue 3.04
Application
Explosion Proof Manual Call Point is intrinsically safe,
which is designed for flammable and explosive locations,
such as petroleum and chemical industry. When the
MCP is connected with I-9332 Interface, explosion-proof
photoelectric smoke detector, and explosion-proof rate
of rise and fixed temperature heat detector in series, a
4.7kΩterminal resistor should be connected to the end
of the output loop. Its system wiring is shown in Fig.4.
Safety Area
2
13
4
Hazardous Area
Explosion-proof
Detector
D
Z
-
0
3
K1 K2
D
Z
-
0
3
D
Z
-
0
3
I2
I1
O2 O1
Explosion-proof
Manual Call Point Explosion-proof
Detector
4.7kΩend-of-line resistor
Explosion-proof
Detector
Z2
O+
O-
D1
D2
Z1
I-9332 Interface
Zener Barrier
Circuit Board
Fig.4
Notes:
The total number of explosion proof detectors
and explosion proof manual call point to be
installed should not be over 10.
Never carry out maintenance in field with power
on. Please operate according to corresponding
regulations.
Products passed the explosion-proof test should
not be replaced; furthermore, the components
and the structure which would affect
explosion-proof performance should not be
modified without authorization.
Specification
Operating Voltage
24VDC (12VDC~28VDC)
Standby Current
0mA
Alarm Current
≤30mA
Fire LED
Red, illuminate when alarming
Output Capacity
Rating 60VDC/100mApassive
output contact signal, contact
resistance ≤100mΩ
Type of Initiating
Part
Reusable
Initiating Mode
Pressing the glass manually
Reset Mode
Manually reset by a sucker
Explosion-proof
Marking
ExibIICT6
Output
Parameters of
Safety Barrier
Uo=28V, Io=93mA
Wiring
Two wire
Ingress Protection
Rating
IP40
Environment
Temperature
-20℃~+40℃
Relative Humidity
≤95%, no condensing
Material and Color
of Enclosure
ABS, Red (PANTONE 185C)
Dimension
90mm×122mm×48.5mm
Mounting Hole
Spacing
65mm
Weight
221g (with base)
Limited Warranty
GST warrants that the product will be free of charge
for repairing and replacing from defects in design,
materials and workmanship during the warranty period.
This warranty doesn’t cover any product that is found
to have been improperly installed or used in any way
not in accordance with the instructions supplied with
the product. Anybody, including the agents,
distributors or employees, is not in the position to
amend the contents of this warranty. Please contact
your local distributor for products not covered by this
warranty.
This Data Sheet is subject to change without notice. Please contact GST for more information or questions.
Gulf Security Technology Co., Ltd.
No. 80, Changjiang East Road, QETDZ, Qinhuangdao, Hebei, P. R. China 066004
Tel: +86 (0) 335 8502434 Fax: +86 (0) 335 8502532
service.gs[email protected]tc.com www.gst.com.cn

Other GST Security Sensor manuals

GST DC-9101(Ex) User manual

GST

GST DC-9101(Ex) User manual

GST DC-9103 User manual

GST

GST DC-9103 User manual

GST C-9103 User manual

GST

GST C-9103 User manual

GST DC-9103E User manual

GST

GST DC-9103E User manual

GST I-9101 User manual

GST

GST I-9101 User manual

GST DC-9103E User manual

GST

GST DC-9103E User manual

GST I-9105R User manual

GST

GST I-9105R User manual

GST DI-9104Exd User manual

GST

GST DI-9104Exd User manual

GST DI-9103E User manual

GST

GST DI-9103E User manual

GST DC-M9103 User manual

GST

GST DC-M9103 User manual

GST DI-M9103 User manual

GST

GST DI-M9103 User manual

GST C-9105R User manual

GST

GST C-9105R User manual

GST DI-9103 User manual

GST

GST DI-9103 User manual

GST DC-9103 User manual

GST

GST DC-9103 User manual

GST D-9107RExd User manual

GST

GST D-9107RExd User manual

GST DI-9104Exd User manual

GST

GST DI-9104Exd User manual

GST DI-9103 User manual

GST

GST DI-9103 User manual

GST GST-AS-200 User manual

GST

GST GST-AS-200 User manual

GST DC-M9103 User manual

GST

GST DC-M9103 User manual

GST I-9602LW User manual

GST

GST I-9602LW User manual

GST DC-9103 User manual

GST

GST DC-9103 User manual

GST I-9406 User manual

GST

GST I-9406 User manual

GST C-9103 User manual

GST

GST C-9103 User manual

GST DI-9104Exd User manual

GST

GST DI-9104Exd User manual

Popular Security Sensor manuals by other brands

System Sensor B401BR750 Installation and maintenance instructions

System Sensor

System Sensor B401BR750 Installation and maintenance instructions

Regin S65 Instruction

Regin

Regin S65 Instruction

Major tech MT405EX instruction manual

Major tech

Major tech MT405EX instruction manual

B.E.G. LUXOMAT PD4-CAS-GH manual

B.E.G. LUXOMAT

B.E.G. LUXOMAT PD4-CAS-GH manual

schmersal SRB 301AN operating instructions

schmersal

schmersal SRB 301AN operating instructions

Reer JANUS Installation, use and maintenance

Reer

Reer JANUS Installation, use and maintenance

ABB MSA-F-1.1.1-***-WL series Technical reference manual

ABB

ABB MSA-F-1.1.1-***-WL series Technical reference manual

REV Ritter JDT-08 user manual

REV Ritter

REV Ritter JDT-08 user manual

ooma Smart Security Door and Window Sensor quick start guide

ooma

ooma Smart Security Door and Window Sensor quick start guide

Sperian Miller Scorpion User instruction manual

Sperian

Sperian Miller Scorpion User instruction manual

Sminn COMPATTA CONTROL Assembly instructions

Sminn

Sminn COMPATTA CONTROL Assembly instructions

Elektrotechnik Schabus SHT 5000 operating instructions

Elektrotechnik Schabus

Elektrotechnik Schabus SHT 5000 operating instructions

Emerson ROSEMOUNT 242 instruction manual

Emerson

Emerson ROSEMOUNT 242 instruction manual

SGB VLX-S 350 M Documentation

SGB

SGB VLX-S 350 M Documentation

LEGRAND Tynetec Aidcall Big Button manual

LEGRAND

LEGRAND Tynetec Aidcall Big Button manual

Leuze electronic ERS200-M0C3-M20-HLR operating instructions

Leuze electronic

Leuze electronic ERS200-M0C3-M20-HLR operating instructions

CLAS AC 7495 manual

CLAS

CLAS AC 7495 manual

schmersal RSS 36-SD-ST-DU manual

schmersal

schmersal RSS 36-SD-ST-DU manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.