GT SONIC GT-F3 User manual

ULTRASONIC CLEANER
GT -F3
USER MANUAL
Thank you for purchasing GT SONIC ultrasonic cleaner. Please take
the time to read these operating instructions before use and retain
them for future reference. Failure to follow these instructions may
lead to serious personal injury and damage to property.

Content
01.Overview /Scope of Delivery 2
11-12
12
3-7
8-9
9-10
10-11
02.Safety Instructions
03.Introduction
04.Operation
05.Methods of Use
06.Care and Maintenance
01. OVERVIEW/SCOPE OF DELIVERY
Note:Check that all accessories are included and undamaged.
2
1. Transparent lid
4. Housing
2. SUS304 tank
8. Unit base
5. Timer display
3. Logo
6. Control panel
7. Basket
1
7
4
5
6
8
2
3

02. SAFETY INSTRUCTIONS
Intended use
The cleaner is designed for private home use only and must not be
used for commercial purposes.
The cleaner must only be used indoors.
Possible misuse
The cleaner must only be used according to the purposes described
in these instructions.
DANGER for children
//This cleaner is not intended to use by individuals with restricted
physical sensory or metal capacities or those with lack of experience
or knowledge, include children, unless they are supervised by an
individual who is responsible for their safety or have received training
in operating the cleaner .
//Cleaning and maintenance shall not be carried out by children
//Store the cleaner and accessories where it is not reachable by children.
//Children must not play with packaging material.
//Do not allow children to play with bags; Danger of suffocation.
without supervision.
3

DANGER of electric shock as a result of moisture
//Do not use this cleaner in the vicinity of bathtubs,showers,washbasins
or other vessels containing water.
//Never put the cleaner down in such a way that it could fall into water
//Protect the cleaner from moisture,dripping water or splash water.
//Never touch the cleaner with the wet hands.
//The cleaner ,the cable and the mains plug must not fall into water
//If the cleaner has fallen into water,pull out the mains plug immediately,
and only then remove the cleaner from the water.Do not use the
cleaner again,but have it checked by a specialist.
DANGER of electric shock
//Do not operate the cleaner if it or the cable shows visible signs
of damage or if the cleaner has been dropped.
while still connected.
or other liquids.
4
//Only connect the mains plug to a properly installed socket,which is
ieasily accessible and supplies voltage matching the rating plate. The
socketmuststillbeeasilyaccessibleafterconnection.

WARNING! Risk of material damage
//Use the original accessories only.
//Never place the cleaner on hot surfaces or near heat sources or
//Do not place the cleaner on a soft surface that might cover the openings.
5
//Ensurethatthecablenotdamagedbysharpedgesorhotsurfaces.
Donotwrapthecablearoundthecleaner(cablebreakdanger!)
//Makesurethecableisnottrappedorcrushed.
//Donotremovethegroundingprongonthelinecordplug.
//Removethemainsplugfromthesocket,whenaftereachuse,ifa
faultoccurs,whenyouarenotusingthecleaner,beforecleaningthe
cleanerandduringthunderstorms.
//Toavoidanyrisk,donotmakeanychangestothecleaneroraccessories.
//Donotreplacethecableyourselfeither.Repairsmustonlybe
carriedoutbyaspecializedcompany.
//Donotdisassembleyourcleaner--highvoltageinsidethecleaner
isdangerous.Exceptbyspecialist.
//Donotimmersethecleanerorpowercordinwaterorotherliquid.

//Do not operate the cleaner when the tank is empty.
Dry running will damage the cleaner.
//Do not run the cleaner for extended time or continuously .
//Do not use aggressive or abrasive cleaners.
//Do not hit the cleaner.Be careful when moving the cleaner.
//Do not expose the cleaner to temperature below -10 or above +40 .℃ ℃
CAUTION!
//No liability is assumed for scratched or damaged object.
Objects to be cleaned(application examples):
//Personal Items:Glasses,Dentures,Tooth brushes,razor blades,
not exceeded.
baby items,etc.
6
//Jewelry:Necklaces,rings,earrings,bracelets,watch chains etc.
//Metal parts:Coins,medals,badges,valves ,etc.

CAUTION!
Loosely framed stones,glued ornaments on decorative items as well
as loose items could be detached during the cleaning process.Ask
your dentist particularly in case of dentures including veneers.
The following object are not suitable for ultrasonic cleaning:
//Genuine pearls,semi-precious stones,costume jewelry or soft
stones such as pearls,turquoise,coral,emeralds,etc.
//Object that can easily be discoloured,waterlogged or damaged.
//Wooden items,leather items,fabric,materials with a sensitive/
already damaged surface,electric devices,polycarbonate lenses
(thermoplastics),glasses equipped with coated plastic lenses(even
the smallest damage to the surface layer may result in irreparable
//Mobile phones,watches,glass frames or artworks made from
damages to the material).
tortoiseshell or abalone.
Cleaning detergent:
etc.that cannot be removed with water and all-purpose cleaner.
7

03. INTRODUCTION
The principle of ultrasonic cleaning
Ultrasonic cleaning is based on the cavitation effect caused by
8
the vibration of high frequency ultrasonic waves in the liquid .
Microscopic bubbles are formed.These implode causing the cavitation
SUS304 TANK
Transducer
Generator
Detergent
Tiny vibration Cavitation Debris come off
Solution
which create an intense scrubbing action on the surface of the item
being cleaned. The bubbles are small enough to penetrate microscopic
crevices, cleaning them thoroughly and consistently.

Ultrasonic cleaning is extremely effective in removing dirt and grime
which would normally require tedious manual cleaning . It is used to
clean a wide variety of instruments and mechanical parts ,returning
them to almost “brand new” condition without damage to delicate parts.
04. OPERATION
WARNING: Running cleaner without water may
2)Put the objects in the water. Be sure to exceed the 1/2
3)Close the lid, put the cleaner on the base, connect
3
1
with water.
damage cleaner!
9
2
4
level of the tank volume. The object should be
completely immersed. Do not exceed “MAX” level.
the power cord to an outlet.
4) Touch the power ON OFF button, the LED light on /
the base is green, disinfection Ultraviolet light is on.

5
6
7
10
Note: While cleaning, a buzzing sound will be
heard. This means the cleaner is working.
the power cord, open the lid and remove the
object. Finally, pour the water out of the tank.
Clean and wipe the tank.
05. METHODS OF USE
5) Touch the TIMER button , set the timing cycle
as 0-2-4-6-8 (add 2 minutes each time you touch
the current working time, when it turns to 00,
the button), the ultrasonic starts to work, and
the indicator lights up. The digital display shows
ultrasonic will stop automatically.
6)After timer and temperature setting, touch DEGAS ,
5s, and then stop for 2s, then working
quicker degassing of the cleaning liquid.
the cleaner will work in degas mode: working
Intermittent operation of ultrasonic
7 ) If you would like to stop cleaning during working
time, simply touch the power ON/OFF button again.
for 5s,…
power for a
the

Partial cleaning
3
For the partial cleaning of bigger objects,use
Do not touch the liquid during operation!
Ultra cleaning
water and repeat “Thorough Cleaning” process
4
the cleaner with its lid open.
11
2
Thorough cleaning
In order to obtain better results,you may add a
few drops of universal detergent.We recommend
using commercial dishwashing detergent-preferably
without an lipid-replenishing substances(“balm”) .
For professional cleaning purposes,special cleaning detergent can be
used.Find out which concentrate is suitable for your objects to be cleaned
and the type of contamination.
General cleaning
Use normal water for general cleaning.The object
should be completely immersed.However ,the
1
06. CARE AND MAINTENANCE
DANGER!Before cleaning the cleaner,pull out the power plug .Never
immerse the cleaner ,cable or power plug in water or another liquid
for cleaning and care purpose.
Whenitemsrequireextensivecleaning,use
untilitemscompletelycleaned.

Do not cleaning the ultrasonic cleaner with corrosive detergent or
WARNING!
pointed object.
//Use a piece of cloth to cleaning and dry the tank
//Ensure that there is no residual water left in the tank in order to
//Store the cleaner in a cool and dry place.
//Keep the cleaner out of children’s reach.
//Check the joint of the power plug and cord.
//DO not impact ,hit the cleaner. Handle with care when move the cleaner.
prevent limescale.
Model GT-F3
Ultrasonic Frequency 40 kHz
Tank Material Stainless Steel SUS304
Tank Capacity 750ml
Timer 4 timer cycles:
Power Supply AC100~120V,60Hz;
AC220~240V, 50Hz
Ultrasonic Power 35W
Tank Size 150×130×50(lxwxh)mm
Overall Size 172×198×148(lxwxh)mm
N.W. 1335g
G.W. 1665g
0min-2min-4min-6min-8min
Table of contents
Other GT SONIC Ultrasonic Jewelry Cleaner manuals