Tiny vibration Cavitation Debris come off
Generator
Transducer
SUS304 TANK Solution
Ultrasonic cleaning is based on
the cavitation effect caused by
high frequency ultrasonic wave
vibration signal in the fluid.
Microscopic bubbles are formed,
a n d t h e y i m p l o d e v i o l e n t l y
caus ing the c avi t ati on which
cr ea te a n i nt ens e s cr ubb in g
action on the surface of the item
being cleaned.The bubbles are
small enough to penetrate
microscopic crevices,cleaning
them thoroughly and consistently.
Ultrasonic cleaning is extremely effective at removing dirt
an d gri me w h ic h wou ld no rma ll y re qu ire t edi ou s m an ual
clea nin g by hand .It has been use d to clea n a wide va rie ty
of ins trume nts and mec hanic a l parts such as carb uretor s,
returning them to almost “like new” condition without damage
to delicate parts.
Ultrasonic Cleaning Priciple
Detergent
ULTRASONIC PRINCIPLE
a: Lid
b: Control Panel
c:
: Housing
e: Power Cord
: Basket
d
Contents:
01 06
Press “ ” button,heater is turned on,the indicator light
blue,press “ ” button again to stop heating,indicator
07) the
turn the
light turn off.
08) When cleaning is completed,unplug the power cord,remove the
lid and retrieve th e items,Pour the wate r out through the
pouring recess.Clean and wipe the tank.
03 ) Cl ose t he l i d pl ug m ach in e i nt o pow er o utl et p res s th e , .
button to start machine“ ” .
When the water temperature reaches 60±3℃overheat protect indicator ,
light turn red the heater will turn off automatically.when the water,
temperature below 55±2℃heater will start to work automatically. ,
Adjust the timer according to the demand of
cleaning items.
VGT-6250
ab
f
f
Power Socket
e
d
c
06) Timer Setting.
Press the “ ” button to set timer,LED display shows “090”,
press it again to set it to “ ” the next each 180 . pressing make it
to increase by100 seconds.
05) Select “ ” to start degas mode Intermittent the , operation
ultrasonic power for rapid removal of of entrained air from liquids,
ultrasonic work 5 seconds and stop 2 seconds. the indicator
light turn green and flashing.Same cycle proceed.Press the
“ ” button again to stop it,indicator light(green) turn off.
04) Press “ ” button to start ultrasonic.the the indicator light
press “ ” again the ULTRASONIC turn green, to stop ultrasonic,
light turn off the indicator .