manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Häfele
  6. •
  7. Safe
  8. •
  9. Häfele CEU User manual

Häfele CEU User manual

Other Häfele Safe manuals

Häfele 836.21.351 Installation manual

Häfele

Häfele 836.21.351 Installation manual

Popular Safe manuals by other brands

Euromate 406210 Original instructions

Euromate

Euromate 406210 Original instructions

SPORTS AFIELD PRESERVE SA72-60WD instruction manual

SPORTS AFIELD

SPORTS AFIELD PRESERVE SA72-60WD instruction manual

Squire Stronghold Keysafe Fitting instructions

Squire

Squire Stronghold Keysafe Fitting instructions

Phoenix FS0352C Instructions & Guarantee Registration

Phoenix

Phoenix FS0352C Instructions & Guarantee Registration

Hornady SnapSafe Trunk Safe II owner's manual

Hornady

Hornady SnapSafe Trunk Safe II owner's manual

Phoenix KS0030E Series operating instructions

Phoenix

Phoenix KS0030E Series operating instructions

Vaultek 10 Series Quick setup

Vaultek

Vaultek 10 Series Quick setup

Arregui CLASS operating instructions

Arregui

Arregui CLASS operating instructions

Technomax Trony Series Instruction handbook

Technomax

Technomax Trony Series Instruction handbook

SPORTS AFIELD INSTINCT BIOMETRIC Series instruction manual

SPORTS AFIELD

SPORTS AFIELD INSTINCT BIOMETRIC Series instruction manual

SPORTS AFIELD SA-HD5-BIO instruction manual

SPORTS AFIELD

SPORTS AFIELD SA-HD5-BIO instruction manual

Olymp GOsafe 110 operating instructions

Olymp

Olymp GOsafe 110 operating instructions

Phoenix SS0100E Operating Instructions & Guarantee Registration

Phoenix

Phoenix SS0100E Operating Instructions & Guarantee Registration

Ankaro ANK EZ I quick start guide

Ankaro

Ankaro ANK EZ I quick start guide

Honeywell 2077D - 1.21 Cubic Foot Anti-Theft Safe user guide

Honeywell

Honeywell 2077D - 1.21 Cubic Foot Anti-Theft Safe user guide

Beaumont SMART KEYBOX user guide

Beaumont

Beaumont SMART KEYBOX user guide

Phoenix FS1270E Series operating instructions

Phoenix

Phoenix FS1270E Series operating instructions

Shure T-Wall Series Assembly instructions

Shure

Shure T-Wall Series Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OPERATION INSTRUCTIONS FOR CEU
1. Using CEU to open the safe
Needing 2 groups of codes for CEU to open the safe with below steps:
A. Turn the switch (left side of CEU) to “ I ” location, on display show GOOd;
B. Input the current master code(factory preset:1111), confirm by pressing “#”, on display show
“GOOd”;
C. Connect CEU to the safe by the USB connected line;
D. Input the current opening code(factory preset:2222) and confirm by pressing “#”. Then safe and
CEU show “OPEN” on display, the door is open.
E. Turn the switch (left side of CEU) to “O” to close CEU.
Note: Every CEU and safe will have a series number for connection, and the series number
of CEU must be same as that for safe.
2. Programming the master code & opening code
A. Programming the master code
a. Press “*” twice, on display show “PrOG”;
b. Input the current master code(factory preset :1111);
c. Press “*”, then input “1”, on display shows “NEU – C1”;
d. Input 4-digit new master code and confirm by pressing “#”, on display show “dONE”. The
new master code sets successfully.
B. Programming the opening code
a. Press “*” twice, on display show “PrOG”;
b. Input the current opening code(factory preset: 2222);
c. Press “*”, then input “2”, on display show “NEU – C2”;
d. Input 4-digit new opening code and confirm by pressing “#”, on display show dONE. The new
opening code sets successfully.
C. Resetting above codes to the factory preset code
a. Press “*” twice, on display show “PrOG”;
b. Input factory order code “6208”;
c. Press“*”, then input “9”, on display show “rESEt”;
That means the master code and opening code go back to the factory preset codes(master code
“1111” & opening code “2222”)
3. Viewing lock opening records from safe
A. Connect CEU with the safe well by the USB connected line;
B. Press “*” twice, on display show “PrOG”;
C. Input factory order code “5968”;
D. Press “*”, then input “8”, on display show “rEAD”. Now the records in the safe are being
transferred to CEU. At the same time, safe shows “SENd” count.
E. When both CEU and safe display show “dONE”, the records transfer finish.
4. Reading the record in the computer
A. Insert the attached disk and set the software into the computer;
B. Connect the CEU and computer with USB connected line, the screen of CEU will show “PC-LINKED”
during the connection.
C. If the CEU is closed, please turn on CEU at first.
D. Start the software, then check and print the opening records by computer.
Note: Please kindly make sure the CEU is not at OVERRIDE mode during the connection to the
computer. If It is failed to link to the computer, turn if off and then turn on again.
5. Setting the Date and Time in CEU
A. By button on CEU
a. Press “*” twice, on display shows “PrOG”;
b. Input factory order code “5968”;
c. Press “*”, then input “4”, on display show “YEAR, MONTH, DAY”(2 figures for each);
d. Input the new “YEAR, MONTH, DAY” ;
e. Press “#” into the second display. It shows “HOUR, MINUTE, SECOND”(two figures for each);
f. Input the new “HOUR, MINUTE, SECOND” and confirm by pressing “#”;
g. On display show “dONE”. The new date and time set successfully.
B. By computer
a. Connect the CEU with the computer and run the software for CEU.
b. Click the calibration of CEU time. After the computer show successful calibration, the CEU will
have same time as computer.
1/8 2/8
OPERATION INSTRUCTIONS FOR CEU
6. Transferring the information(locking setting/date/time) from CEU to
safety box
A. Press * twice, on display show “PrOG”;
B. Input factory order code “5968”;
C. Press *, then input “0”, on display show “DONE”, it means the locking setting/date/time in
CEU transfer well into the safety box.
7. SETTING THE CEU SERIAL CODE
The CEU and each safe have serial codes which can be programmed and set so that only
authorised CEU units can operate with an authorised number of safes. It is the decision of
the installation owner as to whether or not they choose to set this function.
Once set the CEU will only communicate with safes with the same serial number and so it
is necessary to programme all safes accordingly.
All CEU and Safes have the factory setting 0-0-0-0
a. To set the CEU Serial code
I. With the CEU turned on, press **, the display will show ”PrOG”
II. Input the factory reset code ”9207”
III. Press *and then press ”5” the display will show ”NEU-SO”
IV. Input the new 4 digit serial code followed by #” the display will show ”dONE” and the new
CEU Serial code is now set.
b. To set the Safe Serial code
I. Connect the CEU to the safe via the USB cable supllied and turn on the CEU by pressing
the side mounted swith to the ”I” position. The unit will beep and the display will show
”GOOd”
II. Keeping the CEU turned on, press **, the display will show ”PrOG”
III. Input the factory reset code ”9207”
IV. Press *and then press ”6” the display will show ”OLD-SO”
V. Input the old safe Serial code (factory set code is 0-0-0-0) followed by #, the display will
show ”dONE” followed by ”NEU-SO”
VI. Input the new 4 digit serial code (N.B. This must match the CEU Serial Code) followed
by #” the display will show ”dONE” and the new Safe Serial code is now set.
8. Setting of renting function
A. If you want to rent your safe to the customer, you should set the time for renting. When the
renting time is over, the safe will be locked, the user code will not open the safe door but the
master code of safe and the CEU can be used.
Please connect the communication interface of CEU with the safe, and must confirm it is well
connected.
1) Press button“*”twice. You will see “PROG” on the LED screen.
2) Input the factory number:8090
3) Press button “*” and “4”
4) Input correct year and month (with two digits), and press “#” to next screen.
5) Input the correct “day and hour” (2 figures for each), and press “#” for confirmation.
6) On display show “dONE”. The renting function is set successfully.
B. CLOSE THE RENTING FUNCTION
Please connect the communication interface of CEU with the safe, and must confirm it is well
connected.
1) Press button”*” twice, you will see “PrOG” on the LED screen.
2) Input the factory number: “8090”
3) Press “*” and “5”, you will see dONE on the screen.
4) The renting function is closed.
3/8 4/8
Error code
Reference
Error1
Wrong master code
Error2
Wrong opening code
Error3
Wrong selection
Error4
Series number of CEU doesn’t match that of safe
Error5
Overtime connection of CEU with safe
Error6
Failed message transmission between CEU and safe