H3C S1216 User manual

H3C S1216/1224 Ethernet Switch
User Manual
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: T2-UM-20080418-1.06

Copyright © 2005-2008, Hangzhou H3C Technologies Co.,
Ltd.
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form
or by any means without prior written consent of Hangzhou H3C
Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H3Care,
, TOP G, , IRF,
NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath,
Comware, Secware, Storware, NQA, VVG, V2G, VnG, PSPT, XGbus,
N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou
H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the
property of their respective owners.
CE
This equipment complies with the following European Directives:
89/336/EEC (electromagnetic compatibility), 73/23/EEC (low voltage).
Notice
The information in this document is subject to change without notice.
Every effort has been made in the preparation of this document to
ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of
any kind, express or implied.
To obtain the latest information, please access:
http://www.h3c.com

Technical Support
soho@h3c.com
http://www.h3c.com

About This Manual
Organization
This document is organized as follows:
Chapter Content
Chapter1 Product
Overview This chapter describes the appearance and
features of this product.
Chapter2 Switch
Installation This chapter describes the precautions and
steps to install this product.
Conventions
The manual uses the following conventions:
Symbols
I.
Convention Description
Caution
Means reader be careful. Improper
operation may cause data loss or damage
to equipment.
Note Means a complementary description.

Environmental Protection
This product has been designed to comply with the requirements on
environmental protection. For the proper storage, use and disposal of
this product, national laws and regulations must be observed.

User Manual
H3C S1216/1224 Ethernet Switch Table of Contents
i
Table of Contents
Chapter 1 Product Overview ........................................................1-1
1.1 Introduction ........................................................................1-1
1.2 Product Specifications .......................................................1-1
1.3 Hardware Description ........................................................1-3
1.3.1 Product Appearance................................................1-3
1.3.2 LEDs........................................................................1-5
Chapter 2 Switch Installation .......................................................2-1
2.1 Installation Preparations ....................................................2-1
2.1.1 Safety precautions...................................................2-1
2.1.2 Installation Environment..........................................2-2
2.1.3 Electromagnetic Environment .................................2-2
2.2 Installing the Switch...........................................................2-3
2.2.1 Sticking feet.............................................................2-3
2.2.2 Connecting Power Cord..........................................2-3
2.2.3 Examining the Installation .......................................2-4

User Manual
H3C S1216/1224 Ethernet Switch Chapter 1 Product Overview
1-1
Chapter 1 Product Overview
1.1 Introduction
H3C S1216 and S1224 Ethernet switches are management-free
Gigabit Ethernet products. They offer wire-speed Layer 2 switching
that is available immediately after the products are powered on
without any configuration.
The S1216 provides 16 autosensing 10/100/1000Base-T
Ethernet ports and the S1224 offers 24 autosensing
10/100/1000Base-T Ethernet ports.
1.2 Product Specifications
Table 1-1 Specifications of the S1216/1224
Item Description
Physical dimensions
(H × W × D)
S1216: 44 × 330 × 230 mm (1.7 × 13.0 ×
9.1 in.)
S1224: 44 × 330 × 230 mm (1.7 × 13.0 ×
9.1 in.)
Port
S1216: 16 autosensing
10/100/1000Base-T Ethernet ports
S1224: 24 autosensing
10/100/1000Base-T Ethernet ports

User Manual
H3C S1216/1224 Ethernet Switch Chapter 1 Product Overview
1-2
Item Description
Port attributes
RJ-45 connector
Compliant with IEEE 802.3, IEEE 802.3u
and IEEE 802.3ab
10/100/1000 Mbps transmission rates
Half duplex, full duplex and
auto-negotiation
Auto-MDI/MDI-X
Cable
10Base-T:
Category-3/-4/-5 twisted pair cable, with
maximum transmission distance 100 m
(328.1 ft.)
100Base-TX:
Category-5 twisted pair cable, with
maximum transmission distance 100 m
(328.1 ft.)
1000Base-T:
Category-5 twisted pair cable, with
maximum transmission distance 100 m
(328.1 ft.)
Input voltage 100 VAC to 240 VAC, 50 Hz/60 Hz
Power consumption S1216: 24 W
S1224: 30 W
Operating
temperature 0°C to 40°C (0°F to 107°F)
Storage temperature –10°C to +70°C (14°F to 158°F)
Operating humidity
(noncondensing) 20% to 85%
Storage humidity
(noncondensing) 10% to 90%

User Manual
H3C S1216/1224 Ethernet Switch Chapter 1 Product Overview
1-3
Item Description
System cooling One fan for cooling
Table 1-2 Features of the S1216/1224
Features Description
Wire-speed Layer 2
switching All ports support wire-speed forwarding
All ports are in the same broadcast domain
Switching mode Store and forward
MAC address Address auto-learning and auto-aging
(with aging time 300 seconds)
Maximum MAC address entries:
1.3 Hardware Description
1.3.1 Product Appearance
I. Front panel
As shown in Figure 1-1, the S1216 has on its front panel from the
left to the right: power LED, port LEDs, 16 10/100/1000Base-T ports
and one flow control switch.
Figure 1-1 Front view of the S1216

User Manual
H3C S1216/1224 Ethernet Switch Chapter 1 Product Overview
1-4
Note:
zYou can enable/disable the flow control function of the S1216 by
turning the flow control switch to “ON” and “OFF” respectively.
zIf any change is made to the flow control function status, reboot the
switch so that the change takes effect.
As shown in Figure 1-2, the S1224 has on its front panel from the
left to the right: power LED, port LEDs, 24 10/100/1000Base-T ports
and one flow control switch.
Figure 1-2 Front view of the S1224
Note:
zYou can enable/disable the flow control function of the S1224 by
turning the flow control switch to “ON” and “OFF” respectively.
zIf any change is made to the flow control function status, reboot the
switch so that the change takes effect.
II. Rear panel
The S1216/1224 has an AC power socket, a grounding pole, and
a vent on its rear panel as shown in Figure 1-3.

User Manual er 1 Product Overview
H3C S1216/1224 Ethernet Switch Chapt
1-5
Figure 1-3 Rear view of the S1216/1224
1.3.2 LEDs
Table 1-3 LEDs of the S1216/1224
LED Status Indication
ON The switch is powered on.
Power OFF The switch is powered off.
Green The port works in 1000 Mbps mode.
Orange The port works in 10/100 Mbps mode.
Speed
OFF No Ethernet link is present.
Green An Ethernet link is present.
Blinking green Packets are being received and/or
transmitted at the port.
Link/Act
OFF No Ethernet link is present.

User Manual
H3C S1216/1224 Ethernet Switch Chapter 2 Switch Installation
2-1
Chapter 2 Switch Installation
2.1 Installation Preparations
2.1.1 Safety precautions
To avoid any equipment damage or bodily injury caused by
improper use of the S1216/1224, take the precautions listed below:
zBefore cleaning the switch, unplug the switchconnector first.
Do not clean the switch with wet cloth or liquid.
zDo not place the switch near water or in any damp area.
Prevent water or moisture from entering the switch chassis.
zKeep the switch to operate in a clean environment. Heavy
dust will not only affect the life span of the device, but also
cause communication failure due to the static absorption in
the environment.
zThe S1216/1224 performs the cooling with a fan as it
generates a large amount of heat. Keep the switch in good
ventilation condition. Do not place one switch on another.
zThe switch can only operate normally under proper voltage
input. Make sure that the operating voltage is consistent with
that labeled on the switch.
zDo not open the chassis while the switch is in operation. Do
not open the chassis if not necessary, even when the switch
is not powered on.

User Manual
H3C S1216/1224 Ethernet Switch Chapter 2 Switch Installation
2-2
Caution:
There is a seal on one mounting screw on the chassis of the switch.
This seal must remain intact unless the agent is on the spot to
maintain your switch. Please contact your local agent and get
permission if you need to open the chassis. Otherwise, you will have
to bear the responsibilities for all the serious consequences arising
therefrom.
2.1.2 Installation Environment
The S1216/1224 can be installed in the corridor or inside the
room. The following requirements should be met for the installation:
zThere is enough space (more than 10 cm (0.33 in.)) near the
ventilation hole of the switch for heat dissipation of the
switch chassis.
zThe installation site has an effective cooling system.
zThe cabinet where the S1216/1224 is located is solid
enough to hold the S1216/1224 and its accessories.
zThe cabinet is well grounded.
2.1.3 Electromagnetic Environment
In operation, the switch may be affected by exterior interference
in radiation and conduction way. Therefore, be sure to:
zUse a monophase three-wire power socket with Protection
Earth (PE) as the AC power supply unit is a TN system.

User Manual
H3C S1216/1224 Ethernet Switch Chapter 2 Switch Installation
2-3
Thereby, the filter circuit in the equipment can effectively
filter interference from the power supply system.
zKeep the switch far away from high-power radio launchers,
radar launchers, and equipments with high-frequency and
high-current.
zUse electromagnetic shielding if necessary. For example,
use shielded port cable.
zWire the port cable indoors. Outdoor cabling is prohibited, to
prevent the signal port from possible damages that may be
caused by overvoltage and overcurrent of lightning strike.
2.2 Installing the Switch
Note:
During the installation, you are recommended to wear an
ESD-preventive wrist strip, which can be connected to the grounding
cable of the workbench, to eliminate possible static damage to the
switch.
2.2.1 Sticking feet
Step 1: Remove the paper covering the adhesive end of the feet.
Step 2: Stick the adhesive end of the feet to the circular recess on
the bottom of the chassis.
2.2.2 Connecting Power Cord
Step 1: Check if the required power supply unit is used.

User Manual
H3C S1216/1224 Ethernet Switch Chapter 2 Switch Installation
2-4
Step 2: Insert one end of the power cord to the input socket of the
switch and the other end to the socket of the external power supply.
Step 3: Check the status of the Power LED on the switch. ON
means the connection is OK.
2.2.3 Examining the Installation
zCheck if the cables are correctly connected with the
S1216/1224.
zCheck if all port cables are wired indoors.
This manual suits for next models
1
Table of contents
Other H3C Network Router manuals

H3C
H3C MSR 20 Series User manual

H3C
H3C RA10 Operating and maintenance manual

H3C
H3C s5800 series User manual

H3C
H3C SR6604 User manual

H3C
H3C AR 46-80 User manual

H3C
H3C S3100 Series User manual

H3C
H3C H3C S5600 Series User manual

H3C
H3C SR6600 SPE-FWM Installation manual

H3C
H3C CR16000-F User manual

H3C
H3C SR6600 SPE-FWM User manual

H3C
H3C MSR 900 Series User manual

H3C
H3C S12508CR Operating and maintenance manual

H3C
H3C S5150-EI Series User manual

H3C
H3C MSR Series Installation manual

H3C
H3C S1526 User manual

H3C
H3C CR16000-F Installation manual

H3C
H3C MSR5620 User manual

H3C
H3C S5500-EI series User manual

H3C
H3C MSR Series User manual

H3C