Electrical connectionFunction
In the system Tebis, the wind gauge TG050 is
used as a protection device for solar shading
equipment against strong wind. The speed of
the wind is measured
by the wind gauge.
If the wind’s speed exceeds the value adjusted
on the potentiometer for longer than three
seconds, the solar shading equipment is
retracted and kept in security position for
10 minutes.
After this delay, if the wind speed has
decreased, the solar shading equipment can
again be controlled by switches.
Technical Specifications
Product composition :
• Wind gauge with fixing set
• Connection enclosure IP 65
• Fixing screws for the casing (drilling ⌀6 mm)
Electrical data
• Supply voltage : 230 V 쓒50 Hz
• Contact loading capacity:
230 V 쓒4 A
(internal protection over fuse 4 A inertly)
Operation data
• Adjustment of wind’s speed limit :
up to 55 km/h (range ex-works 25 km/h)
• Reaction time when exceeding this limit:
3 seconds (5 seconds max.)
• Close time at wind : 10 minutes (fixed)
Environment
• Protection class II
• Protection degree IP 65
• Operating temperature:
from -25°C to +50°C
Connection
• Cage clamps : 0.5 ☐to 2.5 ☐
Dimensions
• The waterproof enclosure:
80 x 100 x 52 mm
• Fixing holes-distance : 90 mm.
Safety Recommendations :
- Must be connected by a qualified
technician in accordance with
the relevant electrical standards
and local restrictions.
- It is important to connect
the Ph - N in the right polarity.
no
polarity
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
12345678
Adjustment of wind’s speed
Towards the 230V
input of TXA304,
TXA306 or TXA310
278
Supply 230V쓒
BUS 30 V
Ph N
TG050
Input device
230V쓒
Solar
equipment
control
M
Limit
Instructions for watertight
mounting :
- fix the enclosure with outer
brackets
- Drill through the membrane
with a small sharp object
- Push and turn wire through
membrane
- Leave a curl to allow water
flowing
- Do not open other cable
entries that are not used.
Connection to the
distribution board
Elektrische aansluitingWerkingsprincipe
Als onderdeel van de systemen Tebis wordt de
windbeveiligingsdetector TG050 gebruikt ter
beveiliging van rolluiken tegen windstoten.
Wanneer de windsnelheid, die door de
anemometer gemeten wordt, gedurende
3 volle seconden een drempel die door de
potentiometer geregeld wordt, overschrijdt,
wordt het volledige optrekmechanisme van de
rolluiken geblokkeerd. De rolluiken blijven dan
gedurende minstens 10 minuten in de hoogste
stand (manuele impulsen worden genegeerd).
Wanneer de snelheid van de wind na
10 minuten voldoende is afgenomen, wordt
de windbeveiliging gedesactiveerd. Vanaf dan
kunnen de rolluiken opnieuw manueel bediend
worden.
Technische specificaties
Productsamenstelling :
• Een anemometer met een bevestigingssteun
• Een dichte koppelingsdoos
• Bevestigingsschroeven voor de doos
(boorgat ⌀6 mm)
Elektrische karakteristieken
• Voedingsspanning : 230 V 쓒50 Hz
• Contacttype (windbeveiliging :
230 V 쓒4 A (beveiligd met een vertraagde
zekering van 4 A)
Functionele karakteristieken
• Instelbare windsnelheidsdrempel :
tot 55 km/uur per potentiometer
standaardinstelling: 25 km/uur)
• Reactietijd na overschrijden van de drempel:
3 seconden (maximaal 5 seconden)
• Blokkeringtijd: 10 minuten (vast ingesteld)
Omgeving
• Isoleringsklasse II
• Veiligheidsindex IP 65 (in overeestemming
met de installatie-richtlijnen)
• werkingstemperatuur : van -25 °C tot +50 °C
Aansluiting
• capaciteit : 0,5 ☐tot 2,5 ☐
Afmeting
• Afmetingen van de dichte doos:
80 x 100 x 52 mm
• Bevestigingsafstand: 90 mm.
Aanbevelingen bij het installeren :
1. Om de Waterdichtheit van de installatie te
garanderen wordt aanbevolen het hierboven
weergegeven schema te volgen.
2. De Kabel van de anemometer moet overal op
minstens 1 cm afstand van de andere Kabels
gehouden worden.
3. de windsnelheidsdrempel moet via de
potentiometer geregeld worden in functie van
de weerstand van de rolluiken.
4. Let er op dat de anemometer niet gehinderd
wordt (muur, geplooide rolluik, ...).
geen
polariteit
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
12345678
Regeling
van de
windsnelheid
Naar ingang 230V
van TXA304,
TXA306 of TXA310
278
Voedingsspanning 230V쓒
BUS 30 V
Ph N
TG050
Ingangsmodule
230V쓒
Sturing
van de
rollluiken
M
drempel
Aanwijzingen voor een
waterdichte aansluiting :
- De doos moet aan de
buitenkant vastgezet worden
met montage-gehaken.
- Doorboor het midden van de
beschermwand door er een
kabel al draaiend doorheen
te steken.
- Als de wand beschadigd
wordt, kan men en pakkingbus
gebruiken om de water-
dichtheid te garanderen
- Een lus voorzlen voor de
afwatering
- De ongebruikte kabelingangen
niet doorboren. Verbinding
elektrisch bokd
Opgepast :
- De aansluiting moet gebeuren
door een erkend installateur
en volgens de geldende normen
en plaatselijke voorschriften in
verband met aansluitingen.
- Het is belangrijk de polarité Ph-N.
Wiring principle system Tebis
A warranty period of 24 months is offered on hager products,
from date of manufacture, relating to any material of
manufacturing defect. If any product is found to be defective it
must be returned via the installer and supplier (wholesaler). The
warranty is withdrawn if :
- after inspection by hager quality control dept the device is
found to have been installed in a manner which is contrary to
IEE wiring regulations and accepted practice within the
industry at the time of installation.
- the procedure for the return of goods has not been followed.
Explanation of defect must be included when returning goods.
Warranty
°
§
24 maanden tegen elk materiaal- of fabricagegebrek, en dit
vanaf de fabricagedatum.
In geval van defect, moet het produkt, aan uw verdeler
overhandigd worden.
De waarborg is enkel geldig indien de procedure van
terugzending installateur/verdeler nageleefd wordt en indien na
onderzoek door onze controledienst geen enkel gebrek
vastgesteld werd wegens het verkeerd in werking stellen en/of
het niet gebruiken volgens de regels van de kunst.
Eventuele opmerkingen betreffende het gebrek moeten het
produkt begeleiden.
Waarborg
°
•
Notices before taking into operation :
1. To guarantee the water proofness during
assembly, follow the instructions in the sketch
below.
2. Always keep a minimum distance of 1 cm
between the cable of the wind gauge and the
other cables.
3. Adjust the limit value of wind’s speed according
to shutter manufacturer instruction with the
potentiometer.
4. Assure that the wind gauge’s function isn’t
hindered (by wall, closed shades and so on).
Aansluitingsprincipe met het systeem Tébis

2 3 6T 6017.b6T 6017.b
6T 6017.b
TG050
Wind gauge
User instruction
¢
£
§
6T 6017.b
TG050
Windbeveiligingsdetector
Bedieningshandleiding
•
Electrical connectionFunction
In the system Tebis, the wind gauge TG050 is
used as a protection device for solar shading
equipment against strong wind. The speed of
the wind is measured
by the wind gauge.
If the wind’s speed exceeds the value adjusted
on the potentiometer for longer than three
seconds, the solar shading equipment is
retracted and kept in security position for
10 minutes.
After this delay, if the wind speed has
decreased, the solar shading equipment can
again be controlled by switches.
Technical Specifications
Product composition :
• Wind gauge with fixing set
• Connection enclosure IP 65
• Fixing screws for the casing (drilling ⌀6 mm)
Electrical data
• Supply voltage : 230 V 쓒50 Hz
• Contact loading capacity:
230 V 쓒4 A
(internal protection over fuse 4 A inertly)
Operation data
• Adjustment of wind’s speed limit :
up to 55 km/h (range ex-works 25 km/h)
• Reaction time when exceeding this limit:
3 seconds (5 seconds max.)
• Close time at wind : 10 minutes (fixed)
Environment
• Protection class II
• Protection degree IP 65
• Operating temperature:
from -25 °C to +50 °C
Connection
• Cage clamps : 0.5 ☐to 2.5 ☐
Dimensions
• The waterproof enclosure:
80 x 100 x 52 mm
• Fixing holes-distance : 90 mm.
Safety Recommendations :
- Must be connected by a qualified
technician in accordance with
the relevant electrical standards
and local restrictions.
- It is important to connect
the Ph - N in the right polarity.
no
polarity
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
12345678
Adjustment of wind’s speed
Towards the 230V
input of TXA304,
TXA306 or TXA310
278
Supply 230V쓒
BUS 30 V
Ph N
TG050
Input device
230V쓒
Solar
equipment
control
M
Limit
Instructions for watertight
mounting :
- fix the enclosure with outer
brackets
- Drill through the membrane
with a small sharp object
- Push and turn wire through
membrane
- Leave a curl to allow water
flowing
- Do not open other cable
entries that are not used.
Connection to the
distribution board
Elektrische aansluitingWerkingsprincipe
Als onderdeel van de systemen Tebis wordt de
windbeveiligingsdetector TG050 gebruikt ter
beveiliging van rolluiken tegen windstoten.
Wanneer de windsnelheid, die door de
anemometer gemeten wordt, gedurende
3 volle seconden een drempel die door de
potentiometer geregeld wordt, overschrijdt,
wordt het volledige optrekmechanisme van de
rolluiken geblokkeerd. De rolluiken blijven dan
gedurende minstens 10 minuten in de hoogste
stand (manuele impulsen worden genegeerd).
Wanneer de snelheid van de wind na
10 minuten voldoende is afgenomen, wordt
de windbeveiliging gedesactiveerd. Vanaf dan
kunnen de rolluiken opnieuw manueel bediend
worden.
Technische specificaties
Productsamenstelling :
• Een anemometer met een bevestigingssteun
• Een dichte koppelingsdoos
• Bevestigingsschroeven voor de doos
(boorgat ⌀6 mm)
Elektrische karakteristieken
• Voedingsspanning : 230 V 쓒50 Hz
• Contacttype (windbeveiliging :
230 V 쓒4 A (beveiligd met een vertraagde
zekering van 4 A)
Functionele karakteristieken
• Instelbare windsnelheidsdrempel :
tot 55 km/uur per potentiometer
standaardinstelling : 25 km/uur)
• Reactietijd na overschrijden van de drempel :
3 seconden (maximaal 5 seconden)
• Blokkeringtijd: 10 minuten (vast ingesteld)
Omgeving
• Isoleringsklasse II
• Veiligheidsindex IP 65 (in overeestemming
met de installatie-richtlijnen)
• werkingstemperatuur : van -25 °C tot +50 °C
Aansluiting
• capaciteit : 0,5 ☐tot 2,5 ☐
Afmeting
• Afmetingen van de dichte doos:
80 x 100 x 52 mm
• Bevestigingsafstand: 90 mm.
Aanbevelingen bij het installeren :
1. Om de Waterdichtheit van de installatie te
garanderen wordt aanbevolen het hierboven
weergegeven schema te volgen.
2. De Kabel van de anemometer moet overal op
minstens 1 cm afstand van de andere Kabels
gehouden worden.
3. de windsnelheidsdrempel moet via de
potentiometer geregeld worden in functie van
de weerstand van de rolluiken.
4. Let er op dat de anemometer niet gehinderd
wordt (muur, geplooide rolluik, ...).
geen
polariteit
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
12345678
Regeling
van de
windsnelheid
Naar ingang 230V
van TXA304,
TXA306 of TXA310
278
Voedingsspanning 230V쓒
BUS 30 V
Ph N
TG050
Ingangsmodule
230V쓒
Sturing
van de
rollluiken
M
drempel
Aanwijzingen voor een
waterdichte aansluiting :
- De doos moet aan de
buitenkant vastgezet worden
met montage-gehaken.
- Doorboor het midden van de
beschermwand door er een
kabel al draaiend doorheen
te steken.
- Als de wand beschadigd
wordt, kan men en pakkingbus
gebruiken om de water-
dichtheid te garanderen
- Een lus voorzlen voor de
afwatering
- De ongebruikte kabelingangen
niet doorboren. Verbinding
elektrisch bokd
Opgepast :
- De aansluiting moet gebeuren
door een erkend installateur
en volgens de geldende normen
en plaatselijke voorschriften in
verband met aansluitingen.
- Het is belangrijk de polarité Ph-N.
Wiring principle system Tebis
A warranty period of 24 months is offered on hager products,
from date of manufacture, relating to any material of
manufacturing defect. If any product is found to be defective it
must be returned via the installer and supplier (wholesaler). The
warranty is withdrawn if :
- after inspection by hager quality control dept the device is
found to have been installed in a manner which is contrary to
IEE wiring regulations and accepted practice within the
industry at the time of installation.
- the procedure for the return of goods has not been followed.
Explanation of defect must be included when returning goods.
Warranty
°
§
24 maanden tegen elk materiaal- of fabricagegebrek, en dit
vanaf de fabricagedatum.
In geval van defect, moet het produkt, aan uw verdeler
overhandigd worden.
De waarborg is enkel geldig indien de procedure van
terugzending installateur/verdeler nageleefd wordt en indien na
onderzoek door onze controledienst geen enkel gebrek
vastgesteld werd wegens het verkeerd in werking stellen en/of
het niet gebruiken volgens de regels van de kunst.
Eventuele opmerkingen betreffende het gebrek moeten het
produkt begeleiden.
Waarborg
°
•
Notices before taking into operation :
1. To guarantee the water proofness during
assembly, follow the instructions in the sketch
below.
2. Always keep a minimum distance of 1 cm
between the cable of the wind gauge and the
other cables.
3. Adjust the limit value of wind’s speed according
to shutter manufacturer instruction with the
potentiometer.
4. Assure that the wind gauge’s function isn’t
hindered (by wall, closed shades and so on).
Aansluitingsprincipe met het systeem Tébis

2 3 6T 6017.b6T 6017.b
6T 6017.b
TG050
Wind gauge
User instruction
¢
£
§
6T 6017.b
TG050
Windbeveiligingsdetector
Bedieningshandleiding
•
Electrical connectionFunction
In the system Tebis, the wind gauge TG050 is
used as a protection device for solar shading
equipment against strong wind. The speed of
the wind is measured
by the wind gauge.
If the wind’s speed exceeds the value adjusted
on the potentiometer for longer than three
seconds, the solar shading equipment is
retracted and kept in security position for
10 minutes.
After this delay, if the wind speed has
decreased, the solar shading equipment can
again be controlled by switches.
Technical Specifications
Product composition :
• Wind gauge with fixing set
• Connection enclosure IP 65
• Fixing screws for the casing (drilling ⌀6 mm)
Electrical data
• Supply voltage : 230 V 쓒50 Hz
• Contact loading capacity:
230 V 쓒4 A
(internal protection over fuse 4 A inertly)
Operation data
• Adjustment of wind’s speed limit :
up to 55 km/h (range ex-works 25 km/h)
• Reaction time when exceeding this limit:
3 seconds (5 seconds max.)
• Close time at wind : 10 minutes (fixed)
Environment
• Protection class II
• Protection degree IP 65
• Operating temperature:
from -25 °C to +50 °C
Connection
• Cage clamps : 0.5 ☐to 2.5 ☐
Dimensions
• The waterproof enclosure:
80 x 100 x 52 mm
• Fixing holes-distance : 90 mm.
Safety Recommendations :
- Must be connected by a qualified
technician in accordance with
the relevant electrical standards
and local restrictions.
- It is important to connect
the Ph - N in the right polarity.
no
polarity
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
12345678
Adjustment of wind’s speed
Towards the 230V
input of TXA304,
TXA306 or TXA310
278
Supply 230V쓒
BUS 30 V
Ph N
TG050
Input device
230V쓒
Solar
equipment
control
M
Limit
Instructions for watertight
mounting :
- fix the enclosure with outer
brackets
- Drill through the membrane
with a small sharp object
- Push and turn wire through
membrane
- Leave a curl to allow water
flowing
- Do not open other cable
entries that are not used.
Connection to the
distribution board
Elektrische aansluitingWerkingsprincipe
Als onderdeel van de systemen Tebis wordt de
windbeveiligingsdetector TG050 gebruikt ter
beveiliging van rolluiken tegen windstoten.
Wanneer de windsnelheid, die door de
anemometer gemeten wordt, gedurende
3 volle seconden een drempel die door de
potentiometer geregeld wordt, overschrijdt,
wordt het volledige optrekmechanisme van de
rolluiken geblokkeerd. De rolluiken blijven dan
gedurende minstens 10 minuten in de hoogste
stand (manuele impulsen worden genegeerd).
Wanneer de snelheid van de wind na
10 minuten voldoende is afgenomen, wordt
de windbeveiliging gedesactiveerd. Vanaf dan
kunnen de rolluiken opnieuw manueel bediend
worden.
Technische specificaties
Productsamenstelling :
• Een anemometer met een bevestigingssteun
• Een dichte koppelingsdoos
• Bevestigingsschroeven voor de doos
(boorgat ⌀6 mm)
Elektrische karakteristieken
• Voedingsspanning : 230 V 쓒50 Hz
• Contacttype (windbeveiliging :
230 V 쓒4 A (beveiligd met een vertraagde
zekering van 4 A)
Functionele karakteristieken
• Instelbare windsnelheidsdrempel :
tot 55 km/uur per potentiometer
standaardinstelling : 25 km/uur)
• Reactietijd na overschrijden van de drempel :
3 seconden (maximaal 5 seconden)
• Blokkeringtijd: 10 minuten (vast ingesteld)
Omgeving
• Isoleringsklasse II
• Veiligheidsindex IP 65 (in overeestemming
met de installatie-richtlijnen)
• werkingstemperatuur : van -25 °C tot +50 °C
Aansluiting
• capaciteit : 0,5 ☐tot 2,5 ☐
Afmeting
• Afmetingen van de dichte doos:
80 x 100 x 52 mm
• Bevestigingsafstand: 90 mm.
Aanbevelingen bij het installeren :
1. Om de Waterdichtheit van de installatie te
garanderen wordt aanbevolen het hierboven
weergegeven schema te volgen.
2. De Kabel van de anemometer moet overal op
minstens 1 cm afstand van de andere Kabels
gehouden worden.
3. de windsnelheidsdrempel moet via de
potentiometer geregeld worden in functie van
de weerstand van de rolluiken.
4. Let er op dat de anemometer niet gehinderd
wordt (muur, geplooide rolluik, ...).
geen
polariteit
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
12345678
Regeling
van de
windsnelheid
Naar ingang 230V
van TXA304,
TXA306 of TXA310
278
Voedingsspanning 230V쓒
BUS 30 V
Ph N
TG050
Ingangsmodule
230V쓒
Sturing
van de
rollluiken
M
drempel
Aanwijzingen voor een
waterdichte aansluiting :
- De doos moet aan de
buitenkant vastgezet worden
met montage-gehaken.
- Doorboor het midden van de
beschermwand door er een
kabel al draaiend doorheen
te steken.
- Als de wand beschadigd
wordt, kan men en pakkingbus
gebruiken om de water-
dichtheid te garanderen
- Een lus voorzlen voor de
afwatering
- De ongebruikte kabelingangen
niet doorboren. Verbinding
elektrisch bokd
Opgepast :
- De aansluiting moet gebeuren
door een erkend installateur
en volgens de geldende normen
en plaatselijke voorschriften in
verband met aansluitingen.
- Het is belangrijk de polarité Ph-N.
Wiring principle system Tebis
A warranty period of 24 months is offered on hager products,
from date of manufacture, relating to any material of
manufacturing defect. If any product is found to be defective it
must be returned via the installer and supplier (wholesaler). The
warranty is withdrawn if :
- after inspection by hager quality control dept the device is
found to have been installed in a manner which is contrary to
IEE wiring regulations and accepted practice within the
industry at the time of installation.
- the procedure for the return of goods has not been followed.
Explanation of defect must be included when returning goods.
Warranty
°
§
24 maanden tegen elk materiaal- of fabricagegebrek, en dit
vanaf de fabricagedatum.
In geval van defect, moet het produkt, aan uw verdeler
overhandigd worden.
De waarborg is enkel geldig indien de procedure van
terugzending installateur/verdeler nageleefd wordt en indien na
onderzoek door onze controledienst geen enkel gebrek
vastgesteld werd wegens het verkeerd in werking stellen en/of
het niet gebruiken volgens de regels van de kunst.
Eventuele opmerkingen betreffende het gebrek moeten het
produkt begeleiden.
Waarborg
°
•
Notices before taking into operation :
1. To guarantee the water proofness during
assembly, follow the instructions in the sketch
below.
2. Always keep a minimum distance of 1 cm
between the cable of the wind gauge and the
other cables.
3. Adjust the limit value of wind’s speed according
to shutter manufacturer instruction with the
potentiometer.
4. Assure that the wind gauge’s function isn’t
hindered (by wall, closed shades and so on).
Aansluitingsprincipe met het systeem Tébis

2 3 6T 6017.b6T 6017.b
6T 6017.b
TG050
Wind gauge
User instruction
¢
£
§
6T 6017.b
TG050
Windbeveiligingsdetector
Bedieningshandleiding
•
Electrical connectionFunction
In the system Tebis, the wind gauge TG050 is
used as a protection device for solar shading
equipment against strong wind. The speed of
the wind is measured
by the wind gauge.
If the wind’s speed exceeds the value adjusted
on the potentiometer for longer than three
seconds, the solar shading equipment is
retracted and kept in security position for
10 minutes.
After this delay, if the wind speed has
decreased, the solar shading equipment can
again be controlled by switches.
Technical Specifications
Product composition :
• Wind gauge with fixing set
• Connection enclosure IP 65
• Fixing screws for the casing (drilling ⌀6 mm)
Electrical data
• Supply voltage : 230 V 쓒50 Hz
• Contact loading capacity:
230 V 쓒4 A
(internal protection over fuse 4 A inertly)
Operation data
• Adjustment of wind’s speed limit:
up to 55 km/h (range ex-works 25 km/h)
• Reaction time when exceeding this limit:
3 seconds (5 seconds max.)
• Close time at wind : 10 minutes (fixed)
Environment
• Protection class II
• Protection degree IP 65
• Operating temperature:
from -25°C to +50 °C
Connection
• Cage clamps : 0.5 ☐to 2.5 ☐
Dimensions
• The waterproof enclosure:
80 x 100 x 52 mm
• Fixing holes-distance : 90 mm.
Safety Recommendations :
- Must be connected by a qualified
technician in accordance with
the relevant electrical standards
and local restrictions.
- It is important to connect
the Ph - N in the right polarity.
no
polarity
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
1234567 8
Adjustment of wind’s speed
Towards the 230V
input of TXA304,
TXA306 or TXA310
278
Supply 230V쓒
BUS 30 V
Ph N
TG050
Input device
230V쓒
Solar
equipment
control
M
Limit
Instructions for watertight
mounting :
- fix the enclosure with outer
brackets
- Drill through the membrane
with a small sharp object
- Push and turn wire through
membrane
- Leave a curl to allow water
flowing
- Do not open other cable
entries that are not used.
Connection to the
distribution board
Elektrische aansluitingWerkingsprincipe
Als onderdeel van de systemen Tebis wordt de
windbeveiligingsdetector TG050 gebruikt ter
beveiliging van rolluiken tegen windstoten.
Wanneer de windsnelheid, die door de
anemometer gemeten wordt, gedurende
3 volle seconden een drempel die door de
potentiometer geregeld wordt, overschrijdt,
wordt het volledige optrekmechanisme van de
rolluiken geblokkeerd. De rolluiken blijven dan
gedurende minstens 10 minuten in de hoogste
stand (manuele impulsen worden genegeerd).
Wanneer de snelheid van de wind na
10 minuten voldoende is afgenomen, wordt
de windbeveiliging gedesactiveerd. Vanaf dan
kunnen de rolluiken opnieuw manueel bediend
worden.
Technische specificaties
Productsamenstelling :
• Een anemometer met een bevestigingssteun
• Een dichte koppelingsdoos
• Bevestigingsschroeven voor de doos
(boorgat ⌀6 mm)
Elektrische karakteristieken
• Voedingsspanning : 230 V 쓒50 Hz
• Contacttype (windbeveiliging :
230 V 쓒4 A (beveiligd met een vertraagde
zekering van 4 A)
Functionele karakteristieken
• Instelbare windsnelheidsdrempel :
tot 55 km/uur per potentiometer
standaardinstelling: 25 km/uur)
• Reactietijd na overschrijden van de drempel:
3 seconden (maximaal 5 seconden)
• Blokkeringtijd: 10 minuten (vast ingesteld)
Omgeving
• Isoleringsklasse II
• Veiligheidsindex IP 65 (in overeestemming
met de installatie-richtlijnen)
• werkingstemperatuur : van -25 °C tot +50 °C
Aansluiting
• capaciteit : 0,5 ☐tot 2,5 ☐
Afmeting
• Afmetingen van de dichte doos:
80 x 100 x 52 mm
• Bevestigingsafstand: 90 mm.
Aanbevelingen bij het installeren :
1. Om de Waterdichtheit van de installatie te
garanderen wordt aanbevolen het hierboven
weergegeven schema te volgen.
2. De Kabel van de anemometer moet overal op
minstens 1 cm afstand van de andere Kabels
gehouden worden.
3. de windsnelheidsdrempel moet via de
potentiometer geregeld worden in functie van
de weerstand van de rolluiken.
4. Let er op dat de anemometer niet gehinderd
wordt (muur, geplooide rolluik, ...).
geen
polariteit
NL
230V쓒
F4A T 250V
5km/h
30km/h
55km/h
1234567 8
Regeling
van de
windsnelheid
Naar ingang 230V
van TXA304,
TXA306 of TXA310
278
Voedingsspanning 230V쓒
BUS 30 V
Ph N
TG050
Ingangsmodule
230V쓒
Sturing
van de
rollluiken
M
drempel
Aanwijzingen voor een
waterdichte aansluiting :
- De doos moet aan de
buitenkant vastgezet worden
met montage-gehaken.
- Doorboor het midden van de
beschermwand door er een
kabel al draaiend doorheen
te steken.
- Als de wand beschadigd
wordt, kan men en pakkingbus
gebruiken om de water-
dichtheid te garanderen
- Een lus voorzlen voor de
afwatering
- De ongebruikte kabelingangen
niet doorboren. Verbinding
elektrisch bokd
Opgepast :
- De aansluiting moet gebeuren
door een erkend installateur
en volgens de geldende normen
en plaatselijke voorschriften in
verband met aansluitingen.
- Het is belangrijk de polarité Ph-N.
Wiring principle system Tebis
A warranty period of 24 months is offered on hager products,
from date of manufacture, relating to any material of
manufacturing defect. If any product is found to be defective it
must be returned via the installer and supplier (wholesaler). The
warranty is withdrawn if :
- after inspection by hager quality control dept the device is
found to have been installed in a manner which is contrary to
IEE wiring regulations and accepted practice within the
industry at the time of installation.
- the procedure for the return of goods has not been followed.
Explanation of defect must be included when returning goods.
Warranty
°
§
24 maanden tegen elk materiaal- of fabricagegebrek, en dit
vanaf de fabricagedatum.
In geval van defect, moet het produkt, aan uw verdeler
overhandigd worden.
De waarborg is enkel geldig indien de procedure van
terugzending installateur/verdeler nageleefd wordt en indien na
onderzoek door onze controledienst geen enkel gebrek
vastgesteld werd wegens het verkeerd in werking stellen en/of
het niet gebruiken volgens de regels van de kunst.
Eventuele opmerkingen betreffende het gebrek moeten het
produkt begeleiden.
Waarborg
°
•
Notices before taking into operation :
1. To guarantee the water proofness during
assembly, follow the instructions in the sketch
below.
2. Always keep a minimum distance of 1 cm
between the cable of the wind gauge and the
other cables.
3. Adjust the limit value of wind’s speed according
to shutter manufacturer instruction with the
potentiometer.
4. Assure that the wind gauge’s function isn’t
hindered (by wall, closed shades and so on).
Aansluitingsprincipe met het systeem Tébis
Other manuals for TG050
1
Table of contents
Other hager Accessories manuals

hager
hager WXH21 Series User manual

hager
hager XEVS200 Operating and safety instructions

hager
hager 53600 User manual

hager
hager tre50 series User manual

hager
hager Muse User manual

hager
hager S761-22 User manual

hager
hager BODYGUARD-T Service manual

hager
hager 53622 User manual

hager
hager EEK51 P Series User manual

hager
hager BS Series User manual
Popular Accessories manuals by other brands

Eurotramp
Eurotramp Ground Trampoline Adventure Outdoor Use, Maintenance and Assembly Instructions

ring
ring BHAJB001 Installing and setting up

OBO Bettermann
OBO Bettermann UDHOME 2 G Mounting instructions

Topeak
Topeak PanoBike TPB-CS01 user guide

AOMAGO
AOMAGO V82 user manual

SELT
SELT AUSTRALIA installation manual