Hanna Instruments HI150-00 User manual

Instruction Manual
Manufactors since 1978
These Instruments are in
Compliance with the CE
Directives
HI 150 Series
Thermometers
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for correct
operation. Please read it carefully before using the meter. If
you need additional technical information, do not hesitate
to e-mail us at [email protected].
These instruments are in compliance with the directives EN
50081-1 and EN 50082-1.
Remove the instrument from the packing material
and examine it carefully. If any damage has oc-
curred during shipment, immediately notify your
Dealer or the nearest Hanna Customer Service Cen-
ter.
The meters are supplied with 12 VDC power adapter.
Note: Conserve all packing material until the in-
strument has been observed to function
correctly because any defective item must be
returned in its original packing.
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
GENERAL DESCRIPTIONGENERAL DESCRIPTION
GENERAL DESCRIPTIONGENERAL DESCRIPTION
GENERAL DESCRIPTION
HI 150 is an indicator with a relay Output and
built-in LED Alarm Signal for the monitoring of
temperature.
Constructed in a compact casing and with a molded
eye, HI 150 can be installed on the QC bench or
wherever necessary to control the ambient tem-
perature of food chain, from the storage room to
the point of delivery.
The housing has been completely sealed against
vapors and humidity.
The measurement range is from -20 to 60ºC with
an excellent ±0.5ºC accuracy. The stainless steel
encapsulated sensor is positioned right on the
outer body of this thermometer to provide a rapid
response.
In order to ensure that temperature control is
never interrupted, HI 150 runs permanently on a
12 VDC power supply. Temperature is constantly
displayed on a large LCD so that the operator can
check it at any time.
HI 150 also offers a unique alarm control. Any
value from 0 to 50.0ºC (HI 150-00) or -20 to
20ºC (HI 150-10) can be adjusted as the setpoint
through a trimmer located on the back of the
meter. Should the temperature vary from this user-
selectable setpoint, the red LED blinks and the
relay is activated to warn of an abnormality or
switch on a system. The built-in LED is well visible
from a distance.
This alarm relay is a cost-saving feature with a
tremendous potential that can help you in auto-
mating your temperature control. It can also be
used as a forewarning that the refrigeration or air
conditioning unit is malfunctioning, or that a door
has been left open, or point to any other mishaps,
common in a busy workplace.
HI 150 is a convenient and inexpensive way to
ensure that temperature never varies too much
from acceptable levels. It frees workers from hav-
ing to manually check the temperature and
immediately signals if and when an abnormality
arises.
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
HI150-00HI150-00
HI150-00HI150-00
HI150-00
Range -20.0 to 60.0ºC
Resolution 0.1ºC
Accuracy ±0.5ºC
Setpoint Selectable from 0.0 to 50.0 ºC
Hysteresis ±0.5ºC around setpoint
Alarm LED blinks and alarm relay activated
when measured temperature is
lower than the setpoint
Relay Through contacts inside the meter
Sensor Incorporated, encapsulated stainless
steel
Environment -20 to 60ºC; RH 100%
Power supply External 12 VDC (included)
Dimensions 86 x 94 x 33mm (3.4 x 3.7 x 1.3”)
Weight 150g (5.2oz.)
HI150-10HI150-10
HI150-10HI150-10
HI150-10
Range -20.0 to 60.0ºC
Resolution 0.1ºC
Accuracy ±0.5ºC
Setpoint Selectable from -20.0 to 20.0 ºC
Hysteresis ±0.5ºC around setpoint
Alarm LED blinks and alarm relay activated
when measured temperature is
higher than the setpoint
Relay Through contacts inside the meter
Sensor Incorporated, encapsulated stainless
steel
Environment -20 to 60ºC; RH 100%
Power supply External 12 VDC (included)
Dimensions 86 x 94 x 33 mm (3.4 x 3.7 x 1.3”)
Weight 150g (5.2oz.)
OPERATIONAL GUIDEOPERATIONAL GUIDE
OPERATIONAL GUIDEOPERATIONAL GUIDE
OPERATIONAL GUIDE
TAKING MEASUREMENTS
• Turn the meter on by connecting the 12 VDC
power adapter to the meter and to the mains.
• A value will appear on the LCD to indicate the
temperature. Wait for a few minutes for the
display to stabilize.
ADJUSTING THE SETPOINT
With the HI 150, you can select your own setpoint
and be alerted with a visual LED alarm when an
abnormal situation arises.
• Unscrew and remove the rear panel and gasket
seal to access the MEASURE/SET switch.
FUNCTIONAL DESCRIPTIONFUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTIONFUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTION
1. Molded eye
2. Alarm LED
3. Access for relay contacts
4. 12VDC power adapter
(included)
5. Power supply connector
6. Sensor
7. Liquid Cristal Display
CE DECLARATIONCE DECLARATION
CE DECLARATIONCE DECLARATION
CE DECLARATION
OF CONFORMITYOF CONFORMITY
OF CONFORMITYOF CONFORMITY
OF CONFORMITY
Recommendations for Users
Before using these products, make sure that they are entirely suitable
for the environment in which they are used.
Operation of these instruments in residential areas could cause unac-
ceptable interferences to radio and TV equipment.
The metal band at the end of the probe is sensitive to electrostatic dis-
charges. Avoid touching this metal band at all times.
During operation, ESD wrist straps should be worn to avoid possible dam-
age to the probe by electrostatic discharges.
Any variation introduced by the user to the supplied equipment may de-
grade the instrument’s EMC performance.
To avoid electrical shock, do not use these instruments when voltages at the
measurement surface exceed 24 VAC or 60 VDC.
Use plastic beakers to minimize any EMC interferences.
To avoid damages or burns, do not perform any measurement in micro-
wave ovens.
PRINTED IN CANADA ISTRHI150R2 09/2004
http://www.hannacan.com
Hanna Instruments reserves the right to modify the
design, construction and appearance of its products
without advance notice.
WARRANTYWARRANTY
WARRANTYWARRANTY
WARRANTY
HI 150-00/10 thermometer is warranted for one year
against defects in workmanship and materials when
used for their intended purpose and maintained ac-
cording to instructions. The sensor are warranted for a
period of one year also. This warranty is limited to
repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of pur-
chase, serial number and the nature of the failure. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If
the instrument is to be returned to Hanna Instruments, first obtain a
Returned Goods Authorization Number from the Customer Service de-
partment and then send it with shipment costs prepaid. When shipping
any instrument, make sure it is properly packaged for complete protec-
tion.
To validate your warranty, fill out and return the enclosed warranty card
within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna
Instruments Inc.
• Replace the rear panel and the gasket, ensuring
the unit is properly closed.
• Move the switch to the left (SET Mode).
• With a small
screwdriver adjust the setpoint trimmer to dis-
play the desired value in the 0 to 50 ºC or -20
to 20ºC range (based on the model).
• Make sure the switch is moved back to the right
(MEASURE Mode).
• To utilize the relay function open the casing as
explained for setpoint calibration.
After wiring close the casing properly. The relay
wires should pass through the access hole.
• Whenever the temperature reading reaches the
setpoint ( considering the hysteresis ), the alarm
LED blinks and relay is activated.
RELAY CONNECTIONRELAY CONNECTION
RELAY CONNECTIONRELAY CONNECTION
RELAY CONNECTION

This manual suits for next models

1

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 145-00 User manual

Hanna Instruments

Hanna Instruments HI 145-00 User manual

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments HI 98501-1 User manual

Hanna Instruments

Hanna Instruments HI 98501-1 User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Hanna Instruments HI 98701 User manual

Hanna Instruments

Hanna Instruments HI 98701 User manual

Hanna Instruments HI 151-00 User manual

Hanna Instruments

Hanna Instruments HI 151-00 User manual

Hanna Instruments HI 92840 User manual

Hanna Instruments

Hanna Instruments HI 92840 User manual

Hanna Instruments HI 99556 User manual

Hanna Instruments

Hanna Instruments HI 99556 User manual

Hanna Instruments Checktemp series User manual

Hanna Instruments

Hanna Instruments Checktemp series User manual

Hanna Instruments HI145-20 User manual

Hanna Instruments

Hanna Instruments HI145-20 User manual

Hanna Instruments HI 93530 User manual

Hanna Instruments

Hanna Instruments HI 93530 User manual

Hanna Instruments HI 146-99 User manual

Hanna Instruments

Hanna Instruments HI 146-99 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 98710 User manual

Hanna Instruments

Hanna Instruments HI 98710 User manual

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments HI 8752 User manual

Hanna Instruments

Hanna Instruments HI 8752 User manual

Hanna Instruments HI 98509-1 User manual

Hanna Instruments

Hanna Instruments HI 98509-1 User manual

Hanna Instruments HI 151-02 User manual

Hanna Instruments

Hanna Instruments HI 151-02 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 9271 User manual

Hanna Instruments

Hanna Instruments HI 9271 User manual

Hanna Instruments HI 148 Series User manual

Hanna Instruments

Hanna Instruments HI 148 Series User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Popular Thermometer manuals by other brands

Maverick OvenChek ST-01 Specification sheet

Maverick

Maverick OvenChek ST-01 Specification sheet

Radio Shack Indoor Humidity Gauge Thermometer manual 

Radio Shack

Radio Shack Indoor Humidity Gauge Thermometer manual 

Blocklychain TH-104 instruction manual

Blocklychain

Blocklychain TH-104 instruction manual

Motorola MBP70SN quick start guide

Motorola

Motorola MBP70SN quick start guide

Parr Instrument 6772 Operating instructions manual

Parr Instrument

Parr Instrument 6772 Operating instructions manual

TFA EasyFlash 31.1117 operating instructions

TFA

TFA EasyFlash 31.1117 operating instructions

Sealey Auto Service Line VS904.V2 instructions

Sealey

Sealey Auto Service Line VS904.V2 instructions

Be.Better RX502 instructions

Be.Better

Be.Better RX502 instructions

Maverick Industries HD-377 user manual

Maverick Industries

Maverick Industries HD-377 user manual

Wuxi Medical Instrument Mercury Free Thermometer CR.W00 manual

Wuxi Medical Instrument

Wuxi Medical Instrument Mercury Free Thermometer CR.W00 manual

THERM PRO TP393 quick start guide

THERM PRO

THERM PRO TP393 quick start guide

Mr Safe IRT-100 user manual

Mr Safe

Mr Safe IRT-100 user manual

RayTek Raynger Series 3i Plus operating instructions

RayTek

RayTek Raynger Series 3i Plus operating instructions

Eco4us EK-MT1 quick start guide

Eco4us

Eco4us EK-MT1 quick start guide

Wetekom 89 99 48 instruction manual

Wetekom

Wetekom 89 99 48 instruction manual

Spengler Temp'O Laser instruction manual

Spengler

Spengler Temp'O Laser instruction manual

FGM SH210P user manual

FGM

FGM SH210P user manual

Hagen EXO TERRA PT2472 manual

Hagen

Hagen EXO TERRA PT2472 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.