manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Thermometer
  8. •
  9. Hanna Instruments HI98517/HI98518 User manual

Hanna Instruments HI98517/HI98518 User manual

This manual suits for next models

2

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 955502 User manual

Hanna Instruments

Hanna Instruments HI 955502 User manual

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments HI 9041 User manual

Hanna Instruments

Hanna Instruments HI 9041 User manual

Hanna Instruments HI 8757 User manual

Hanna Instruments

Hanna Instruments HI 8757 User manual

Hanna Instruments HI 93530 User manual

Hanna Instruments

Hanna Instruments HI 93530 User manual

Hanna Instruments HI 955202 User manual

Hanna Instruments

Hanna Instruments HI 955202 User manual

Hanna Instruments HI 9041 User manual

Hanna Instruments

Hanna Instruments HI 9041 User manual

Hanna Instruments HI145-00 User manual

Hanna Instruments

Hanna Instruments HI145-00 User manual

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments HI 98121 User manual

Hanna Instruments

Hanna Instruments HI 98121 User manual

Hanna Instruments HI 98509-1 User manual

Hanna Instruments

Hanna Instruments HI 98509-1 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments HI935012 User manual

Hanna Instruments

Hanna Instruments HI935012 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI150-00 User manual

Hanna Instruments

Hanna Instruments HI150-00 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments HI 92804 User manual

Hanna Instruments

Hanna Instruments HI 92804 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 9057 User manual

Hanna Instruments

Hanna Instruments HI 9057 User manual

Hanna Instruments HI 99550-00 User manual

Hanna Instruments

Hanna Instruments HI 99550-00 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Key®HI98517/HI98518
Pocket-sized
K-type Thermocouple
Thermometer
Key®HI98517 / HI98518
Pocket-sized
K-type Thermocouple
Thermometer
www.hannainst.com
IST98517R4 07/05
SPECIFICATIONS
Range
Key®°C (HI98517) -40 to 550°C
Key®°F (HI98518) -40 to 999°F
Resolution
Key®°C (HI98517) 1°C
Key®°F (HI98518) 1°F
Accuracy (@20°C/68°F)
Key®°C (HI98517) ±2°C
Key®°F (HI98518) ±4°F
Typical EMC Deviation
Key®°C (HI98517) ±2°C
Key®°F (HI98518) ±4°F
Response Time
approx. 20 seconds in water
Environment0 to 50°C (32 to 122°F);
RH max 95%
Battery Type / Life
4x1.5V alkaline / approx. 700 hours
Dimensions
175x41x23 mm (6.2x1.4x0.8")
Weight 78 g (3.0 oz.)
Key® is a registered trademark of "Hanna
Instruments"
ACCESSORIES
HI 98517-11 K-thermocouple probe
for air/gas
HI 98517-12 K-thermocouple probe
for surfaces
HI 98517-13 K-thermocouple probe
with sharp tip for pen-
etration of semisolids
HI 98517-15 K-thermocouple probe
with round tip for liq-
uid/general purpose,
length 170 mm (6.7'')
HI 98517-30 K-thermocouple probe
with round tip for liq-
uid/general purpose,
length 320 mm (12.6'')
OPERATION
• Remove the pro-
tective cap and
screw the probe
to the meter.
• Turn the Key®on.
• Use the Key® in
the appropriate
application. An im-
mersion level of 4
cm (1½") is rec-
ommended for liq-
uids. Under no cir-
cumstances im-
merse above the
connector. Make
sure that the body
of the meter is not
exposed to high
temperatures
(above 50°C).
• Wait for the reading to stabilize and,
if necessary, change the probe to
match your application (see acces-
sories for a complete listing).
• When not in use, switch the Key®
off.
• Do not disconnect the probe unless
necessary.
BEPS & BATTERY REPLACEMENT
Key® is provided with BEPS (Battery
Error Preventing System) that prevents
any erroneous reading due to low bat-
tery level by switching the meter off.
To replace the batteries, slide off the
battery compartment cover and replace
all four 1.5V batteries, while paying
attention to their polarity.
Batteries should only be replaced in a
safe area and using the battery type
specified in this instruction manual.
Key®is in compliance with the CE
directives.
WARRANTY
This meter is guaranteed for one year
against defects in workmanship and
materials when used for their intended
purpose and maintained according to
instructions. Probe is guaranteed for
six months. This warranty is limited to
repair or replacement free of charge.
Damages due to accident, misuse, tam-
pering or lack of prescribed
maintenance are not covered. If ser-
vice is required, contact the dealer from
whom you purchased the instrument.
If under warranty, report the model
number, date of purchase, serial num-
ber and the nature of the failure. If the
repair is not covered by the warranty,
you will be notified of the charges
incurred. If the instrument is to be re-
turned to Hanna Instruments, first obtain
a Returned Goods Authorization Num-
ber from the Customer Service
department and then send it with ship-
ment costs prepaid. When shipping any
instrument, make sure it is properly
packaged for complete protection.