SPECIFICATIONS
Range
Key®°C (HI98517) -40 to 550°C
Key®°F (HI98518) -40 to 999°F
Resolution
Key®°C (HI98517) 1°C
Key®°F (HI98518) 1°F
Accuracy (@20°C/68°F)
Key®°C (HI98517) ±2°C
Key®°F (HI98518) ±4°F
Typical EMC Deviation
Key®°C (HI98517) ±2°C
Key®°F (HI98518) ±4°F
Response Time
approx. 20 seconds in water
Environment0 to 50°C (32 to 122°F);
RH max 95%
Battery Type / Life
4x1.5V alkaline / approx. 700 hours
Dimensions
175x41x23 mm (6.2x1.4x0.8")
Weight 78 g (3.0 oz.)
Key® is a registered trademark of "Hanna
Instruments"
ACCESSORIES
HI 98517-11 K-thermocouple probe
for air/gas
HI 98517-12 K-thermocouple probe
for surfaces
HI 98517-13 K-thermocouple probe
with sharp tip for pen-
etration of semisolids
HI 98517-15 K-thermocouple probe
with round tip for liq-
uid/general purpose,
length 170 mm (6.7'')
HI 98517-30 K-thermocouple probe
with round tip for liq-
uid/general purpose,
length 320 mm (12.6'')
OPERATION
• Remove the pro-
tective cap and
screw the probe
to the meter.
• Turn the Key®on.
• Use the Key® in
the appropriate
application. An im-
mersion level of 4
cm (1½") is rec-
ommended for liq-
uids. Under no cir-
cumstances im-
merse above the
connector. Make
sure that the body
of the meter is not
exposed to high
temperatures
(above 50°C).
• Wait for the reading to stabilize and,
if necessary, change the probe to
match your application (see acces-
sories for a complete listing).
• When not in use, switch the Key®
off.
• Do not disconnect the probe unless
necessary.
BEPS & BATTERY REPLACEMENT
Key® is provided with BEPS (Battery
Error Preventing System) that prevents
any erroneous reading due to low bat-
tery level by switching the meter off.
To replace the batteries, slide off the
battery compartment cover and replace
all four 1.5V batteries, while paying
attention to their polarity.
Batteries should only be replaced in a
safe area and using the battery type
specified in this instruction manual.
Key®is in compliance with the CE
directives.
WARRANTY
This meter is guaranteed for one year
against defects in workmanship and
materials when used for their intended
purpose and maintained according to
instructions. Probe is guaranteed for
six months. This warranty is limited to
repair or replacement free of charge.
Damages due to accident, misuse, tam-
pering or lack of prescribed
maintenance are not covered. If ser-
vice is required, contact the dealer from
whom you purchased the instrument.
If under warranty, report the model
number, date of purchase, serial num-
ber and the nature of the failure. If the
repair is not covered by the warranty,
you will be notified of the charges
incurred. If the instrument is to be re-
turned to Hanna Instruments, first obtain
a Returned Goods Authorization Num-
ber from the Customer Service
department and then send it with ship-
ment costs prepaid. When shipping any
instrument, make sure it is properly
packaged for complete protection.

This manual suits for next models

2

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 151-02 User manual

Hanna Instruments

Hanna Instruments HI 151-02 User manual

Hanna Instruments HI 98121 User manual

Hanna Instruments

Hanna Instruments HI 98121 User manual

Hanna Instruments HI 93551R User manual

Hanna Instruments

Hanna Instruments HI 93551R User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments HI 93531 User manual

Hanna Instruments

Hanna Instruments HI 93531 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments Checktemp series User manual

Hanna Instruments

Hanna Instruments Checktemp series User manual

Hanna Instruments Checktemp HI 98501 User manual

Hanna Instruments

Hanna Instruments Checktemp HI 98501 User manual

Hanna Instruments HI 145-00 User manual

Hanna Instruments

Hanna Instruments HI 145-00 User manual

Hanna Instruments HI 145-01 User manual

Hanna Instruments

Hanna Instruments HI 145-01 User manual

Hanna Instruments HI 955502 User manual

Hanna Instruments

Hanna Instruments HI 955502 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 98710 User manual

Hanna Instruments

Hanna Instruments HI 98710 User manual

Hanna Instruments Checktemp1 HI 98510 User manual

Hanna Instruments

Hanna Instruments Checktemp1 HI 98510 User manual

Hanna Instruments HI 8757 User manual

Hanna Instruments

Hanna Instruments HI 8757 User manual

Hanna Instruments HI 151-00 User manual

Hanna Instruments

Hanna Instruments HI 151-00 User manual

Hanna Instruments HI 147-00 User manual

Hanna Instruments

Hanna Instruments HI 147-00 User manual

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments HI 955501 User manual

Hanna Instruments

Hanna Instruments HI 955501 User manual

Hanna Instruments HI 8752 User manual

Hanna Instruments

Hanna Instruments HI 8752 User manual

Hanna Instruments HI 92840 User manual

Hanna Instruments

Hanna Instruments HI 92840 User manual

Hanna Instruments HI 9040 User manual

Hanna Instruments

Hanna Instruments HI 9040 User manual

Popular Thermometer manuals by other brands

QEO FIRT 1000 DataVision user manual

QEO

QEO FIRT 1000 DataVision user manual

Exergen TemporalScanner 2000C Instructions for use

Exergen

Exergen TemporalScanner 2000C Instructions for use

DRUCK & TEMPERATUR Leitenberger XP100 operating manual

DRUCK & TEMPERATUR Leitenberger

DRUCK & TEMPERATUR Leitenberger XP100 operating manual

HYGIPLAS F306 instruction manual

HYGIPLAS

HYGIPLAS F306 instruction manual

Eurotron Mini T+RH instruction manual

Eurotron

Eurotron Mini T+RH instruction manual

Control Company TRACEABLE instructions

Control Company

Control Company TRACEABLE instructions

Velleman DVM002 manual

Velleman

Velleman DVM002 manual

Omega HH501DK user manual

Omega

Omega HH501DK user manual

Oregon Scientific RMR682A user manual

Oregon Scientific

Oregon Scientific RMR682A user manual

Milwaukee C12 LTGE Original instructions

Milwaukee

Milwaukee C12 LTGE Original instructions

NU Temp NU-701 user guide

NU Temp

NU Temp NU-701 user guide

NSA HGTM-02 manual

NSA

NSA HGTM-02 manual

ECOWITT WH32 manual

ECOWITT

ECOWITT WH32 manual

tibelec EM907 instructions

tibelec

tibelec EM907 instructions

Heitronics KT15 II operating instructions

Heitronics

Heitronics KT15 II operating instructions

Philips SBCSC550 Instructions for use

Philips

Philips SBCSC550 Instructions for use

CHY 804R operating instructions

CHY

CHY 804R operating instructions

Westfalia Wetekom ST-8810 instruction manual

Westfalia

Westfalia Wetekom ST-8810 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.