manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Thermometer
  8. •
  9. Hanna Instruments Checktemp Dip HI98539 User manual

Hanna Instruments Checktemp Dip HI98539 User manual

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 98501-1 User manual

Hanna Instruments

Hanna Instruments HI 98501-1 User manual

Hanna Instruments Checktemp2 User manual

Hanna Instruments

Hanna Instruments Checktemp2 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 98710 User manual

Hanna Instruments

Hanna Instruments HI 98710 User manual

Hanna Instruments HI 92840 User manual

Hanna Instruments

Hanna Instruments HI 92840 User manual

Hanna Instruments HI 98701 User manual

Hanna Instruments

Hanna Instruments HI 98701 User manual

Hanna Instruments HI 9063 User manual

Hanna Instruments

Hanna Instruments HI 9063 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments HI 9041 User manual

Hanna Instruments

Hanna Instruments HI 9041 User manual

Hanna Instruments HI 93551 User manual

Hanna Instruments

Hanna Instruments HI 93551 User manual

Hanna Instruments HI 9061 User manual

Hanna Instruments

Hanna Instruments HI 9061 User manual

Hanna Instruments Checktemp-Dir HI 98510-01 User manual

Hanna Instruments

Hanna Instruments Checktemp-Dir HI 98510-01 User manual

Hanna Instruments Checktemp1 HI 98510 User manual

Hanna Instruments

Hanna Instruments Checktemp1 HI 98510 User manual

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments HI 146-99 User manual

Hanna Instruments

Hanna Instruments HI 146-99 User manual

Hanna Instruments HI 93531 User manual

Hanna Instruments

Hanna Instruments HI 93531 User manual

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments Checktemp series User manual

Hanna Instruments

Hanna Instruments Checktemp series User manual

Hanna Instruments HI150-00 User manual

Hanna Instruments

Hanna Instruments HI150-00 User manual

Hanna Instruments HI 955502 User manual

Hanna Instruments

Hanna Instruments HI 955502 User manual

Hanna Instruments HI 9271 User manual

Hanna Instruments

Hanna Instruments HI 9271 User manual

Hanna Instruments HI 98509-1 User manual

Hanna Instruments

Hanna Instruments HI 98509-1 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

HI98539
Digital Thermometer
INSTRUCTION MANUAL
Checktemp®Dip
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent
of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA.
IST98539
11/15
Warranty
Checktemp®Dip is guaranteed for a period of one year after date of purchase against defects in workmanship and materials
when used for their intended purpose and maintained according to instructions. This warranty is limited to repair or
replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If
service is required, contact your local Hanna Office. If under warranty, report the model number, date of purchase, serial number
and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Technical
Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly
packed for complete protection.
Recommendations for Users
Before using Hanna Products, make sure that they are entirely suitable for your specific application and for the environment
in which they are used. Operation of these instruments may cause unacceptable interferences to other electronic equipment,
thus requiring the operator to take all necessary steps to correct such interferences. Batteries should only be replaced in a safe
area using the battery type specified in this instruction manual. Any variation introduced by the user to the supplied equipment
may degrade the instrument’s EMC performance. To avoid damages or burns, do not put the instrument in microwave oven. For
yours and the instrument safety do not use or store the instrument in hazardous environments.
Liquid Crystal Display
Silicone Probe Cable
ON/OFF
Button
SET
Button
Battery
Cover
REAR
°C °F
Range -20.0 to 80.0°C -4.0 to 176.0°F
Resolution 0.1°C 0.1°F
Accuracy ±0.3°C ±0.5°F
Probe weighted stainless steel probe with 3 m (9.9’) silicone cable
Battery Type / Life 3 x 1.5V AAA alkaline / approximately 2 years of use
Auto Off 8 min (default), 60 min or OFF
Environment -30 to 50°C (-22 to 122°F); IP65
Dimensions 107 x 59 x 17 mm (4.2 x 2.3 x 0.7’’)
Weight 109 g (3.8 oz.)
Operation
Turn Checktemp®Dip ON: all LCD segments are displayed for 1 second. CAL Check®
starts automatically to verify that Checktemp®Dip is still accurate to its
specications. A message of “CAL“ and “-0-“ means that Checktemp®Dip is within
specications. You can now start using Checktemp®Dip. If CAL Check® displays the
“Err” message while measuring temperature, remember that:
·The temperature sensor is located at the tip of the stainless steel probe.
·It is necessary to wait for a few seconds for the display to stabilize.
Specifications
Meter Setup
Enter Setup to change between Temperature Unit and to adjust the Auto Shut-o
time. To enter the Setup MODE, press the SET button located inside the battery
compartment once for Temperature Unit or twice for Auto Shut-o.
To enter the Setup mode, remove battery cover and press SET button. The display
will show the current temperature unit (E.g. “°C“). Then:
·Use the ON/OFF button to switch between “ºC” or “ºF”. Press SET once to save.
·Use the ON/OFF button to cycle through the following Auto Shut-off options:
8 minutes (“d08”, default value), 60 minutes (“d60”), OFF (“d--”). Press the SET
button once to save.
Battery Replacement
Replace the battery when the battery symbol is blinking or when Checktemp®Dip
does not turn on. Open the compartment and replace the three AAA batteries, while
paying attention to their polarity. Close battery cover.
Note: Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.
Old batteries should be disposed in accordance with local regulations.
Weighted
Temperature Probe
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna and our products, visit www.hannainst.com.
For technical support, contact your local Hanna oce or email us at tech@hannainst.com
Find your local Hanna oce on www.hannainst.com