5. WARNING: THE LCD SCREEN CABLE CONNECTOR IS VERY FRAGILE. When viewing the
underside of the MSP Local Terminal, you'll see the MSP circuit board which is held in place
by 4 Phillips head screws. Before removing the screws, the LCD screen ribbon cable must be
disconnected from the circuit board. The connector that holds the ribbon cable is very fragile
and care must be taken when attempting to unlock the latch.
Refer to the diagrams above and below and have a clear understanding of how the latch
works before attempting to unlock. There are two "wings", one on each side of the latch, that
must be released. Because the wings are connected to each other, lifting on one will release
both. With your fingernail, gently lift up on one of the wings. If you can't get your fingernail
under the wing, use the included plastic washer tool (two are included). Gently hook the tool
under a wing and lift up. If you still have trouble, use both tools, and lift both wings at the
same time. NOTE: Do not use any metal or rigid tool on the wings as the latch is fragile and
can easily break. Once the latch is released, gently pull the ribbon cable straight out from the
connector.
4 Phillips Head screws
LCD Screen
Cable Connector
Ribbon Cable
Ribbon Cable
Latch "Wing"
Carefully use fingernail or included plastic washer tool to lift the connector
latch by the wings.
Connector Latch
(wings on each side)
Wing Wing
3
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS