HID Vertx CS V100 User manual

Quick Installation Guide
V100 DOOR/READER INTERFACE
PROPRIETARY INFORMATION. This document contains proprietary information which may not be duplicated,
published or disclosed to others, or used for any purpose without written permission from HID Corporation. 2004
© HID Corporation. All rights reserved.
Document Version 1.1
August 4, 2005
Document Number 6080-907B
9292 Jeronimo Road
Irvine, CA 92618-1905

VertX V100 (CS) Quick Installation Guide
August 2005 Page 2 of 9
2005 © HID Corporation. All rights reserved.
Contents
QUICK START, VERTX (CS) V100 Door/Reader Interface Panel.............................................1
Introduction.................................................................................................................................3
Parts List (included) ..........................................................................................................3
Product Specifications.......................................................................................................3
Cable Specifications..........................................................................................................3
Overview......................................................................................................................................4
Step 1 Preparations ....................................................................................................................4
1.1 What you need before getting started ...................................................................4
1.2 V100 ......................................................................................................................4
Step 2 Hardware Installation......................................................................................................5
2.1 Mounting Instructions ............................................................................................5
2.2 Wiring VertX ..........................................................................................................5
Contact Information....................................................................................................................8

VertX V100 (CS) Quick Installation Guide
August 2005 Page 3 of 9
2005 © HID Corporation. All rights reserved.
Introduction
VertX™ CS is the first family of access controllers designed specifically for alarm dealers for direct
connection to central stations. Because it was designed with central station in mind, VertX CS works with
software from leading central station automation providers, including Bold Technologies, DICE and
GE MAS.
The V100 is designed to be controlled by a VertX V1000 Access Controller that will also manage
communications with the central station automated software. The V100 Door/Reader Interface panel
controls two sets of door devices or one door with Card In/Card Out (a reader on both sides of the same
door.)
Parts List (included)
Parts List (included) Quantity
VertX™ V100 Door/Reader Interface
Note: The V100 panel has a plastic base
and is covered with a Plastic or Mylar cover.
1
Mounting screws 4
2.2K EOL resistors 4
Quick Installation Guide 1
Installation Wiring Diagram Example 1
Note: A VertX V1000 Access Controller is required.
Product Specifications
Description Specification
Power Supply 12-16VDC
Maximum current at 12VDC per V100 1 Amp
Average operating current at 12VDC 450mA (with two R40 iCLASS Readers)
Operating temperature range 32°-122°F (0°-50°C)
Humidity 5% to 95% non-condensing
Cable Specifications
Cable Type Length Specification
RS-485 * 4000 feet (1220 m) to V1000 Belden 3105A, 22AWG twisted pair, shielded 100Ωcable, or equivalent.
Input Circuits * 500 feet (150 m) 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C
(18AWG), or equivalent.
Output Circuits * 500 feet (150 m) 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG), or
equivalent.
Wiegand 500 feet (150 m) to reader ALPHA 1299C, 22AWG, 9-conductor, stranded, overall shield.
Fewer conductors needed if all control lines are not used.
Power Supply
+12 VDC IN ---- Refer to your Power Supply Installation Guide.
* Minimum wire gauge depends on cable length and current requirements.

VertX V100 (CS) Quick Installation Guide
August 2005 Page 4 of 9
2005 © HID Corporation. All rights reserved.
Terminating
Jumper
Overview
The following outlines what is required to install the V100 Door/Reader Interface panel.
Step 1 Preparations
1.1 What you need before getting started
Prior to starting the installation, please completely read through this guide.
CAUTION: The V100 is sensitive to Electrostatic Discharges (ESD). Observe precautions while
handling the circuit board assembly by using proper grounding straps and handling precautions at
all times.
1.2 V100
1. If the V100 will be attached to the end of the RS-485 bus, install a
terminating jumper on the termination resistor pins P8 on the cover
(P10 on the PCB) of the V100.
2. If the V100 is being installed as part of an array, or in a third party
enclosure, follow the directions provided by the Integrator or Dealer.

VertX V100 (CS) Quick Installation Guide
August 2005 Page 5 of 9
2005 © HID Corporation. All rights reserved.
Pin # P7
1 +12VDC
2 Ground
3 Bat Fail -
4 Bat Fail +
5 AC Fail -
6 AC Fail +
7 Tamper -
8 Tamper +
Pin # V100 P1 V100 P4
1 Reader Power Shield Ground
2 Ground Hold
3 Data 0 / Data Beeper
4 Data 1 / Clock Red LED
5 Data Return Green LED
6 Green LED Data Return
7 Red LED Data 1 / Clock
8 Beeper Data 0 / Data
9 Hold Ground
10 Shield Ground Reader Power
Step 2 Hardware Installation
2.1 Mounting Instructions
1. The V100 should always be mounted in a secure area.
2. Mount the V100 using the four mounting screws (provided) or other appropriate fasteners. Place the
fasteners in the corner holes of the base.
3. The V100 panel can be stacked with or without the cover. Do not remove the plastic base. Make sure
to position the V100 panel in such a way as to provide room for wiring, air-flow and cable runs.
2.2 Wiring VertX
1. Power and Alarm input connections: Connect power by providing 12VDC to the P7 connector.
+12VDC goes to Pin 1 and Ground on Pin 2. The Bat Fail, AC Fail, and Tamper switch inputs are
wired as shown in the table. Connect the Bat Fail and AC Fail inputs to battery low/failure and AC
failure contacts provided on the power supply. Connect the Tamper input to a tamper switch on the
enclosure.
2. Reader Connections: Connect Wiegand or
clock-and-data interfaces to the V100 using
the connection table shown. You can
connect up to 10 signal lines for the reader.
Use as many of the signal lines as required
for your reader interface.
Note: Connect the data return line to the
same ground as the reader power if the
reader is not powered by the VertX units
12VDC.
CAUTION: Connectors on the V100 sides are positioned to be mirror images and are not
interchangeable once the installation is complete. Therefore, you cannot unplug the connector from
one side of the board and plug it into the corresponding connector on the other side.

VertX V100 (CS) Quick Installation Guide
August 2005 Page 6 of 9
2005 © HID Corporation. All rights reserved.
3. RS-485 Connections: Connect the V100 to the V1000 through the RS-485 cable. See the V1000
Quick Install Guide for further information.
CAUTION: The V1000 RS-485 Ports 1 & 2 (P1) are a common bus and therefore cannot have
duplicate Interface Addresses assigned. The same is true of the V1000 RS-485, Ports 3 & 4 (P4).
For example, Interface Address 0 (factory default) cannot be assigned to both Ports 1 & 2 (P1).
4. Interface Address – Set the interface address by turning the Address dial. Ensure that
the V100 Interface Address is documented in the Hardware Installation Worksheet (found
in the back of the HID VertX V1000 Quick Install guide).
5. Output Connections – All Output connections are used for general
purpose controls. The following table shows where the various outputs are
located. Pin numbers shown use the convention “NO/C/NC”.
For example, Output 1, V2000: P3 Pin1 is NO (Normally open) and Pin 2 is
C (Common) and Pin 3 is NC (Normally closed).
Note: Relay contacts are rated for 2Amps @ 30VDC.
Output
number V2000 V1000 V100 V200 V300
1
P3 Pins 1/2/3
Strike (lock)
Relay 1
P14 Pins
2/3/4
P3 Pins 1/2/3
Strike (lock)
Relay 1
P3 Pins 2/3/4 P1 Pins 1/2/3
2 P3 Pins 4/5/6
Aux Relay 1
P11 Pins
6/5/4
P3 Pins 4/5/6
Aux Relay 1 P6 Pins 3/2/1 P1 Pins 4/5/6
3
P6 Pins 6/5/4
Strike (lock)
Relay 2
P6 Pins 6/5/4
Strike (lock)
Relay 2
P1 Pins 7/8/9
4 P6 Pins 3/2/1
Aux Relay 2 P6 Pins 3/2/1
Aux Relay 2 P2 Pins 1/2/3

VertX V100 (CS) Quick Installation Guide
August 2005 Page 7 of 9
2005 © HID Corporation. All rights reserved.
Output
number V2000 V1000 V100 V200 V300
5 P2 Pins 4/5/6
6 P2 Pins 7/8/9
7 P4 Pins 9/8/7
8 P4 Pins 6/5/4
9 P4 Pins 3/2/1
10 P5 Pins 9/8/7
11 P5 Pins 6/5/4
12 P5 Pins 3/2/1
6. Input Connections – Input connections are used for a combination of specific functions such as
Request-to-Exit (REX), Door monitor, etc. They can also be used for general purpose monitoring.
Connect one side of the switch or contact to the + (plus) lead and the other to the – (minus) lead. The
following table shows where the inputs are located. Pin numbers shown on the cover use the
convention +/–.
The default REX switch configuration is normally open (NO) unsupervised (no EOL resistors), while the
default door switch (DS) configuration is Normally Closed (NC) unsupervised (no EOL resistors). All
other input points are defaulted for NO switches and are unsupervised (no EOL resistors).
Any input can be configured as a supervised input. They can be configured for resistor values of 1K –
6K Ohm. The setup of supervised inputs should be done during configuration of the VertX units via the
central station automation software (host) or using the Calibrate Input tool explained in the HID VertX
V1000 Quick Installation guide.
Example: Input 1, V1000 is: P14 Pin1 is + and Pin 2 is -.
Input
Number V2000 V1000 V100 V200 V300
1 P2 Pins 1/2
Door Monitor P14 Pins 1/2 P2 Pins 1/2
Door Monitor P1 Pins 1/2 P6 Pins 2/1
2 P2 Pins 3/4
REX Input P11 Pins 4/3 P2 Pins 3/4
REX Input P1 Pins 3/4 P3 Pins 1/2
3 P5 Pins 4/3
Door Monitor
P7 Pins 8/7
Tamper
P5 Pins 4/3
Door Monitor P1 Pins 5/6 P7 Pins 8/7
Tamper
4 P5 Pins 2/1
REX Input
P7 Pins 6/5
AC Fail
P5 Pins 2/1
REX Input P1 Pins 7/8 P7 Pins 6/5
AC Fail
Supervised inputs can be configured for:
The default input will be all:

VertX V100 (CS) Quick Installation Guide
August 2005 Page 8 of 9
2005 © HID Corporation. All rights reserved.
Input
Number V2000 V1000 V100 V200 V300
5 P7 Pins 8/7
Tamper
P7 Pins 4/3
Batt Fail
P7 Pins 8/7
Tamper
P1 Pins 9/10 P7 Pins 4/3
Batt Fail
6 P7 Pins 6/5
AC Fail P7 Pins 6/5
AC Fail
P2 Pins 1/2
7 P7 Pins 4/3
Batt Fail P7 Pins 4/3
Batt Fail
P2 Pins 3/4
8 P2 Pins 5/6
9 P4 Pins 10/9
10 P4 Pins 8/7
11 P4 Pins 6/5
12 P4 Pins 4/3
13 P4 Pins 2/1
14 P5 Pins 6/5
15 P5 Pins 4/3
16 P5 Pins 2/1
17
P7 Pins 8/7
Tamper
18
P7 Pins 6/5
AC Fail
19
P7 Pins 4/3
Batt Fail
Contact Information
HID Corporation 929274 Jeronimo Road, Irvine, CA 92618-1905
Web Site http://www.hidcorp.com
Main Phone (949) 598-1600
Fax (949) 598-1698
Sales (800) 210-4744
Technical Support (800) 237-7769

VertX V100 (CS) Quick Installation Guide
August 2005 Page 9 of 9
2005 © HID Corporation. All rights reserved.
All National and local Electrical codes apply.
•This equipment is intended to be powered from a limited power source output of a
previously certified power supply.
•Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Class A Digital Devices
FCC Compliance Statement: This equipment has been tested and found to comply with the limits for a
Class. A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
Class B Digital Devices
FCC Compliance Statement: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an ex
p
erienced radio/TV technician for hel
p
.
Table of contents
Other HID Controllers manuals

HID
HID iCLASS SE RB25F User manual

HID
HID Mercury LP1501 User manual

HID
HID Signo 25B User manual

HID
HID Signo 25B User manual

HID
HID VertX EVO Series User manual

HID
HID EDGE EVO EH400 User manual

HID
HID Mercury LP4502 User manual

HID
HID ACW2-XN User manual

HID
HID Mercury LP1502 User manual

HID
HID VertX EVO V1000 User manual
Popular Controllers manuals by other brands

Universal Remote Control
Universal Remote Control total control MRX-10 owner's manual

Sinclair
Sinclair KJR-18B User and installation manual

WITA
WITA W05 installation manual

CAME
CAME ZL56 Original-spare parts

Vestamatic
Vestamatic MC P4 LoVo Installation and operating instructions

InDeM automation
InDeM automation VIVO 424 Installation and user manual