EN50131-2-4:2008
EN50131-1:2006+A1:2009
Security Grade (SG)2
Environmental Class(EC)IV
DS-PD2-T12P-WEL
12m Wireless Outdoor Detector
Diagram References
ENGLISH
Baery Informaon
1
2
3
4
5
6
7
8
Installation
Ensure that t he detector is installed away from reflected sunlight and large
objects.
Switches
If you disable the detector’s LEDs, you can remotely enable them in walk tests.
Microwave range and angle of detection
Use the highlighted dials to change the microwave range and angle
of detecon.
LEDs
Four LEDs show the status of the detector.
Lens inserts
Use lens inserts to control the coverage area.
Registration procedure
Aer powering up and aer registraon,there is a 10 minute mer that allows
a walk test of the PIR and microwave sensors.You can set up the sensivity and
microwave range without using the control panel to perform a walk test.Aer
10 minutes,the detector enters sleep mode. Please register the device within
90 seconds aer it being powered on.
Register Locally
1.Make the security control panel enter the registraon mode.
2. Register the detector: Hold the registraon key unl the three LEDs flash
alternately. The green LED will flash 8 mes if the registraon is finished.
3. Communicaon Test: Release the TEMPER spring to trigger the alarm.
Note: The distance between the security control panel and the detector should
be less than 50 cm.
Initialize the Detector
1. Remove the baery to power the detector off.
2. 5s later, hold the registraon key and reinstall the baery to power the
detector on at the same me to make the three LEDs start flashing alternately.
Release the registraon key while the three LEDs flash once together.
Signal strength test
Enter the signal checking mode by operang on the control panel
Indicator turns green:Strong Signal.
Indicator turns red:Weak Signal.
Bracket tamper signal input
The baeries supplied with this product have been chosen to provide long service life whilst, for safety
reasons, having limited output current.The baery leads must be connected for operaon. When disposing
of the product, remove the baeries and disposed of separately in accordance with the local regulaons.
Detectors Technical Characteriscs
Detecon Range
Detecon Angle
Detecon Zones
Detecon Speed
Mounng Height
Two-way Wireless Technology
Blue Wave Technology
Dual Element Pyroelectric Sensor
Tamper Protecon
Intergrated Walk Test Buzzer
Separated LED Indicaon:
Orange(Microwave),Blue(Alarm),Green(PIR)
Signal Strength Indicators (SSI)
3 Microwave Frequencies to Avoid Interference
Digital Independent Floang Threshold(IFT) Technology
Plasc Housing
Animal Immunity
Opcs
Adjustable Sensivity
Lens
Detecon Method
Sensor
Weatherproof
Cerfied Operang Temperature
Physical Dimensions(H x W x D)
Weight
Baery Type
Baery Life
Baery Capacity
Rotatable Wall Mounted
Fixed Wall Mounted
Ceiling Mounted
Baery
12m
90°
2x22 zones
0.25–2.5 m/s
1-1.5 m
Yes
Yes
Yes
Front, rear, and bracket tamper signal input
Yes
Top: Microwave, PIR 1 and alarm
Boom: PIR 2
Yes
Yes
Yes
3mm polycarbonate
Up to 24kg
Dual-vision sealed opcs
High or low range
UV compensated
Tri-Signal Detecon Logic
2 low noise dual element passive infrared sensors and a microwave doppler unit
IP55 rated
-25℃to +60℃(Cerfied)
118mm x 77mm x 84mm
0.3kg
2x3V 4700mAh Lithium baery packs
Up to 3 years
4700mAh
Yes – addional wall and fixed brackets available separately
Yes – addional wall and fixed brackets available separately
Yes – addional wall and fixed brackets available separately
Yes – addional baery available separately
Electrical & baery
Environmental and Operang Features
Accessories
Technical Specification
Battery Information
1
2
45
3
ON posion
LEDs on
Buzzer on
Top PIR high sensivity
Boom PIR high sensivity
1
2
3
4
OFF posion
LEDs off
Buzzer off
Top PIR low sensivity
Boom PIR low sensivity