HOMCOM 821-020V80 Installation guide


1
1. BEFORE YOU BEGIN
Please read the operating instructions carefully before using your dehumidifier for
the first time.
1.1 PRODUCT DESCRIPTION
The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in
relative humidity protects buildings and their contents from the adverse effects of excess
humidity.
2. FOR YOUR SAFETY
Your safety is the most important thing we concerned!
Please read this manual carefully and fully understand before operating your
dehumidifier.
2.1 OPERATIONALPRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons or property:
⚫If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
⚫The appliance shall be disconnected from its power source during maintenance.
⚫Always operate the unit from a power source of equal voltage, frequency and rating as
indicated on the product identification plate.
⚫Always use a power outlet that is grounded.
⚫Unplug the power cord when cleaning or when not in use.
⚫Do not operate with wet hands. Prevent water from spilling onto the unit.
⚫Do not immerse or expose the unit to rain, moisture or any other liquid.
⚫Do not leave the unit running unattended. Do not tilt or turn over the unit.
⚫Do not unplug while the unit is operating.

2
⚫Do not unplug by pulling on the power cord.
⚫Do not use an extension cord or an adapter plug.
⚫Do not put objects on the unit.
⚫Do not climb or sit on the unit.
⚫Do not insert fingers or other objects into the air outlet.
⚫Do not touch the air inlet or the aluminum fins of the unit.
⚫Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
⚫Do not clean the appliance with any chemicals.
⚫Ensure the unit is far away from fire, inflammable, or explosive objects.
⚫The unit shall be installed in accordance with national wiring regulations.
⚫Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture.
⚫The appliance shall be stored in a room without continuously operation sources (for example:
open flames, an operating gas appliance or an operating electric heater).
⚫The appliance shall be stored so as to prevent mechanical damage from occurring.
⚫Do not piece or burn, even after use.
⚫Be aware that refrigerants may not contain an odour.
⚫Pipe-work shall be protected from physical damage and shall not be installed in an
unventilated space, if that space is smaller than 4m².
⚫Compliance with national gas regulations shall be observed.
⚫Keep any required ventilation openings clear of obstruction.
⚫The appliance shall be stored in a well-ventilated area where the room size corresponds to the
room area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit should
hold a current valid certificate from an industry-accredited assessment authority, which authorizes
their competence to handle refrigerants safely in accordance with an industry, recognized
assessment specification.

3
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out
under the supervision of the person competent in the use of flammable refrigerants.
If you don't understand something or need help, please contact the dealer services
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing a dehumidifier with
R290.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system,
the following precautions shall be complied with prior to conducting work on the system.
2.2.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable
gas or vapor being present while the work is being performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be instructed on the nature of
work being carried out. Work in confined spaces shall be avoided. The area around the workspace
shall be sectioned off. Ensure that the conditions within the area have been made safe by control
of flammable material.
2.2.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to
ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak
detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking,
adequately sealed or intrinsically safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts,
appropriate fire extinguishing equipment shall be available to hand. Have a dry powder orCO2 fire
extinguisher adjacent to the charging area.
2.2.6 No ignition sources

4
No person carrying out work in relation to a refrigeration system which involves exposing any pipe
work that contains or has contained flammable refrigerant shall use any sources of ignition in
such a manner that it may lead to the risk of fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the site of installation,
repairing, removing and disposal, during which flammable refrigerant can possibly be released to
the surrounding space. Prior to work taking place, the area around the equipment is to be
surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs
shall be displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the
system or conducting any hot work. A degree of ventilation shall continue during the period that
the work is carried out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the
correct specification. At all times the manufacturer’s maintenance and service guidelines shall be
followed. If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
–The charge size is in accordance with the room size within which the refrigerant containing parts
are installed;
–The ventilation machinery and outlets are operating adequately and are not obstructed;
–If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the
presence of refrigerant;
–Marking to the equipment continues to be visible and legible. Markings and signs that are
illegible shall be corrected;
–refrigeration pipe or components are installed in a position where they are unlikely to be
exposed to any substance which may corrode refrigerant containing components, unless the
components are constructed of materials which are inherently resistant to being corroded or are
suitably protected against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and
component inspection procedures. If a fault exists that could compromise safety, then no

5
3 Color Digital Display
Front shell
electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue operation, an adequate
temporary solution shall be used. This shall be reported to the owner of the equipment so all
parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to avoid possibility of
sparking;
-that there no live electrical components and wiring are exposed while charging, recovering or
purging the system;
-that there is continuity of earth bonding
3. PRODUCT OVERVIEW
Control Panel
Air Outlet
Castors

6
3.2 FEATURES
✓Powerful moisture removal
✓Humidity Monitor shows current air humidity
✓Auto mode automatically adjusts humidity levels
✓A 24-hour timer to set the time of operation
✓Effectively removes moisture, dust from the air
✓Low power consumption-energy efficient
✓Quiet fan has two speed settings
✓Auto-Defrost at low temperature
✓Auto shut-off/ auto restart
✓Electronic control
✓Laundry drying function
✓Antibacterial Filter
✓Continuous drainage or 6.5L water tank
4. INSTALLATION
4.1 LOCATION
1.Place the unit on a firm, level surface in an area with at least 30cm of free space around it to allow for
Handle
Air Filter
Back Shell
Top panel
Water tank
Continuous drainage
口

7
proper air circulation.
2.Never install the unit where it could be subject to :
⚫Quellen Heat sources such as radiators, heating registers, stoves or other products that generate
heat.
⚫In an area where oil or water can be splashed
⚫SonnenlichtDirect sunlight
⚫Mechanical vibration or shock
⚫Excessive dust
⚫Poor ventilation, e.g. B. closet or bookcase
⚫Uneven surface
4.2 Operation the device safety
⚫Check the device after unpacking for any damages or scratches on it.
⚫Operate this unit in an ambient temperature from 5°C to 38°C.
⚫Do not use in the outdoors. This dehumidifier is intended for indoor residential applications
only.
⚫Do not operate in close proximity to walls, curtains, or other objects that may block inlet and
outlet.
⚫Keep the air inlet and outlet free of obstacles.
⚫Adjusting the wind deflector in the upward direction prior to start up.
⚫If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
⚫Keep doors and windows close for better energy saving.
⚫Do not operate or store the unit in direct sunlight or rain.

8
⚫It is normal for air outlet to feel warm to touch after continuous operation on hot days.
⚫Empty the water tank before moving the device.
⚫Make sure the Water tank is correctly fitted otherwise the unit will not operate properly.
⚫The dehumidifier starts up in the mode selected when the unit was last used.
⚫The dehumidifier starts dehumidifying if the room humidity is 3% higher than the selected
humidity.
⚫There is a protective 3-minutes time delay of the compressor. Wait 3 minutes for the
dehumidifier to resume dehumidification.
5.
OPERATION
5.1 DIGITAL DISPLAY
Ambient humidity < 40%, it shows blue
40% ≥ ambient humidity ≤ 60%, it turns green
ambient humidity >60%, it displays red
5.2 CONTROL PANEL
5.3 SETTINGS
Power
In the standby state, press the power button to turn on, the operation indicator lights up and the
default fan speed is high, the LED shows ambient humidity. In the power-on state, press the
power button to turn off, the running indicator light goes off and the compressor stops

9
immediately, and then the fan shut down after 30 seconds delay.
Mode
Auto mode - continuously drying mode-sleeping mode cycle, press once to switch the mode from
one to another, the corresponding indicator lights up.
● Auto mode: when environmental humidity ≥ set humidity +3%, the fan starts working and
compressor starts working after 3 seconds. When environmental humidity ≤ set humidity -3%,
the compressor stops working and fan stops working after 30 seconds’ delay.
Both fan speed and humidity can be adjusted under auto mode.
● Continuously drying mode: The machine continues to run, but the humidity can not be
adjusted.
●Sleeping mode: Touch the sleep button, the button lights up and start the sleep function.
Long Press and hold the sleep button 3S to reset the filter
Timer
Press the timer button to set the 0-12 hour timing function. The interval is 1 hour. Each time you
press this button, the value increased 1 hours and then the corresponding timing value is
displayed on the screen. The setting value is “00” to cancel the timer function. The indicator turns
out. After the timer is set and completed, the timer LED is on during the timing period. After the
timing is over, the timer LED turns off automatically.
In the running state, set the time to turn off the machine;
in the standby state, set the time to turn on the machine.
Note: when press POWER will also exit the timer setting.
Speed
Only in automatic mode, touch this button to switch between high and low fan speed, and the
indicator light is on
Up
Press this button to set up humidity and timing time;
Humidity adjusting the order of 30% to 35% - 40% - 45% - 50% - 55% - 60% - 65% - 70% -
75% - 80% - 30%;
Time set to 00, press this key, display 00 and blink, then press this key again every time, from
01-02-03-...... Minus 24 goes all the way up to +1
Down
Press this button to lower humidity setting and timing time;

10
Humidity adjusting the order of 30% to 80% - 75% - 70% - 65% - 60% - 55% - 50% - 45% -
40% - 35% - 30%;
Time set to 00, press this key, display 00 and blink, and then press this key again every time, from
24-23-22-...... The value of -00 keeps repeating -1
Child-lock(Lock)
When the machine is turned on, press the button for 3 seconds to open/close the child lock
function. When the button is turned on, the indicator light of the child lock is on. The indicator
light of child lock is off; After the child lock function is opened, the child lock function will be
cancelled automatically as long as the shutdown or power failure occurs
5.4 DRAINAGE
There are two ways of removal collected water produced by the unit.
A. Manual draining: Empty water tank by manual.
B. Continuous draining: Use gravity to drain condensate water by attaching a drain hose.
5.3.1 EMPTYING THE WATER TANK
The water tank built in unit will fill up and shut the unit down once it is full. It will run again once you empty the
water tank and installed properly.
1) When the tank is full, The unit will make a buzzing sound, and the “Water Full” light will turn on.
2) Press the POWER button to turn off the unit.
3) Pull on the water tank and simply slide out of the body of the dehumidifier.
4) Empty the water into an area with a drain or outside.
5) Clean the inside of the tank as well as the outside.
6) Replace the empty tank back into the unit.
7) Press the POWER button to resume operating.
8) If the Water Full light does not extinguish, check that the float is correctly in place.

11
1、Pull out the water tank
2、Empty the water tank
3、Replace the empty tank back into the
unit
III.Warning!
1、Do not discard the magnets and plastic rivets in
the tank. Otherwise, the dehumidifier cannot be
started, or the machine will not automatically stop
working when the water tank is full, and the
condensed water overflow will damage the floor of
the room.
2、Please make sure to clean the condensed water in the tank and put the tank in the original position
3、If the water tank is dirty, please rinse it with clean water. Avoid using detergents, steel wire balls,
chemical dust removers, diesel, benzene, diluents or other solvents. Otherwise, it can damage the tank

12
MAINTENANCE
Note: before cleaning and maintaining the machine, please be sure to turn off the machine
and unplug the power to avoid electric shock.
CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the
and cause leaks
4、Put the water tank in its original position. Otherwise, the indicator light will always be red and the
machine cannot start working again
Continuous drainage:
1、Take out the PVC pipe, Straighten the drain pipe
2、Insert one end of the drain pipe into the drain outlet at the top of the tank and connect the other end
to the bathroom, floor drain, outdoor or bucket like container, defined drain area
Warning
1、Please do not block the drain or drain pipe, if blocking phenomenon, condensed
water will flow into the tank
2、Please do not bend the drain pipe. The height of the drain pipe should be lower than
the outlet
3、The drain pipe must be firmly connected to the outlet
Drain pipe

13
efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not
operate the unit without an air filter, or the evaporator may be contaminated.
Switch off the unit and remove air filter;
Rinse under a running water or using the vacuum to
clean the dust
Reassemble the air filter

14
TROUBLESHOOTING
SYMPTOM
INSPECTION
SOLUTION
The unit is not
operating.
✓Check the power
connection in securely.
➢Insert the power cord securely into the
wall Outlet.
✓Check if the water level
indicator lights up?
➢Empty the water tank and reinstall correctly.
✓Check the room
temperature.
➢The range of operating temperature is
5-38℃.
There is little
formation of
condensate.
✓Check the air filter for dirt.
➢Clean the air filter as necessary.
✓Check if the air duct is
blocked.
➢To clear the obstacle.
✓Check if the room
temperature is below 20℃.
➢This is normal. Low humidity in low
temperature environment.
✓Set humidity level is higher
than current Humidity
value.
➢Set the humidity level below current humidity
value.
Water Leakage
✓Overflow while moving the
unit.
➢Empty the water tank before transport.
✓Check if the drain hose is
kinked or bends.
➢Straighten the hose to avoid a trap existing.
Excessive Noise
✓Check if the unit is securely
positioned.
➢Place the unit on horizontal and firm ground.
✓Check if any loose, vibrating
parts.
➢Secure and tight the parts.
✓Noise sounds like water
flowing.
➢Noise comes from flowing refrigerant. This is
normal.
Error
code
E2
✓Humidity sensor dampened
or failure.
➢To clean or replace the humidity sensor.
CL
✓Display when Room
temperature is below 5°C
(41°F).
➢Normal. The compressor stops, and the fan
keeps running.
CH
✓Display when Room
temperature is above38℃
(100°F).
➢Normal. The compressor stops, and the fan
keeps running.
LO
✓Display when Room relative
humidity is bellow 20%RH.
➢Normal. The compressor stops, and the fan
keeps running.
HI
✓Display when Room relative
humidity is above 90%RH.
➢Normal. The compressor and the fan keep
running.
Table of contents
Other HOMCOM Dehumidifier manuals

HOMCOM
HOMCOM 821-018V70 Installation guide

HOMCOM
HOMCOM 821-030V70 User manual

HOMCOM
HOMCOM 821-029V90 User manual

HOMCOM
HOMCOM 821-028V70 User manual

HOMCOM
HOMCOM 821-017V70 Installation guide

HOMCOM
HOMCOM 821-022V70 User manual

HOMCOM
HOMCOM 821-010V70 User manual

HOMCOM
HOMCOM 821-012 User manual

HOMCOM
HOMCOM 821-017V90 User manual

HOMCOM
HOMCOM 821-031V90 User manual