HoMedics TO-R100-0GB User manual

Probe Tip
On/Off Button
Temperature
Celsius/Fahrenheit
Low-battery
Memory Symbol
Battery Compartment (on back of unit)
DIGITAL THERMOMETER - Model TO-R100-0GB
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this HoMedics Digital Thermometer. Please read these instructions carefully to ensure
proper and safe operation.
IMPORTANT PRODUCT NOTICES AND SAFETY INSTRUCTIONS
• Please note that this product is intended for household use only and should not serve as a substitute for the advice
of a GP or medical professional. Do not use this device for diagnosis or treatment of any health problem or disease.
Measurement results are for reference only. Contact your GP if you have or suspect any medical problem.
• Prolonged high fever requires medical attention - especially for young children.
• This thermometer should only be used under the supervision of an adult.
• Toavoid injury,do not allow children to walk or run during temperature measurement.
WHAT IS NORMAL BODY TEMPERATURE? WHAT IS FEVER?
Normal body temperature is a range that varies from person to person, by age, and throughout the day. The average
normal body temperature is 37°C (98.6°F). Generally, an oral temperature ranging between 36.1°C (97°F) and 37.8°C
(100°F) is considered normal. A rectal temperature is generally 0.5°C (1°F) higher and an underarm (axillary) temperature
will be 0.5°C (1°F) lower.
Fever is defined as a body temperature elevated over an individual's normal body temperature. It is important to
determine each person's normal body temperature in order to properly assess whether or not a fever is actually present.
This can easily be determined by tracking temperatures on a consistent basis, measuring at the same site on the body
and at the same time each day.
WHATIS THE FEVER ALARM?
The Fever Alarm is a unique feature that will alert the user anytime a temperature reading is 37.8°C(100°F) or greater
with an audio alert of 30 short beeps. For readings at or above this temperature, it is LIKELY that a fever is present.
NOTE:Atemperature reading below 37.8°C (100°F) does not mean that a fever is not present. Likewise, a
temperature greater than or equal to 37.8°C (100°F) does not guarantee the presence of a fever.
BEFORE USE
It is recommended that the user avoid eating or drinking, smoking, exercising, or taking showers/baths for 20 minutes
prior to measurement.
PROBE COVERS
Disposable probe covers are recommended for use with this Digital Thermometer. To avoid contamination, place a
probe cover on the probe tip each time the thermometer will be used. Use only HoMedics probe covers for this
Digital Thermometer.Additional probe covers can be purchased from your retailer or by contacting HoMedics
OPERATING YOUR DIGITAL THERMOMETER
Press the ON/OFF button to activate the thermometer. The unit will beep and all display symbols will appear for
about 2 seconds. The thermometer will then display the last temperature reading taken for 1 second. The display
will next show 37°C (or 98.6°F) for about 1 second while the unit performs a self-test. The °C (or °F) symbol then will
begin flashing, indicating that the thermometer is ready for use.
During measurement, the display will show the highest temperature measured during the reading. To begin a
temperature reading, the thermometer should already be in the mouth, underarm or rectum when the ON/OFF button
is pressed. Otherwise, the display will show “Lo” until it is placed into the measurement site.
ORAL USE
1. It is suggested that the user sit quietly for 5 minutes with their mouth closed prior to taking a reading.
2. Cover the thermometer probe with a probe cover.
3. Place the probe under the tongue. Position the sensor tip in one of the areas
marked with a star in FIGURE 1. It is important to keep the mouth closed
during measurement to ensure an accurate reading. Be cautious not
to bite the thermometer.
4. When the peak temperature is reached, the thermometer will alert with
10 long beeps. The temperature measurement is ready to read and will not
change when removed from the mouth.
5. If the temperature is greater than or equal to 37.8°C (100°F), the fever alarm
will alert with a total of 30 short beeps.
6. Turn the thermometer off by pressing the ON/OFF button. If you forget to turn
the thermometer off, it will automatically shut-off after approximately 10 minutes of non-operation.
7. Dispose of the used probe cover and clean the thermometer as recommended.
★★
★
FIGURE 1.

UNDERARM (AXILLARY) USE
1. It is suggested that the user sit quietly with their arm at their side for 5 minutes prior to measurement.
2. Wipe the underarm with a dry towel.
3. Cover the thermometer probe with a probe cover.
4. Place the probe tip under the arm so the tip
is touching the skin (FIGURE 2).
5. Lower the arm so that it is positioned next to the body (FIGURE 3).
6. When the peak temperature is reached the thermometer will alert with
10 long beeps. The temperature measurement is ready to read and will
not change when removed from under the arm.
NOTE: Under the arm temperatures are generally 0.5°C (1°F) lower
than a temperature taken orally.
7. If the temperature is greater than or equal to 37.8°C (100°F), the fever alarm will alert with a total of 30 short beeps.
8. Turn the thermometer off by pressing the ON/OFF button. If you forget to turn the thermometer off, it will
automatically shut-off after approximately 10 minutes of non-operation.
9. Dispose of the used probe cover and clean the thermometer as recommended.
RECTAL USE
1. Cover the thermometer probe with a probe cover and lubricate with a water-soluble personal lubricant for easier insertion.
Do not use a petroleum jelly. Read the label of the lubricant you are using to ensure that it is the appropriate kind.
2. Lay the patient on their side. When using on an infant, carefully lay the baby on its stomach with legs hanging
down, either at the edge of a bed or changing table or across your knees. This will position the infant's rectum for
safe and easy insertion.
3. Gently insert the tip of the probe NO MORE THAN 12mm (1/2inch) into the rectum. Stop immediately if you detect
resistance. Hold the thermometer in place during measurement.
4. When the peak temperature is reached, the thermometer will alert with 10 long beeps. The temperature
measurement is ready to read and will not change when removed from the rectum.
NOTE: Rectal temperatures are generally 0.5°C (1°F) higher than a temperature taken orally.
5. If the temperature is greater than or equal to 37.8°C (100°F), the fever alarm will alert with a total of 30 short beeps.
6. Turn the thermometer off by pressing the ON/OFF button. If you forget to turn the thermometer off, it will
automatically shut-off after approximately 10 minutes of non-operation.
7. Dispose of the used probe cover and clean the thermometer as recommended.
TO RECALL THE LAST TEMPERATURE
When the thermometer is activated, the last temperature reading will automatically be displayed on the LCD display
with the letter “M” for approximately 1 second.
TO CHANGE BETWEEN CELSIUS AND FAHRENHEIT TEMPERATURE READINGS
To change between Celsius and Fahrenheit temperature readings:
Turn the thermometer off and then back on. Continue to press and hold the ON/OFF button for approximately
2seconds. You will see the symbols for °C and °F change.
CLEANING INSTRUCTIONS
1. Clean the thermometer by wiping with a cloth moistened with rubbing alcohol (70% isopropyl alcohol).
2. Wipe again with a clean, water-dampened cloth and let dry.
3. DO NOT IMMERSE THE UNIT IN WATER OR OTHER LIQUIDS. DO NOT BOIL OR CLEAN IN DISHWASHER. DO
NOT WASH THE UNIT WITH THINNER OR ANY CHEMICAL SOLVENT
.
CHANGING THE BATTERIES
The battery in your digital thermometer needs to be replaced when the low-battery indicator symbol ( ) appears
in the lower right corner of your display.Replace the battery with a 1.55V
,LR41 alkaline or SR41 silver oxide type or
equivalent battery. To replace the battery:
1. Gently insert a coin or screwdriver into the slot on the battery cover door and turn to open.
2. Carefully remove the battery with a non-metallic pointed instrument.
3. Do not dispose of used batteries in trash. Properly discard the battery and keep away from young children, pets, and heat.
4. Replace the battery with a 1.55 V, LR41 alkaline or SR41 silver oxide type or equivalent, making sure to insert the
battery with the positive (“+”) side facing up.
5. Replace the battery cover. Your thermometer is now ready for use.
SPECIAL NOTE
If used privately no calibration is needed. For professional use it is recommended to check once a year.
SPECIFICATIONS
Battery Life:More than 200 hours of continuous operation.
T
emperature Range:32.0°C (90.0°F)–42.9°C (109.9°F). If less than 32.0°C, the display will show “Lo”. If more
than 42.9°C, the display will show “Hi”.
TWO YEAR LIMITED GUARANTEE
HoMedics Inc. guarantees this product from defect in material and workmanship for a period of 2 years from the date of purchase, except as noted below. This
HoMedics product guarantee does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorised accessory; alteration to the prod-
uct; or any other conditions whatsoever that are beyond the control of HoMedics. This guarantee is effective only if the product is purchased and operated in the UK.
A product that requires modification or adaptation to enable it to operate in any country other than the country for which it was designed, manufactured, approved
and / or authorised, or repair of products damaged by these modifications are not covered under this guarantee. HoMedics shall not be responsible for any type of
incidental, consequential or special damages.
For all guarantee enquiries please contact HoMedics Customer Service.
This guarantee does not affect your statutory rights.
For more information regarding our product lines, please visit: www.homedics.co.uk
©2007 HoMedics, Inc. and its affiliated companies, all rights reserved. HoMedics® is a registered trademark of HoMedics, Inc.
and its affiliated companies. Supersize DigitsTM is a trademark of HoMedics, Inc and its affiliated companies. All rights reserved.
For HoMedics Customer Service, please contact:
HoMedics, Salter Housewares Ltd, 211 Vale Road, Tonbridge, Kent, TN9 1SU, UK
IB-TOR100GB
FIGURE 2. FIGURE 3.
Accuracy in waterbath:
35.5°C(95.9° F) - 42° C (107.6° F) within the ambient
temperature range: 18°C(64.4°F) - 28° C (82.4° F) ±0.1° C (0.2° F)
<35.5°C(95.9°F) or outside the ambient temperature
range: 18° C (64.4° F) - 28° C (82.4° F) ±0.2° C (0.3° F)
>42° C (107.6° F) or outside the ambient temperature
range: 18° C (64.4° F) - 28° C (82.4° F) ±0.2°C(0.3° F)
Operating Condition:
T
emperature 10°C~40°C (50.0°F~104.0°F)
Humidity 30%~85% RH
Storage Condition:
Temperature -10°C~60°C (14.0°F~140.0°F)
Humidity 25%~90% RH
Table of contents
Other HoMedics Thermometer manuals

HoMedics
HoMedics TE-101 User manual

HoMedics
HoMedics TE-101-EU User manual

HoMedics
HoMedics TT-200 User manual

HoMedics
HoMedics TIE-210 User manual

HoMedics
HoMedics TI-150 User manual

HoMedics
HoMedics JUMBO DISPLAY User manual

HoMedics
HoMedics HTD8216C User manual

HoMedics
HoMedics HTD8816C User manual

HoMedics
HoMedics PG-IRT1603 User manual

HoMedics
HoMedics TU-100 User manual