manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Accessories
  8. •
  9. Honeywell DT8050A User manual

Honeywell DT8050A User manual

DT8050A DUAL TEC
®
Motion Sensor with Anti-Mask - Quick Installation uide
DT8050A DUAL TEC
®
Motion Sensor with Anti-Mask - Quick Installation uide (FR)
DT8050A DUAL TEC
®
Motion Sensor with Anti-Mask - Quick Installation uide (SP)
DT8050A DUAL TEC
®
Motion Sensor with Anti-Mask - Quick Installation uide (P )
1
*
* Keep Clear / Tenir à l'écart /
Respetar obligatoriamente /
Manter-se afastado
*
6' 9" - 8' 9"
(2.1 - 2.7 m)
12”
(30 cm)
7' 6"
(2.3 m)
Optimal
Optimal
Optimal
Optimal
2
3
2
1
3
#6
(3.5 mm)
A
A
A
B B
B B
B B
A
B
#6 x 1 1/4"
(3.5 mm x 32 mm)
X X
4
Microwave Range Adjustment
Réglage de la portée Hyperfréquence
Ajuste del rango de detección Microondas
Ajuste de Alcance Microondas
Enabled
Activé
Habilitado
Habilitado
*Disabled
*Désactivé
*Deshabilitado
*Deshabilitado
* Factory default / Réglage usine /
Defecto de fábrica / Padrão de fábrica
ON
OFF
*
Anti-mask
Anti-masque
Antienmascaramiento
Anti-máscara
MW
SENSITIVITY
MAX
*
MIN
*
LED
Internal EOL Resistor DIP Switches
Résistance interne EOL commutateur DIP
Interruptores DIP internos EOL Resistor
EOL interno Resistor DIP Switches
EOL
KOhm
ON
1 2.2 5.62
*
DT8050A
AM LED
EOL
PULL
TO DISABLE
LOOK DOWN
LOOK DOWN
ON
OFF
ON
W1
MW
SENSITIVITY
MAX
KOhm
ON
1 2 2.2 5.6
DRAFT - QUICK INSTALL GUIDE - 12/10/13
- 2 -
5
24-20 AWG
(0.2-0.52mm2)
2
1
2
Tamper
30 mA
25 VDC
Trouble
30 mA
25 VDC
Power
18 mA
9 - 15 VDC
Alarm
30 mA
25 VDC
LED
0 VDC - Vsupply
1.8 mA max
LED TBL T C V-V+
T NCTBL
9 8 6 4 2 15 37
EOL
KOhm
ON
1 2.2 5.62
EOL
WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES
To connect all three outputs (sensor alarm, tamper and trouble/anti-
mask) to one zone input: All alarm, tamper and trouble/anti-mask
events are “alarms” when the system is armed or “fault” when disarmed.
FR) To connect all three outputs (sensor alarm, tamper and
trouble/anti-mask) to one zone input: All alarm, tamper and
trouble/anti-mask events are “alarms” when the system is armed or “fault”
when disarmed.
ES) To connect all three outputs (sensor alarm, tamper and
trouble/anti-mask) to one zone input: All alarm, tamper and
trouble/anti-mask events are “alarms” when the system is armed or “fault”
whe
n disarmed.
PG) To connect all three outputs (sensor alarm, tamper and
trouble/anti-mask) to one zone input: All alarm, tamper and
trouble/anti-mask events are “alarms” when the system is armed or “fault”
when disarmed.
Zone
COM Ground
Zone
#
Anti-mask
Enabled
+12V
Control Panel
(On-Board, Internal EOLR)
LED TBL T C V
-
V
+
T NCTBL
9 8 6 4 2 15 37
EOL
KOhm
ON
1 2.2 5.62
EOL
ON
Sensor
Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. Keep 12” (30cm) in front
of the sensor clear.
Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. Keep 12” (30cm) in front
of the sensor clear.
Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. Keep 12” (30cm) in front
of the sensor clear.
Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. Keep 12” (30cm) in front
of the sensor clear.
To connect the sensor alarm output to one zone input and the
tamper and trouble/anti-mask outputs to a second zone input: The
alarm relay is wired to one zone; the tamper and trouble/anti-mask are
wired to another zone;
the control panel differentiates alarm conditions
from tamper and trouble/anti-mask conditions.
To connect the sensor alarm output to one zone input and the
tamper and trouble/anti-mask outputs to a second zone input: The
alarm relay is wired to one zone; the tamper and trouble/anti-mask are
wired to another zone; the control panel differentiates alarm conditions
from tamper and trouble/anti-mask conditions.
To connect the sensor alarm output to one zone input and the
tamper and trouble/anti-mask outputs to a second zone input: The
alarm relay is wired to one zone; the tamper and trouble/anti-mask are
wired to another zone; the control panel differentiates alarm conditions
from tamper and trouble/anti-mask conditions.
To connect the sensor alarm output to one zone input and the
tamper and trouble/anti
-mask outputs to a second zone input: The
alarm relay is wired to one zone; the tamper and trouble/anti
-mask are
wired to another zone; the control panel differentia
tes alarm conditions
from tamper and trouble/anti
-mask conditions.
*
Zone
COM Ground +12V
Control Panel
Trouble
Zone
Alarm
Zone
W1
* Off-Board, External EOLR (Not supplied),
best if installed inside the sensor housing.
LED TBL T C V
-
V
+
T NCTBL
9 8 6 4 2 15 37
Cut
Anti-mask
Enabled
EOL
KOhm
ON
1 2.2 5.62
EOL
ON
Sensor
(On-Board, Internal EOLR)
JUMPER
- 3 -
To connect the sensor alarm, tamper and trouble/anti-mask outputs
to three separate zone inputs: The alarm, tamper and trouble/anti-mask
are each wired to a separate zone; the control panel differentiates alarm,
tamper and trouble/anti-mask conditions.
To connect the sensor alarm, tamper and trouble/anti-mask outputs
to three separate zone inputs: The alarm, tamper and trouble/anti-mask
are each wired to a separate zone; the control panel differentiates alarm,
tamper and trouble/anti-mask conditions.
To connect the sensor alarm, tamper and trouble/anti-mask outputs
to three separate zone inputs: The alarm, tamper and trouble/anti-mask
are each wired to a separate zone; the control panel differentiates alarm,
tamper and trouble/anti-mask conditions.
To connect the sensor alarm, tamper and trouble/anti-mask outputs
to three separate zone inputs: The alarm, tamper and trouble/anti-mask
are each wired to a separate zone; the control panel differentiates alarm,
tamper and trouble/anti-mask conditions.
**
Zone
COM Ground +12V
Control Panel
Tamper
Zone
Alarm
Zone
Trouble
Zone
Zone
COM
LED TBL T C V
-
V
+
T NCTBL
9 8 6 4 2 15 37
W1
Cut
Anti-mask
Enabled
EOL
KOhm
ON
1 2.2 5.62
EOL
ON
* Off-Board, External EOLR (Not supplied),
best if installed inside the sensor housing.
Sensor
(On-Board, Internal EOLR)
6
30 sec
30
0
45
20
10
ON
MW
SENSITIVITY
MAX
MIN
AM LED
Walk Test Reset
4X
(slowly)
< 4 ft /1.2m
7
Top View
Vue de dessus
Vista Desde Arriba
Vista Superior
Side View
Vue de coté
Vista Lateral
Vista Lateral 0
0.5
1.85
2.3m
PLAN VIEW
ALL ZONES
7’
2 m
0
0
13’
4 m
20’
6 m
27’
8 m
33’
10 m
40’
12 m
7’
2 m
13’
4 m
20’
6 m
27’
8 m
33’
10 m
40’
12 m
7’
2 m
13’
4 m
20’
6 m
27’
8 m
33’
10 m
40’
12 m 46’
14 m
53’
16 m
7’
2 m
0
13’
4 m
20’
6 m
27’
8 m
33’
10 m
40’
12 m
46’
14 m
53’
16 m
A B C D
LED Power
Up Walk Test Normal Trouble
Anti-
Mask
Red Slow
Blink
ON
Alarm
ON
Alarm
Fast
Blink OFF
Yellow OFF ON
Microwave
ON
Microwave OFF Fast
Blink
reen OFF ON PIR ON PIR OFF OFF
Zones / Zones / Zonas / Zonas
A
2
Look-down / Basses / Vista Zona 0 /
Vigilância inferior
B
12
Lower / Courtes / Cercana/ Mais baixas
C
10
Intermediate / Intermédiaires / Intermedia /
Intermédias
D
36
Long / Longues / Largo Alcance / Longo
alcance
- 4 -
APPROVAL/ LISTINGS:
•FCC part 15, Class B verified
•IC ICES-003, Class B verified
•UL 639
•ULC S306-03
•SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity.
Product must be tested at least once each year.
For appropriate wiring methods, refer to the National Electrical Code NFPA 70 and the Canadian Electrical Code (where applicable).
Power must be provided by a power-limited UL603 Listed burglar alarm power supply with minimum 4 hours of standby power capability, or from a
power-limited output of a UL Listed burglar alarm control unit with minimum 4 hours of standby power capability.
For the latest documentation and online support information, please o to:
Pour de l’assistance en li ne, visitez :
Para recibir soporte en línea, visite:
Para qualquer informação adicional, contacte:
http://www.security.honeywell.com/hsc/resources/MyWebTech/
For the latest U.S. warranty information, please o to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
Pour obtenir de l'information sur la arantie de ce produit, veuillez communiquer avec le représentant autorisé de Honeywell
de votre ré ion.
Por favor contacte con su distribuidor Honeywell Security para información sobre la arantía del producto.
Contacte o representante autorizado Honeywell local para obter informações relativas a arantia.
 2013 Honeywell International Inc. Honeywell and DUAL TEC are re istered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All ri hts reserved. Made in China.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.
Unauthorized changes or modifications could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your
information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the
manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for
a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection
against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions
suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une réception indésirable.
P/N 800-13827 12/13 Rev B
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
www.honeywell.com/security
To protect the environment, a detailed installation uide is available on
the Honeywell website – Please consider before printin the document!

Other Honeywell Accessories manuals

Honeywell C7110A1010 User manual

Honeywell

Honeywell C7110A1010 User manual

Honeywell MyChime RCWL2200A User manual

Honeywell

Honeywell MyChime RCWL2200A User manual

Honeywell 4202 User manual

Honeywell

Honeywell 4202 User manual

Honeywell Y343B1002 User manual

Honeywell

Honeywell Y343B1002 User manual

Honeywell DT8035 Dual Tec User manual

Honeywell

Honeywell DT8035 Dual Tec User manual

Honeywell DT906AM Setup guide

Honeywell

Honeywell DT906AM Setup guide

Honeywell DW915 Series Operating instructions

Honeywell

Honeywell DW915 Series Operating instructions

Honeywell DW315 Series User manual

Honeywell

Honeywell DW315 Series User manual

Honeywell ADEMCO 5821 Quick start guide

Honeywell

Honeywell ADEMCO 5821 Quick start guide

Honeywell Fire-Lite Alarms AD365A User manual

Honeywell

Honeywell Fire-Lite Alarms AD365A User manual

Honeywell R7184A User manual

Honeywell

Honeywell R7184A User manual

Honeywell SHK8M User manual

Honeywell

Honeywell SHK8M User manual

Honeywell TC840ME User manual

Honeywell

Honeywell TC840ME User manual

Honeywell C7772A Service manual

Honeywell

Honeywell C7772A Service manual

Honeywell WPS Series User manual

Honeywell

Honeywell WPS Series User manual

Honeywell Sensepoint User manual

Honeywell

Honeywell Sensepoint User manual

Honeywell RPW206A User guide

Honeywell

Honeywell RPW206A User guide

Honeywell 203365A User manual

Honeywell

Honeywell 203365A User manual

Honeywell MPD Series User manual

Honeywell

Honeywell MPD Series User manual

Honeywell 5898 User manual

Honeywell

Honeywell 5898 User manual

Honeywell SIX Series User manual

Honeywell

Honeywell SIX Series User manual

Honeywell 40003916 Powerhead User manual

Honeywell

Honeywell 40003916 Powerhead User manual

Honeywell 705 Series User manual

Honeywell

Honeywell 705 Series User manual

Honeywell PRO 2000 Series Operation manual

Honeywell

Honeywell PRO 2000 Series Operation manual

Popular Accessories manuals by other brands

Kanlux 04-0011 manual

Kanlux

Kanlux 04-0011 manual

BEKA BA627E instruction manual

BEKA

BEKA BA627E instruction manual

Sigfox WSSFCEX-PPS user guide

Sigfox

Sigfox WSSFCEX-PPS user guide

NORAUTO 2398784 manual

NORAUTO

NORAUTO 2398784 manual

TaoTronics TT-AD001 user manual

TaoTronics

TaoTronics TT-AD001 user manual

Hunter 43758 instruction manual

Hunter

Hunter 43758 instruction manual

Manitowoc 7623123 user manual

Manitowoc

Manitowoc 7623123 user manual

Brother BAS-311E instruction manual

Brother

Brother BAS-311E instruction manual

GENERAL MOBILE GM Smart Plug user manual

GENERAL MOBILE

GENERAL MOBILE GM Smart Plug user manual

Panasonic Light Emitting Diodes LN222RPX Specifications

Panasonic

Panasonic Light Emitting Diodes LN222RPX Specifications

Oricom OBHAD200 user guide

Oricom

Oricom OBHAD200 user guide

Leuze electronic PRK3CLA Autokollimation manual

Leuze electronic

Leuze electronic PRK3CLA Autokollimation manual

Exabyte MAGNUM 1X7 LTO AUTOLOADER product manual

Exabyte

Exabyte MAGNUM 1X7 LTO AUTOLOADER product manual

Tektronix TPR1000 user manual

Tektronix

Tektronix TPR1000 user manual

IMMAX NEO SMART user manual

IMMAX

IMMAX NEO SMART user manual

ICARO paragliders XEMA 2 manual

ICARO paragliders

ICARO paragliders XEMA 2 manual

Razer RC21-0179 Information guide

Razer

Razer RC21-0179 Information guide

Omcan BD-CN-0007-HC instruction manual

Omcan

Omcan BD-CN-0007-HC instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.