2 Honeywell Sensing and Control
Quick Start Guide for the
WPS Series Wireless Pressure Sensor
ISSUE 1 50095585
1.3 Certications and Approvals
1.3.1 Hazardous Location Certifications
Table 2. Certications and Approvals
Agency Type of Protection Ambient Temperature Product Applicability*
CSA
1903673
(USA and
Canada)
Intrinsically Safe:
Class I; Division 1; Groups A, B, C, D;
Class II, Division 1, Groups E, F, G;
Class III, Division 1; T4
Class I, Zone 0 Ex ia IIC T4
Class I, Zone 0 AEx ia IIC T4
-40 °C to +85 °C : Battery
-40 °C to +80 °C : dc Supply
Pressure
Temperature/ Discrete Inputs
Corrosion
High Level INPUT (HLAI)
Universal I/O
Nonincendive:
Class I; Division 2; Groups A, B, C, D;
Class II, Division 2, Groups F, G;
Class III, Division 2, T4
Class I, Zone 2 Ex nA IIC, T4
Class I, Zone 2 AEx nA IIC, T4
-40 °C to +85 °C : Battery
-40 °C to +80 °C : dc Supply
Pressure
Temperature/ Discrete Inputs
High Level INPUT (HLAI)
Universal I/O
Explosion-Proof/ Flameproof:
Class I, Division 1; Groups A, B, C, D;
Class II, Division 1, Groups E, F, G;
Class III, Division 1; T4
Class I, Zone 1 Ex d IIC T4
Class I, Zone 1 AEx d IIC, T4
-40 °C to +85 °C : Battery
-40 °C to +80 °C : dc Supply
Pressure
Temperature/ Discrete Inputs
Corrosion
High Level INPUT (HLAI)
Universal I/O
Enclosure Type: Type 4X, IP 66
Standards Used:
CSA-C22.2 No. 30:M1986
CSA-C22.2 No. 94:M1991
CSA E60079-0: 2002
CSA E60079-15: 2002
FM 3600: 1998
FM 3615: 2006
UL 916:1998
CSA-C22.2 No. 142:M1987
CSA-C22.2 No. 157:M1992
CSA E60079-1: 2002
CSA E61241-0: 2002
FM 3610: 1999
ANSI/ ISA 12.12.02: 2003
CSA-C22.2 No. 213:M1987
CSA-C22.2 No. 60529:2005
CSA E60079-11: 2002
CSA E61241-1: 2002
FM 3611: 2004
UL 50:2003
FM
ApprovalsTM
3032450
(USA)
Intrinsically Safe:
Class I; Division 1; Groups A, B, C, D;
Class II, Division 1, Groups E, F, G;
Class III, Division 1; T4
Class I, Zone 0 AEx ia IIC T4
-40 °C to +85 °C : Battery
-40 °C to +80 °C : dc Supply
Pressure
Temperature/ Discrete Inputs
Corrosion
High Level INPUT (HLAI)
Universal I/O
Nonincendive:
Class I; Division 2; Groups A, B, C, D;
Class II, Division 2, Groups F, G;
Class III, Division 2, T4
Class I, Zone 2 AEx nA IIC, T4
-40 °C to +85 °C : Battery
-40 °C to +80 °C : dc Supply
Pressure
Temperature/ Discrete Inputs
High Level INPUT (HLAI)
Universal I/O
Explosion-Proof/ Flameproof:
Class I, Division 1; Groups A, B, C, D;
Class II, Division 1, Groups E, F, G;
Class III, Division 1; T4
Class I, Zone 1 AEx d IIC, T4
-40 °C to +85 °C : Battery
-40 °C to +80 °C : dc Supply
Pressure
Temperature/ Discrete Inputs
Corrosion
High Level INPUT (HLAI)
Universal I/O
Enclosure Type: Type 4X, IP 66
Standards Used:
FM 3600:1998
FM 3615:2006
ANSI/ ISA 12.02.01: 2002
ANSI/ IEC 60529: 2004
FM 3610: 2007
FM 3810: 2005
ANSI/ ISA 12.12.02: 2003
ANSI/ NEMA 250: 2003
FM 3611: 2004
ANSI/ ISA 12.00.01: 2002
ANSI/ ISA 12.22.01: 2005