Honeywell Ex-Or MLS Series Quick start guide

CDW12U5 Programmable Connection Centres and
CDH4U5/CDH8U5 Hard-Wired Intelligent Lighting Control
Modules support a range of dedicated high-performance
presence detectors. Detectors contain a photocell to
monitor total light levels, allowing the light output of
dimmable luminaires to be adjusted to suit the natural light
level available.
The range of detectors for remote mounting encompasses
both PIR and Microwave technology:
o
MLS2001CDR - 360 PIR presence detection
o
MLS2401CDR - 360 microwave presence detection
MLS2500CDR - directional microwave presence detection
All contain an infrared port that can be used both for local
control from a hand-held device when in service and for
initial commissioning of the CDW12U5/CDH4U5/CDH8U5
Intelligent LCM system.
Detectors connect to the LCM via RJ45 patch leads and all
are SELV devices when properly installed and connected.
Ready-made patch leads are available in lengths of 3m,
5m and 10m.
Commissioning
With the CDW12U5 and CDH4U5/CDH8U5 LCM systems,
all configuration information is held within the Connection
Centre itself, not the individual detectors. Most of the
parameters are set up with the aid of a dedicated
progamme running on a portable PC which communicates
with the LCM either by an infrared link, via one of the
attached detectors, or by a specialised serial link into the
LCM itself.
When setting the actual light levels around which dimming
or switching decisions are made, the system utilises the
same simple and convenient method as used for Ex-Or’s
traditional stand-alone detectors. An infrared programming
tool (HP2000 or HC5) is used to set the controlling or
switching set-point for the photocell. The setting is then
transmitted from the detector to the LCM where it is
uniquely associated with that particular detector. The
setting will be preserved in the event of power failure. All
settings can be re-programmed any number of times.
(See ‘Setting the Regulating Photocell’ and ‘Setting the
Switching Photocell’ sections of installation instructions for
details of setting procedure.)
Connect - Lighting control modules and plug-in connection centres
Please check www.ex-or.com to ensure this is the most
recent issue - Ref: D4123B
Ex-Or, Haydock Lane, Haydock, Merseyside WA11 9UJ
T: +44 (0)1942 719229 F: +44 (0)1942 272767 E: technicalsales.ex-or@honeywell.com & orders.ex-or@honeywell.com www.ex-or.com
MLS Connect Digital Remote Detectors
for CDW12U5, CDH4U5 & CDH8U5 LCMs
MLS2001CDR
MLS2500CDR
MLS2401CDR
Surface-mount versions
also available (suffix SM)
Positioning, Fixing & Connections
Technical Data
Accessories
Dimensions
HC5 Universal Hand-held Controller
Allows manual override.
Ex-Or operates a genuine policy of continuous improvement. You may expect the specification to be regularly enhanced. For latest technical information, please visit www.ex-or.com.
Ref: D4123B
Part Numbers
o
MLS2001CDR 360 PIR Detector - flush
o
MLS2001CDRSM 360 PIR Detector - surface
o
MLS2401CDR 360 Microwave Detector - flush
o
MLS2401CDRSM 360 Microwave Detector - surface
MLS2500CDR Directional Microwave Detector - semi-flush
MLS2500CDRSM Directional Microwave Detector - surface
BT5E030GY 3m Detector Patch Lead
BT5E050GY 5m Detector Patch Lead
BT5E100GY 10m Detector Patch Lead
HP2000 MLS Digital Programmer
HC5 Universal Hand-held Controller c/w wall bracket
MLS2001CDR & MLS2401CDR
MAX RECOMMENDED MOUNTING HEIGHT: 3.0m
RANGE: Cone-shaped detection pattern. Diameter (at floor level) =
2.4 x mounting height (MLS2001CDR) 2.8 x mounting height (MLS2401CDR)
OPERATING VOLTAGE: 12V DC, SELV if installed correctly
PHOTOCELL: Regulating
DEPTH REQUIRED BEHIND CEILING (FLUSH VERSIONS):
62mm plus an allowance for the minimum bend radius of the patch lead
WEIGHT: 170g approx - MLS2001CDR
200g approx - MLS2401CDR
COLOUR: White
MATERIAL: Flame retardant PC/ABS
IP RATING: 3X - MLS2001CDR
2X - MLS2401CDR
6.0m
2.5m
7.0m
2.5m
MLS2500CDR
MAX RECOMMENDED MOUNTING HEIGHT: 3.5m
RANGE: Adjustable up to 20m
OPERATING VOLTAGE: 12V DC, SELV if installed correctly
PHOTOCELL Regulating
DEPTH REQUIRED BEHIND CEILING (SEMI-FLUSH VERSION):
40mm plus an allowance for the minimum bend radius of the patch lead
WEIGHT: 130g approx
COLOUR: White
MATERIAL: Flame retardant PC/ABS
IP RATING: 4X
MLS2001CDR MLS2401CDR
II I
II
Ex-Or
Haydock Lane
Haydock
Merseyside
WA11 9UJ
Tel: 01942 719229
Fax: 01942 272767
To CD
Box
Do Not
Connect
Do Not
Connect
Bayonet Fixing
Lugs
Socket for
Patch Lead to
LCM
View on back of
MLS2001CDR
MLS2401CDR
Detectors
Socket for
Patch Lead to
LCM
Arrow Symbol
View on Back of
MLS2500CDR
Detector
Locking
Screw
To CD
Box
Do Not
Connect
No Serviceable Parts Inside.
DO NOT OPEN
Power consumption <10W
II I
I
ta 0..40 C
Bayonet Tab
Receptacles
I
MLS2500CDR
60
95
50.8
74
20mm
back
entry
Rear View
Positioning Notes
Do not mount within 0.25m of a luminaire.
The MLS2401CDR should not be positioned on a pitch narrower than 5m.
Microwave detectors (MLS2401CDR & MLS2500CDR) are extremely sensitive to movement and
must be installed on a rigid surface that will not itself be subject to movement. Microwaves can
penetrate lightly built partitions, glass etc and thus movement in adjacent spaces can cause
spurious triggering if the orientation and sensitivity settings of the detector are not carefully
managed. They are not recommended for areas where there are large areas of metal such as
metal ceiling panels as unpredictable sensitivity may result.
Fixing (Outline guidance - see installation instructions for full details)
MLS2001CDR & MLS2401CDR
Flush Versions - Depth required behind ceiling: 62mm from front flange plus an allowance for the
minimum bend radius of the cable. Sinking box fits into a 89mm diameter hole in ceiling tile or
plasterboard ceiling. To avoid damage to ceiling tile, do not overtighten. No access above the
ceiling is necessary. The unit fits into the housing with a simple bayonet action.
Surface Versions - The housing may be secured to a hard surface or a BESA box. The unit fits into
the housing with a simple bayonet action.
MLS2500CDR
Semi-flush Version - Use a hole saw to drill a 76mm hole into the ceiling tile. The flush ring is
designed to clamp the tile between its two halves.
Surface Version - The back-box can be secured directly to a hard surface or to a conduit stop
end box.
62mm
deep
62mm deep
behind ceiling
100mm
MLS2001CDR MLS2001CDRSM
Flange:
10mm
deep
100mm
62mm
deep
100mm
100mm
MLS2401CDR MLS2401CDRSM
Flange:
15mm
deep
62mm deep
behind ceiling
MLS2500CDR
HP2000 MLS Digital Programmer
Menu-driven LCD Programmer with
automatic equipment recognition and
parameter download facilities.

This manual suits for next models

3

Other Honeywell Security Sensor manuals

Honeywell IS2535T User manual

Honeywell

Honeywell IS2535T User manual

Honeywell Friedland FGGA03 Series User manual

Honeywell

Honeywell Friedland FGGA03 Series User manual

Honeywell C7076F User manual

Honeywell

Honeywell C7076F User manual

Honeywell NFPA 1971 Owner's manual

Honeywell

Honeywell NFPA 1971 Owner's manual

Honeywell PANORAMA Series User manual

Honeywell

Honeywell PANORAMA Series User manual

Honeywell Sensepoint XCD RFD Release Note

Honeywell

Honeywell Sensepoint XCD RFD Release Note

Honeywell SiX Series User manual

Honeywell

Honeywell SiX Series User manual

Honeywell Eclipse Instruction Manual

Honeywell

Honeywell Eclipse Instruction Manual

Honeywell Small SATCOM Instruction Manual

Honeywell

Honeywell Small SATCOM Instruction Manual

Honeywell CLLRF2OCR2BP User manual

Honeywell

Honeywell CLLRF2OCR2BP User manual

Honeywell PEHA D MLS2500CDRR4 Installation and operation manual

Honeywell

Honeywell PEHA D MLS2500CDRR4 Installation and operation manual

Honeywell Miller 8172 Operator's manual

Honeywell

Honeywell Miller 8172 Operator's manual

Honeywell PEHA MLS Digital Hi-Bay D MLS2001AHBF Installation and operation manual

Honeywell

Honeywell PEHA MLS Digital Hi-Bay D MLS2001AHBF Installation and operation manual

Honeywell FSL100-IR3 Release Note

Honeywell

Honeywell FSL100-IR3 Release Note

Honeywell Connected Home DO8EZS User manual

Honeywell

Honeywell Connected Home DO8EZS User manual

Honeywell IS312B User manual

Honeywell

Honeywell IS312B User manual

Honeywell ESSER 784763 User manual

Honeywell

Honeywell ESSER 784763 User manual

Honeywell FS24X User manual

Honeywell

Honeywell FS24X User manual

Honeywell 5800CO Assembly instructions

Honeywell

Honeywell 5800CO Assembly instructions

Honeywell Viewguard DUAL AM FAI Instruction manual

Honeywell

Honeywell Viewguard DUAL AM FAI Instruction manual

Honeywell 5800PIR-RES User manual

Honeywell

Honeywell 5800PIR-RES User manual

Honeywell 5897-35 User manual

Honeywell

Honeywell 5897-35 User manual

Honeywell Filtrex TC844A1007 User manual

Honeywell

Honeywell Filtrex TC844A1007 User manual

Honeywell FF-SB12 Series User manual

Honeywell

Honeywell FF-SB12 Series User manual

Popular Security Sensor manuals by other brands

ANATEL LN-104C EMF Instructions and warnings for installation and use

ANATEL

ANATEL LN-104C EMF Instructions and warnings for installation and use

Eaton HaloHome MST20C18W instruction manual

Eaton

Eaton HaloHome MST20C18W instruction manual

Camp Safety GOBLIN manual

Camp Safety

Camp Safety GOBLIN manual

SORHEA G-WALL installation manual

SORHEA

SORHEA G-WALL installation manual

Camp Safety SWIFTY VEST manual

Camp Safety

Camp Safety SWIFTY VEST manual

Eaton 2450 Series manual

Eaton

Eaton 2450 Series manual

Carrier DET-TRONICS Dual Spectrum PM-5MPX instructions

Carrier

Carrier DET-TRONICS Dual Spectrum PM-5MPX instructions

MAXIMUM Security CURTAIN-FLT manual

MAXIMUM Security

MAXIMUM Security CURTAIN-FLT manual

Petzl Croll manual

Petzl

Petzl Croll manual

Velleman VTTEST18 user manual

Velleman

Velleman VTTEST18 user manual

Maxouttech RF-RDWS-345-NN installation instructions

Maxouttech

Maxouttech RF-RDWS-345-NN installation instructions

Tinker & Rasor M/1 Product instructions

Tinker & Rasor

Tinker & Rasor M/1 Product instructions

Abus AirSecure CO2WM110 user manual

Abus

Abus AirSecure CO2WM110 user manual

Abus FUMK50020 installation instructions

Abus

Abus FUMK50020 installation instructions

Ono Sokki FP-4135 instruction manual

Ono Sokki

Ono Sokki FP-4135 instruction manual

DF ROBOT SEN0545 user manual

DF ROBOT

DF ROBOT SEN0545 user manual

Fantini Cosmi Sicurgas P63 manual

Fantini Cosmi

Fantini Cosmi Sicurgas P63 manual

TECHNO-AC Success CBI-116N operating instructions

TECHNO-AC

TECHNO-AC Success CBI-116N operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.