manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security Sensor
  8. •
  9. Honeywell Notifier FST-851 Series User manual

Honeywell Notifier FST-851 Series User manual

This manual suits for next models

6

Other Honeywell Security Sensor manuals

Honeywell EC-FX-NH3 Manual

Honeywell

Honeywell EC-FX-NH3 Manual

Honeywell SiXGB User manual

Honeywell

Honeywell SiXGB User manual

Honeywell C7061A Operation manual

Honeywell

Honeywell C7061A Operation manual

Honeywell FS24X User manual

Honeywell

Honeywell FS24X User manual

Honeywell Ex-Or LS3043DR User manual

Honeywell

Honeywell Ex-Or LS3043DR User manual

Honeywell 5800PIR-RES User manual

Honeywell

Honeywell 5800PIR-RES User manual

Honeywell HS3PIR1X User manual

Honeywell

Honeywell HS3PIR1X User manual

Honeywell Miller TurboLite Series Operator's manual

Honeywell

Honeywell Miller TurboLite Series Operator's manual

Honeywell Miller Falcon MP50G-LE Installation instructions

Honeywell

Honeywell Miller Falcon MP50G-LE Installation instructions

Honeywell DT7235T User manual

Honeywell

Honeywell DT7235T User manual

Honeywell Ex-Or MLS2000DF Installation and operation manual

Honeywell

Honeywell Ex-Or MLS2000DF Installation and operation manual

Honeywell SiXCOMBO User manual

Honeywell

Honeywell SiXCOMBO User manual

Honeywell NOTIFIER IRX-751CTEM User manual

Honeywell

Honeywell NOTIFIER IRX-751CTEM User manual

Honeywell C08MS User manual

Honeywell

Honeywell C08MS User manual

Honeywell 5809 User manual

Honeywell

Honeywell 5809 User manual

Honeywell C7007A User manual

Honeywell

Honeywell C7007A User manual

Honeywell PROINDMV Assembly instructions

Honeywell

Honeywell PROINDMV Assembly instructions

Honeywell EXCEL ADT-HRSI User manual

Honeywell

Honeywell EXCEL ADT-HRSI User manual

Honeywell PEHA LightSpot Mid Range Series Installation and operation manual

Honeywell

Honeywell PEHA LightSpot Mid Range Series Installation and operation manual

Honeywell C7076D Operation manual

Honeywell

Honeywell C7076D Operation manual

Honeywell SC105 User manual

Honeywell

Honeywell SC105 User manual

Honeywell CLLRF2OCR2BP User manual

Honeywell

Honeywell CLLRF2OCR2BP User manual

Honeywell BW Ultra User manual

Honeywell

Honeywell BW Ultra User manual

Honeywell Friedland FGGA08 Series User manual

Honeywell

Honeywell Friedland FGGA08 Series User manual

Popular Security Sensor manuals by other brands

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

urmet domus 1083 manual

urmet domus

urmet domus 1083 manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

Rielta Ladoga MK-RK installation guide

Rielta

Rielta Ladoga MK-RK installation guide

Mirion Technologies ACCURAD PRD user manual

Mirion Technologies

Mirion Technologies ACCURAD PRD user manual

Bosch DS835 installation instructions

Bosch

Bosch DS835 installation instructions

Lamptime ST05C instructions

Lamptime

Lamptime ST05C instructions

Ubiquiti MFI-MSC quick start guide

Ubiquiti

Ubiquiti MFI-MSC quick start guide

Subsite 910R Support

Subsite

Subsite 910R Support

Satel OPAL Pro manual

Satel

Satel OPAL Pro manual

Aleph XC-1XTEU manual

Aleph

Aleph XC-1XTEU manual

Pima LARIS QUAD installation instructions

Pima

Pima LARIS QUAD installation instructions

Solinst 301 user guide

Solinst

Solinst 301 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

dn-6936:a1 • 06/8/09 — Page 1 of 2
FST-851 Series
Intelligent Thermal (Heat) Detectors
with FlashScan®
Intelligent / Addressable Devices
dn-6936:a1 • H-211
General
Notifier FST-851 Series intelligent plug-in thermal detectors
with integral communication has features that surpass conven-
tional detectors. Point ID capability allows each detector’s
address to be set with decade address switches, providing
exact detector locations. FST-851 Series thermal detectors
use an innovative thermistor sensing circuit to produce 135°F/
57°C fixed-temperature (FST-851) and rate-of-rise thermal
detection (FST-851R) in a low-profile package. FST-851H pro-
vides fixed high-temperature detection at 190°F/88°C. These
thermal detectors provide effective, intelligent property protec-
tion in a variety of applications. FST-851 Series detectors are
compatible with all Notifier intelligent Fire Alarm Control Pan-
els, except FireWarden series panels. .
FlashScan® (U.S. Patent 5,539,389) is a communication pro-
tocol developed by Notifier Engineering that greatly enhances
the speed of communication between analog intelligent
devices and certain NOTIFIER systems. Intelligent devices
communicate in a grouped fashion. If one of the devices within
the group has new information, the panel’s CPU stops the
group poll and concentrates on single points. The net effect is
response speed greater than five times that of earlier designs.
Features
• Sleek, low-profile, stylish design.
• State-of-the-art thermistor technology for fast response.
• Rate-of-rise model (FST-851R), 15°F (8.3°C) per minute.
• Factory preset at 135°F (57°C); high-temperature model at
190°F (88°C).
• Addressable by device.
• Compatible with FlashScan® and CLIP protocol systems.
• Direct dial entry of address 01-159 for FlashScan® loops,
01-99 CLIP mode loops.
• Two-wire SLC connection.
• Visible LEDs “blink” every time the unit is addressed.
• 360°-field viewing angle of the visual alarm indicators (two
bi-color LEDs). LEDs blink green in Normal condition and
turn on steady red in Alarm.
• Integral communications and built-in device-type identifica-
tion.
• Remote test feature from the panel.
• Built-in functional test switch activated by external magnet.
• Walk test with address display (an address of 121 will blink
the detector LED 12-(pause)-1).
• Low standby current.
• Backward-compatible.
• Built-in tamper-resistant feature.
• Designed for direct-surface or electrical-box mounting.
• Sealed against back pressure.
• Plugs into separate base for ease of installation and main-
tenance. Separate base allows interchange of photoelec-
tric, ionization and thermal sensors.
• SEMS screws for wiring of the separate base.
• Constructed of off-white Bayblend®, designed to commer-
cial standards, and offers an attractive appearance.
• 94-5V plastic flammability rating.
• Remote LED output connection to optional RA400Z remote
LED annunciator.
• Optional sounder, relay, and isolator bases.
• Optional recessed (RMK400) or surface (SMK400E) base
mounting kits.
Specifications
Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in
B501 base, 6.1" (15.5 cm) diameter installed in B710LP base.
Shipping weight: 4.8 oz. (137 g).
Operating temperature range: FST-851 Series, FST-851R: –
20°C to 38°C (–4°F to 100°F); FST-851H: –20°C to 66°C (–4°F
to 150°F).
Detector spacing: UL approved for 50 ft. (15.24 m) center to
center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing.
Relative humidity: 10% – 93% noncondensing.
Thermal ratings: fixed-temperature setpoint 135°F (57°C),
rate-of-rise detection 15°F (8.3°C) per minute, high tempera-
ture heat 190°F (88°C).
Altitude rating: 10,000 feet.
ELECTRICAL SPECIFICATIONS:
Voltage rang e: 15 - 32 volts DC peak.
Standby current (max. avg.): 300 μA @ 24 VDC (one com-
munication every 5 seconds with LED enabled).
LED current (max.): 6.5 mA @ 24 VDC (“ON”).
BASES AVAILABLE:
B710LP: 6.1" (15.5 cm) diameter.
B501: 4.1" (10.4 cm) diameter.
B501BH-2 or B501BHT-2: Sounder base assembly.
B224RB Relay Base: Screw terminals: up to 14 AWG (2.0
mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive;
0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive.
Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm).
B224BI Isolator Base: Dimensions: 6.2" (15.748 cm) x 1.2"
(15.748 cm). Maximum: 25 devices between isolator bases.
See Note 2 under Installation.
Applications
Use thermal detectors for protection of property. For further
information, go to systemsensor.com for manual I56-407-00,
Applications Manual for System Smoke Detectors, which pro-
FST-851 Series in B710LP base
6936pho1.jpg
Page 2 of 2 — dn-6936:a1 • 06/8/09
Notifier® and FlashScan® are a registered trademark of Honeywell International Inc.
Bayblend® is a registered trademark of Bayer Corp.
©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this docu-
ment is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com
Made in the U.S. A.
vides detailed information on detector spacing, placement,
zoning, wiring, and special applications.
Installation
The FST Series plug-in intelligent thermal detector uses a sep-
arate base to simplify installation, service, and maintenance.
Installation instructions are shipped with each detector.
Mount base (all base types) on an electrical backbox which is
at least 1.5" (3.81 cm) deep. Suitable boxes include:
• 4.0" (10.16 cm) square box.
• 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box.
• Single-gang box (except relay or isolator base).
• With B501BH-2 or B501BHT-2 base, use a 4.0" (10.16 cm)
square box.
• With B224RB or B224BI base, use a 3.5" (8.89 cm) or 4.0"
(10.16 cm) octagonal box, or a 4.0" (10.16 cm) square box.
NOTE: 1) Because of the inherent supervision provided by the
SLC loop, end-of-line resistors are not required. Wiring “T-taps” or
branches are permitted for Style 4 (Class “B”) wiring. 2) When
using relay or sounder bases, consult data sheet DN-2243 (ISO-X)
for device limitations between isolator modules and isolator bases.
Agency Listings and Approvals
These listings and approvals apply to the modules specified in
this document. In some cases, certain modules or applications
may not be listed by certain approval agencies, or listing may
be in process. Consult factory for latest listing status.
•UL Listed: S747
•ULC Listed: S6978MEA Listed: 383-02-E
• FM Approved
•CSFM: 7270-0028:196
•BSMI: CI313066760025
•CCCF: Certif. # 2004081801000018
•U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3
(AFP1010/AM2020); 161.002/42/1 (NFS-640)
•Lloyd’s Register: 03/60011
Product Line Information
“A” suffix indicates ULC Listed model.
FST-851: Intelligent thermal detector. Must be mounted to one
of the bases listed below.
FST-851A:
Same as FST-851 but with ULC Listing.
FST-851R:
Intelligent thermal detector with rate-of-rise feature.
FST-851RA
: Same as FST-851R but with ULC Listing.
FST-851H:
Intelligent high-temperature thermal detector.
FST-851HA:
Same as FST-851H but with ULC Listing.
BASES:
B710LP: Standard U.S. low-profile base
B710LPBP:
Standard U.S. low-profile base, pkg. of 10.
B710LP:
Standard U.S. low-profile base.
B710LP(A):
Standard U.S. low-profile base.
B501BP: Standard European flangeless base, pkg. of 10.
B501: Standard European flangeless base.
B501(A): Standard European flangeless base, ULC Listing.
BH501BH-2: Sounder base, includes B501base above.
BH501BHT-2:
Same as B501BH-2, but includes temporal sounder.
BH501BHA: Sounder base, includes B501base above
BH501BHTA:
Same as BH501BHA, but includes temporal sounder.
B224BI(A): Intelligent isolator base. Isolates SLC from loop
shorts.
ACCESSORIES:
F110: Retrofit replacement flange for older style high profile
bases. Converts bases for use with FlashScan® detectors.
RA400Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S.
single-gang electrical box. Supported by B710LPBP(A) and
B501(A) bases only.
SMK400E: Surface mounting kit provides for entry of surface
wiring conduit. For use with B501(A) base only.
RMK400: Recessed mounting kit. For use with B501(A) base
only.
SMB600:
Surface mounting kit for use with B710LPBP(A).
BCK-200B: Black detector covers, box of 10.
M02-04-00: Test magnet.
M02-09-00: Test magnet with telescope stick.
XR2B: Detector removal tool. Allows installation and/or
removal of FlashScan® Series detector heads from base in
high ceiling installations.
T55-127-010: Detector removal tool without pole.
XP-4: Extension pole for XR2B. Comes in three 5-ft. sections.