LAQUAtwin series (pH/ISE type) Before Use 12017 HORIBA Advanced Techno Co., Ltd.
Instruction Manual (Before Use)
COMPACT WATER QUALITY METER
LAQUAtwin series (pH/ISE type)
Preface
This manual describes things to be known before
using the COMPACT WATER QUALITY METER,
LAQUAtwin series.
Be sure to read this manual before using the
product to ensure proper and safe operation of
the instrument. Also safely store the manual so it
is readily available for reference whenever nec-
essary.
Product specifications and appearance, as well
as the contents of this manual are subject to
change without notice.
Warranty and responsibility
HORIBA Advanced Techno Co., Ltd. warrants
that the Product shall be free from defects in
material and workmanship and agrees to repair
or replace free of charge, at option of HORIBA
Advanced Techno Co., Ltd., any malfunctioning
or damaged Product attributable to responsibility
of HORIBA Advanced Techno Co., Ltd. for a
period of two (2) years from the delivery. How-
ever, the warranty period of sensor is 6 months.
In addition, the warranty applies only when the
sensor repeatedly fails even after cleaning and
conditioning. In the following cases, none of the
warranties is valid;
Any malfunction or damage attributable to
improper operation
Any malfunction attributable to attempted
repair or modification by any person not autho-
rized by HORIBA Advanced Techno Co., Ltd.
Any malfunction or damage attributable to vio-
lation of the instructions in this manual or oper-
ations in an environment and the manner not
specified in this manual
Any malfunction or damage attributable to any
cause or causes beyond the reasonable con-
trol of HORIBA Advanced Techno Co., Ltd.
such as natural disasters
Any deterioration in appearance attributable to
corrosion, rust, and so on
Replacement of consumables such as the
standard solutions
HORIBA Advanced Techno Co., Ltd. SHALL
NOT BE LIABLE FOR ANY DAMAGES RESULT-
ING FROM ANY MALFUNCTIONS OF THE
PRODUCT, ANY ERASURE OF DATA, OR ANY
OTHER USES OF THE PRODUCT.
Trademarks
Company names and brand names are either
registered trademarks or trademarks of the
respective companies. (R), (TM) symbols may be
omitted in this manual.
Regulations
EU regulations
Conformable standards
This equipment conforms to the following stan-
dards:
Information on disposal of electrical and elec-
tronic equipment and disposal of batteries
and accumulators
The crossed out wheeled bin symbol with under-
bar shown on the product or accompanying docu-
ments indicates the product requires appropriate
treatment, collection and recycle for waste elec-
trical and electronic equipment (WEEE) under
the Directive 2012/19/EU, and/or waste batteries
and accumulators under the Directive 2006/66/
EC in the European Union.
The symbol might be put with one of the chemical
symbols below. In this case, it satisfies the
requirements of the Directive 2006/66/EC for the
object chemical.
This product should not be disposed of as
unsorted household waste.
Your correct disposal of WEEE, waste batteries
and accumulators will contribute to reducing
wasteful consumption of natural resources, and
protecting human health and the environment
from potential negative effects caused by hazard-
ous substance in products.
Contact your supplier for information on applica-
ble disposal methods.
Authorised representative in EU
HORIBA UK Limited
2 Dalston Gardens, Stanmore, Middlesex HA7
1BQ GREAT BRITAIN UK
FCC rules
Any changes or modifications not expressly
approved by the party responsible for compliance
shall void the user's authority to operate the
equipment.
Warning
This equipment has been tested and found to
comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These lim-
its are designed to provide reasonable protection
against harmful interference when the equipment
is operated in a commercial environment. This
equipment generates, uses, and can radiate
radio frequency energy and, if not installed and
used in accordance with the instruction manual,
may cause harmful interference to radio commu-
nications.
Operation of this equipment in a residential area
is likely to cause harmful interference in which
case the user will be required to correct the inter-
ference at his own expense.
Korea certification
B급 기기 ( 가정용 방송통신기자재 )
이 기기는 가정용(B급) 전자파적합기기로서 주로
가정에서 사용하는 것을 목적으로 하며 , 모든
지역에서 사용할 수 있습니다 .
Taiwan battery recycling mark
China regulation
California regulations
CR Coin Lithium Battery contains Perchlorate
Material – special handling may apply.
See http://www.dtsc.ca.gov/hazardouswaste/per-
chlorate
EMC: EN61326-1
Class B, Portable test and measure-
ment equipment
RoHS: EN50581
9. Monitoring and control instruments
Warning:
This product is not intended for use in industrial envi-
ronments. In an industrial environment, electromag-
netic environmental effects may cause the incorrect
performance of the product in which case the user
may be required to take adequate measures.
ḽ䇦Ⲻᝅѿ
ᵢḽ䇦䘸⭞൞ѣ঄Ӱ≇ާૂള䬶୤⭫ಞ⭫ᆆӝ
૷θḽ䇦ѣཤⲺᮦᆍ㺞⽰⧥ູؓᣚֵ⭞ᵕ䲆Ⲻᒪ
ᮦȾ(уᱥ㺞⽰ӝ૷䍞䠅ؓ䇷ᵕ䰪Ⱦ) 㾷䚫ᆾ
䘏Ѡӝ૷ᴿީⲺᆿޞૂֵ⭞⌞ᝅӁ亯θԄ࡬䙖ᰛ
ᔶခ㇍䎭൞䘏Ѡᒪ䲆޻θуՐ㔏⧥ູ⊗ḉȽӰ։
ૂ䍘ӝᑜᶛћ䠃ⲺᖧଃȾ䈭у㾷䳅ᝅᓕᔹᵢ⭫ಞ
⭫ᆆӝ૷Ⱦ
ӝ૷ѣᴿᇩ⢟䍞Ⲻ〦䠅
䜞Ԭ〦
ᴿᇩ⢟䍞
䫻
(Pb)
⊔
(Hg)
䭿
(Cd)
ޣԭ䬢
(Cr (VI))
ཐ⓪㚊㤥
(PBB)
ཐ⓪ӂ㤥䟐
(PBDE)
ᵢ։ ۑۑۑۑۑ
⭫⊖ ۑۑۑۑۑ
Ֆ᝕ಞ ۑۑۑۑ
ᵢ㺞ṲדᦤSJ/T 11364Ⲻ㿺ᇐ㕌࡬Ⱦ
ۑ: 㺞⽰䈛ᴿᇩ⢟䍞൞䈛䜞Ԭᡶᴿൽ䍞ᶆᯏѣⲺ䠅ൽ൞ GB
/T
26572 㿺ᇐⲺ䲆䠅㾷≸ԛсȾ
: 㺞⽰䈛ᴿᇩ⢟䍞㠩ቇ൞䈛䜞ԬⲺḆжൽ䍞ᶆᯏѣⲺ䠅䎻࠰
GB/T 26572 㿺ᇐⲺ䲆䠅㾷≸Ⱦ
LAQUAtwin series (pH/ISE type) Before Use 2CODE: GZ0000460291
For Your Safety
Hazard classification and warning sym-
bols
Warning messages are described in the following
manner. Read the messages and follow the
instructions carefully.
Hazard classification
Warning symbols
Safety precautions Handling precautions
This indicates an imminently hazardous situation
which, if not avoided, will result in death or serious
injury. This is to be limited to the most extreme situa-
tions.
This indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
This indicates a potentially hazardous situation
which, if not avoided, may result in minor or moder-
ate injury. It may also be used to alert against unsafe
practices.
Description of what should be done, or what
should be followed
Description of what should never be done, or
what is prohibited
WARNING
Keep batteries out of reach of children. If
someone accidentally swallows a battery, call
a doctor immediately.
Do not put batteries in a fire, expose to heat,
disassemble or remodel. Doing so could case
fluid leakage, overheating or explosion.
Before disposing of batteries, wrap the termi-
nals with tape to insulate.
If a battery is allowed to come in contact with
other metal or batteries, it may cause heating,
destruction, and fire.
Wash off any calibration fluid that comes into
contact with hands or other exposed skin. If
fluid gets in eyes, rinse them immediately and
see a doctor.
CAUTION
Incorrect use of batteries may cause leakage
or bursting of the butteries and result in prod-
uct damage or burn injury.
• Connect the positive and negative terminals
of the battery correctly.
• Do not mix different battery types in the
same device.
• Replace all of the batteries in the same
device at the same time.
• Do not attempt to recharge batteries.
• Do not solder a battery.
• Store in a location away from direct sunlight,
high temperature, and high humidity.
Meter and sensor
The sensor is a consumable part.
If it becomes damaged or its per-
formance deteriorates, replace it
with a new one (the sensor can-
not be repaired).
Do not swing the meter and sen-
sor using a strap.
Do not drop the meter or apply
excessive force to it.
Do not leave the meter in areas of direct sun-
light or high temperature/humidity.
Do not clean the meter with organic solvents.
Neither the meter nor sensor is waterproof by
itself. The sensor must be securely mounted
on the meter before use.
To ensure the waterproof performance, confirm
the followings when attaching the sensor.
•The waterproofing gasket is clean and
undamaged.
•The waterproofing gasket is seated properly
in the groove with no twisting or warping.
•The meter and sensor are not deformed.
The flat sensor is made of thin material.
Take care not to break it.
If the sensor is dam-
aged, remove it from
the meter avoiding
injury and dispose of
it in a plastic bag.
Do not measure samples such as the follow-
ing, since they may damage the sensor or
shorten its life.
•Organic solvents
•Oils
•Adhesives
•Cement
•Alcohols
•Concentrated acid (0 to 2 pH)
•Concentrated alkaline (12 to 14 pH)
•Surfactants
If the sensor is damaged physically or chemi-
cally, stop using the sensor.
0.2 mm
For some samples (such as pure water), the
measured value may be unstable. This is natu-
ral.
A small amount of liquid or white powder may
appear on the liquid junction of the flat sensor.
The appearance of this powder or solution is
normal. Simply rinse it off with water before
use.
Battery
The batteries provided have been used for per-
formance testing. Therefore, their service life
may be short.
The battery alarm icon lights up when the bat-
tery voltage is low. Replace the batteries when
the battery alarm icon lights up. The meter
power may not be switched ON/OFF when the
battery voltage is low.
Identification of manufacturing date
Manufacturing date can be identified from MFG
No. described in the ID label on the backside of
the instrument.
Third number from the left in the MFG No. indi-
cates manufacturing year. Forth alphabet from
the left in the MFG No. indicates manufacturing
month. The alphabet is assigned to month
according to the table below.
Ex.: ID: AA6A0000 means the device manufac-
tured in 2016 January.
JAN FEB MAR APR MAY JUN
ABCDEF
JUL AUG SEP OCT NOV DEC
GH I JKL
For any questions regarding this product, please contact
your local agency, or inquire from the following website.
http://global.horiba.com/contact_e/index.htm
31, Miyanonishi-cho, Kisshoin Minami-ku, Kyoto,
601-8306, Japan
http://www.horiba-adt.jp

Other horiba Measuring Instrument manuals

horiba DO Tip 7541 User manual

horiba

horiba DO Tip 7541 User manual

horiba 9681S-10D User manual

horiba

horiba 9681S-10D User manual

horiba 9680S-10D User manual

horiba

horiba 9680S-10D User manual

horiba HR-200RT User manual

horiba

horiba HR-200RT User manual

horiba LAQUA COND DS-72 Installation guide

horiba

horiba LAQUA COND DS-72 Installation guide

horiba B-711 User manual

horiba

horiba B-711 User manual

horiba HU-200SS SS-90 User manual

horiba

horiba HU-200SS SS-90 User manual

horiba F-74BW User manual

horiba

horiba F-74BW User manual

horiba LAQUAtwin-Na-11 User manual

horiba

horiba LAQUAtwin-Na-11 User manual

horiba LaquaTwin B-771 User manual

horiba

horiba LaquaTwin B-771 User manual

horiba LAQUA-PH1500 User manual

horiba

horiba LAQUA-PH1500 User manual

horiba 9301-10D User manual

horiba

horiba 9301-10D User manual

horiba 6377-10d User manual

horiba

horiba 6377-10d User manual

horiba DS-51 User manual

horiba

horiba DS-51 User manual

horiba HP-100 User manual

horiba

horiba HP-100 User manual

horiba OPSA-150 User manual

horiba

horiba OPSA-150 User manual

horiba Phosphorimeter Trigger Installation and operating instructions

horiba

horiba Phosphorimeter Trigger Installation and operating instructions

horiba 9615S-10D User manual

horiba

horiba 9615S-10D User manual

horiba 9631-10D User manual

horiba

horiba 9631-10D User manual

horiba 9618-10D User manual

horiba

horiba 9618-10D User manual

horiba DS-71 User manual

horiba

horiba DS-71 User manual

horiba TPNA-500 User manual

horiba

horiba TPNA-500 User manual

horiba LAQUAact OM-71 Installation guide

horiba

horiba LAQUAact OM-71 Installation guide

horiba Fluorolog-3 User manual

horiba

horiba Fluorolog-3 User manual

Popular Measuring Instrument manuals by other brands

Neutronics QUICK DETECT Operation manual

Neutronics

Neutronics QUICK DETECT Operation manual

ATP Electronics MT-912 user manual

ATP Electronics

ATP Electronics MT-912 user manual

PCB Piezotronics 3743F1130G Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3743F1130G Installation and operating manual

Maxwell 25328 user manual

Maxwell

Maxwell 25328 user manual

Amphiro B1 Quick start user guide

Amphiro

Amphiro B1 Quick start user guide

Vanguard Instruments II Series operating instructions

Vanguard Instruments

Vanguard Instruments II Series operating instructions

Alluris FMI-S Series Operation manual

Alluris

Alluris FMI-S Series Operation manual

Renkforce RF-LP-500 operating instructions

Renkforce

Renkforce RF-LP-500 operating instructions

SICK MLG-2 Prime operating instructions

SICK

SICK MLG-2 Prime operating instructions

TFT HURRICANE XFIH-E2*A Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

TFT

TFT HURRICANE XFIH-E2*A Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Kramp KRED-D user guide

Kramp

Kramp KRED-D user guide

Data Translation DT9871 user manual

Data Translation

Data Translation DT9871 user manual

Kobold NBK-01 operating instructions

Kobold

Kobold NBK-01 operating instructions

ELCART 09/08550-00 Operation manual

ELCART

ELCART 09/08550-00 Operation manual

Sperry instruments DSA600TRMSR operating instructions

Sperry instruments

Sperry instruments DSA600TRMSR operating instructions

Fluke DSP-FOM Service Information Sheet

Fluke

Fluke DSP-FOM Service Information Sheet

Seikom Electronic RLSW 5A user manual

Seikom Electronic

Seikom Electronic RLSW 5A user manual

Teledyne Lecroy PP006C Operator's manual

Teledyne Lecroy

Teledyne Lecroy PP006C Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.