1
Important Information
• RFID Tag refers to the chip in any of the RFID “keys” included with the
RAPiD®Safe (RFID watchband tag, key fob or decals). You may also
purchase additional RFID tags.
• For trouble-free operation of your RAPiD®Safe, please read and
understand all instructions before use.
• Questions? Call our tech line at 800-338-3220.
• Never store loaded firearms in the RAPiD®Safe. Follow local laws for
firearm storage.
READ THIS FIRST
Warning: NEVER store a loaded firearm in the Hornady Security®
RAPiD®Safe Night Guard™under any circumstances. The risks associated
with storage of a loaded firearm include, but are not limited to, unintentional
discharge upon insertion or removal of the firearm. Unintentional discharge
may result in bullet and safe fragments dispersing in multiple directions,
which may cause serious injury or death. Hornady Security®is not liable for
any misuse of the RAPiD®Safe.
Warning: No safe is entirely secure. The RAPiD®Safe is only as secure
as your maintenance of the keys, code and RFID tags. You are solely
responsible for maintaining your keys, code and RFID tags. Keep your keys
and RFID tags in a secure location at all times. Store your RAPiD®Safe in a
secure location away from your keys and RFID tags. Hornady Security®
is not liable for unauthorized access, including damage to, or loss of
property, or personal injury. Again, NEVER store a loaded firearm in your
Hornady®RAPiD®Safe, as this may result in unauthorized access to the
loaded firearm.
Warning: Except as expressly provided in the RAPiD®Safe Limited
Warranty, Hornady Security®is not liable for any expense or damage
associated with your inability to open the RAPiD®Safe. Electronic systems
may fail. Verify that the keys furnished operate the lock. Keep your keys in a
secure location at all times. For your security, Hornady Security®WILL NOT
send replacement keys.
Warning: Hornady Security®is not liable for any loss, theft, or damage to
personal property. The RAPiD®Safe is not intended to protect the contents
from fire, water, humidity, or other environmental conditions. Do not, under
any circumstances, return the RAPiD®Safe to Hornady Security®with any
personal property inside.

2
Not Pictured:
• RAPiD®Safe Night Guard™
• Owner’s Manual
• Warranty Card
RAPiD®Safe Night Guard™
Item No: 98215
Exterior: 12"W x 10.5"D x 3"H
Interior: 9.2"W x 6.9"D x 2.2"H
Weight: 18 lbs.
Input Power: 12VDC 2.0A or
four (4) AAA batteries (not included)
Output Power: 5VDC 2.0A
Table of Contents
Warnings and Important Information............................................... Page 1
Items Included...................................................................................... Page 2
Setup and Operation ........................................................................... Page 3
Securing Your Safe.............................................................................. Page 9
Product Registration and Service .................................................... Page 10
Warranty................................................................................................ Page 10
Frequently Asked Questions ............................................................. Page 11
Items included with your RAPiD®Safe
1. RAPiD®Safe Night Guard™
2. Wall Power Supply
3. One (1) RFID Watchband Tag (No. 95159)
4. Two (2) RFID Adhesive Decals (No. 98168)
5. One (1) RFID Key Fob Tag (No. 98167)
6. Two (2) Circular Barrel Keys
7. Security Cable (No. 98169)
2
4
5
6
3
7
U.S. Patent No. 9,530,266
U.S. Patent No. 10,233,687
U.S. Design Patent No. D786,047

3
RAPiD®Safe Setup and Operation
Congratulations on purchasing the technologically advanced RAPiD®Safe
Night Guard.
™
You have taken a significant step in securing the safety of
your firearms.
To achieve the best experience with your RAPiD®Safe, please read all
instructions carefully, and understand its operation.
After the RAPiD®Safe has been taken out of the box, please check to be
sure both circular barrel keys fit and unlock your RAPiD®Safe. Contact
Hornady®at 800-338-3220 if the keys do not work. Store keys in a secure
location outside the safe.
Open Safe with Key
The RAPiD®Safe includes
two barrel keys that will open
the safe when inserted into
the lock on the back panel of
the RAPiD®Safe and turned
clockwise.
NOTE: Store keys in a secure
location outside of the safe.
AC Power
The RAPiD®Safe is designed to be powered by either the AC power supply
or four AAA batteries.
To connect the AC power supply, plug the power cord into the jack on the
back of the safe.
Keypad Tones On/Off
With the door open and unlocked, press and hold the “H” button on the
keypad for 5 seconds until the light turns off to toggle sound on and off.
Key Lock
Power Jack

4
Battery Power Mode
When the RAPiD®Safe is unplugged, and is operating on battery power,
you must press any button on the keypad to activate the reader.
Pressing any button on the keypad causes the system to go from battery
saving mode to ready status.
For example: To open your safe with an RFID tag, while the system is
running on battery power, first press any button on the keypad to bring it
to ready status. Place your RFID tag within 1" of the center of the clock
display to open the safe.
RFID Reader Area“H” Button & Key Pad
Batteries
To install batteries, press the lower
left corner of the battery cover on the
front of the safe. Insert four (4) high
quality AAA batteries according to
the diagram. Replace all batteries at
the same time.
NOTE: The battery symbol near the
clock display will illuminate red when
the batteries are weak. Plug in the
safe or replace batteries immediately.
Press Here to Open
Low battery indicator

5
How to Program Your RFID Tags
Your RAPiD®Safe includes three (3) styles of RFID tags, including:
• 1 Watchband Tag
• 1 Key Fob
• 2 Decals
*Additional styles can be purchased separately.
The RAPiD®Safe can store up to five tags.
To program these tags:
1. Open the RAPiD Safe with either
the key or a previously programmed
RFID tag or key code. The safe
does not ship with pre-programmed
RFID tags. A RFID tag must be
programmed to work with this safe.
2. Locate the red program button
inside the drawer on the back
wall. Press and release the button
to begin programming a RFID tag.
The first available program
location will begin to blink.
3. Hold the RFID tag within 1" of the
illuminated RFID reader area (clock display) on the drawer front If the
programming was successful, the safe should beep two times and the
available slot should go from blinking to solid red for approximately ten
seconds.
NOTE: If the user attempts to program a RFID tag that is already
stored in the safe it will beep three times and the RFID tag will not
be programmed into the duplicate slot. The RFID tag can only be
programmed into one location.
4. Verify the RFID tag is programmed by holding the tag over the clock
display with the drawer open. The motor should cycle after each scan.
5. If the RFID tag is not programmed, the program function will time out
after ten seconds and the safe will return to normal operation.
If multiple attempts to program a RFID tag fails, please contact
Hornady®at 800-338-3220.
6. One to five RFID tags can be programmed into the safe.
Program Button

6
NOTE: Due to potential interference from
the body (attenuation), the RFID watchband
tag should be worn on the outside or
bottom of the wrist and may need to be
brought within 1-inch of the reader to
activate the safe. The RFID reader will likely
not read through the wrist.
NOTE: The RFID decal can be placed
on a variety of objects. However, metal
surfaces may cause interference
and reduce the read distance. The
integrated metal housing on some
cell phones combined with potential
interference from other wireless
signals such as Bluetooth, NFC, etc.,
may reduce the read distance of the
RFID decal.
Before adhering the RFID decal to a
mobile phone, we recommend trying
different locations on the back of
the device to find the optimum read
distance. Placing the decal on the
RFID Decal Decal in Use
outside of an accessory cover will
also improve the read distance, but
may cause excessive wear, resulting
in a shortened life of the decal. When
placing the decal on the inside of
an accessory cover, DO NOT face it
toward the mobile phone. The decal
must face outward (away from the
phone) to work optimally.
Before placing the RAPiD Safe
into service, verify the decal works
properly under various conditions
(i.e. the wireless apps on your mobile
phone are on).
RFID Watchband
Tag

7
How to Remove All Tags From Safe
1. Open the RAPiD®Safe with either the key, a previously programmed
RFID tag, or key code. Locate the red program button. Press and hold
the button for five seconds to erase all previously programmed tags.
All five red LEDs will begin to blink in sequence. The safe does not allow
individual tags to be removed. They must all be erased at one time.
The intended RFID tags can then be reprogrammed with the “How to
Program Your RFID Tags” section.
NOTE: To abort the erase procedure, press the “H” button on the
drawer of the safe or do not touch anything and the erase procedure
will automatically abort after 10 seconds and return to normal operation.
Test RFID tags and the key code to confirm they are operational.
2. To confirm erasing procedure, press and release the program button
again. All five LEDs will blink three times to visually confirm all RFID tags
have been removed. The RFID tags will no longer work until they are
reprogrammed with the instructions in the “How to Program Your RFID
Tags” section.
How to Program Your Key Code
A single user-defined 4 to 6 digit code can be entered into the
RAPiD®Safe Night Guard.
™
1. Open the RAPiD Safe with either the key, a previously programmed
RFID tag, or key code. The safe ships with a default code and should
be reprogrammed before first use.
2. Locate the red program button to begin programming your key code.
The first available tag location will begin to blink to indicate
program mode.
3. With the drawer open, enter a 4 to 6 digit code on the keypad. Press the
“H” after entering your code. Verify your code is correct by re-entering
your code and pressing “H”. The motor should cycle.
4. Your key code can now be used to open the safe.
NOTE: Only one key code can be entered into the safe. If a second
code is entered, it will override the previous code. **A total of five RFID
tags and one key code can be entered into the safe.

8
Closing the Night Guard
The safe has a latch closure sensor that will illuminate the LED in the
keypad when the drawer is closed.
Green – Latch has fully closed.
Blinking Red – Latch has NOT fully closed.
To close the safe, press the drawer in until the latch clicks. Verify green
light appears on the keypad.
USB Charging Ports
The RAPiD®Safe includes two
USB Type A charging ports on the
back of the safe.
When the RAPiD®Safe is plugged
into AC power with the included
power supply, the two charging
ports can be used to power
common electronics.
Total Output: 5VDC 2.0A
How to Program Clock
To program the clock display, press and hold the TIME button until the
hour digit begins to blink (approximately 5 seconds). Press the UP or
DOWN arrow buttons to adjust the hour.
Press the TIME button again to switch to minutes and adjust with the
UP and DOWN arrow buttons. Pressing the TIME button again will finish
setting the time.
To adjust the brightness of the clock display, press the UP and DOWN
arrow buttons until the desired brightness is reached.
The clock display can be turned off by pressing the DOWN arrow button
until the clock display is off.
USB Ports
Power Jack

9
Securing Your Safe
To maintain the security of the
safe either use the included
security cable or bolt the safe to
a secure structure.
Using the Security Cable
Wrap the security cable around
a secure object and place the
ferrule end through the loop in
the cable. With the drawer open,
snap the narrowest diameter
of the ferrule into the back of
the safe by gently pushing the
ferrule end against the spring plate
and sliding the ferrule down. As the
drawer closes, it presses against
the spring plate and locks the
ferrule in place.
To remove the security cable, open
the safe and press the pin above
the ferrule while lifting the ferrule.
Bolting Down the Safe
Remove the drawer by gently
pulling it out while pressing the
plastic tab on the left side up and
the tab on the right side down. Note
the small electrical wire that runs
from the back of the safe to the
back of the drawer.
CAUTION: Do not pull or pinch the
cable as it may damage the wiring.
Mark and pre-drill holes before
installing the appropriate fasteners
for your application.
Reinstall the drawer by aligning the drawer slides with the slides on the
housing. Before pushing the drawer into the housing, verify that the electrical
wire connection is safely inside the housing and will not be pinched as the
drawer is closed.
Plastic Tab
Ferrule locked
in place
Narrowest Diameter
of Ferrule
Pin
Spring Plate

10
RAPiD®Safe Limited Warranty
Hornady Security®warrants the RAPiD®Safe will, in normal use and service, be free from
defects in workmanship or materials for one (1) year from date of purchase.
This Limited Warranty does not cover any of the following:
(a) Damage, deterioration, or malfunction resulting from accident, negligence, misuse,
improper installation, or lack of maintenance;
(b) Any defects not discovered and reported to Hornady Security®during the one (1)
year warranty period;
(c) Usual and customary deterioration or wear resulting from normal use.
This Limited Warranty is not transferable and is enforceable by the original owner only. In the
event that Hornady Security®receives notice from the original purchase of a warranty claim in
conformity herewith, Hornady Security®will promptly undertake an investigation of such claim.
If the warranty claim is covered by the Limited Warranty, Hornady Security®
will, in its sole
discretion, repair the defect(s) or replace RAPiD®Safe at the expense of Hornady Security.
®
Disclaimer of Implied Warranties. EXCEPT AS IS OTHERWISE EXPRESSLY SET FORTH IN THE ABOVE
LIMITED WARRANTY, HORNADY SECURITY®MAKES NO OTHER REPRESENTATIONS OR WARRANTIES
OF ANY KIND, WHETHER EXPRESSED OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE WITH
RESPECT TO THE RAPiD®SAFE OR ANY COMPONENT PART THEREOF, INCLUDING WITHOUT LIMITATION
ANY REPRESENTATION OR WARRANTY WITH RESPECT TO MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE OR USE.
Limitation on Liability. THE OBLIGATION OF HORNADY SECURITY®TO REPAIR OR REPLACE AS
PROVIDED ABOVE SHALL BE THE SOLE AND ONLY REMEDY RESPECTING ANY DEFECT IN THE RAPiD®
SAFE, OR ANY COMPONENT PART THEREOF. IN THE EVENT THAT THE FOREGOING REMEDY FAILS OF
ITS ESSENTIAL PURPOSE, THE LIABILITY OF HORNADY SECURITY®TO PURCHASER SHALL NOT, IN ANY
EVENT, EXCEED THE ACTUAL PURCHASE PRICE OF THE NON-CONFORMING GOODS; AND
Limitation on the Nature of Damages. HORNADY SECURITY®SHALL NOT, UNDER ANY
CIRCUMSTANCES, BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, CONSEQUENTIAL, LIQUIDATED OR PUNITIVE DAMAGES OF ANY NAME, NATURE OR
DESCRIPTION. HORNADY SECURITY®IS NOT RESPONSIBLE FOR DAMAGE TO OR THEFT OF
THE RAPiD®SAFE, OR ITS CONTENTS.
Product Registration and Service
You must register your RAPiD®Safe Night Guard™in order to obtain Warranty
Service. Simply complete and return the enclosed product registration card or
submit through our website by going to hornady.com/warranties.
To Receive Warranty Service
In order to report a warranty claim, call Hornady Security®at 800-338-3220 to
request a return authorization number. Returns will not be accepted without prior
return authorization by Hornady Security.®When a return authorization number
has been obtained, be sure all contents have been removed from the RAPiD®
Safe before sending it for service. Hornady Security®is not liable for any loss,
theft, or damage to personal property.
Post-Warranty Service Information
For issues concerning service after the Limited Warranty expires, contact
Hornady Security®at 800-338-3220.

19HMC0119 | 07/2020
P.O. Box 1848, Grand Island, Nebraska 68802-1848
308-382-1390 • 800-338-3220 • Fax: 308-382-5761 • Hornady.com/contact
586002
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Changes or modications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Frequently Asked Questions
I’ve lost my keys. Can I get a replacement?
Contact Hornady Security®at 800-338-3220 and one of our technicians
will assist you.
Where can I find the serial number?
The serial number is located on the back of the safe. Prior to mounting
the safe, record the serial number for future reference.
How long should the batteries last?
Quality batteries should last approximately 12 months, depending on use.
How do I return my RAPiD® Safe for warranty work?
Call Hornady®at 800-338-3220 and one of our technicians will assist you.
Why isn’t my RFID watchband tag, key fob, or decals opening the safe?
• Be sure the RFID tag is programmed to your safe. The RAPiD®Safe
allows five (5) RFID tags to be programmed for use.
• Check the power source. If the unit is plugged into an electrical outlet,
the green LED light should be on. If the unit is on battery power, press the
button on the top of the safe to bring the system to ready before placing
the RFID tag on the reader.