ENGLISH
5
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
* The connections to the mains water supply
must be made in accordance with the countries’
current requirements of the Water Supply or
Water Fittings Regulations.
* Icemaking water must be potable water.
Where scaling can be caused by water quality,
installation of an external filter or softener
is recommended. Contact your local water
treatment professional or Hoshizaki service
agent.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
* The icemaker drain is gravity flow, so ensure
drain hose has an adequate pitch or fall.
* Drain lines should not
be installed directly
to the sewer system.
A vertical air gap of a
minimum of 5 cm should
be between the end of
the drain hoses from the
icemaker and storage
bin and the oor drain.
* Be sure to use the new hose-sets supplied with
the appliance. Do not reuse any old hose-sets.
1) Attach the angled end of flexible inlet hose
(accessory) to the G3/4 tting on the rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
suciently to provide leak free joint.
2) Attach the other end of inlet hose to the water
tap, noting washer is correctly positioned before
hand tightening as above. It is a wise precaution
to have a stop valve within easy reach.
3) Hand tighten grey exible outlet hose (accessory)
onto the R3/4 tting on the rear of the icemaker
as indicated, ensuring rubber washer is correctly
positioned to obtain a leak free joint. The hose
can be cut to length as necessary to suit position
of main drain.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the symbol
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected
to the terminal which is marked with the letter N
or coloured Black. The wire which is coloured
Brown must be connected to the terminal which
is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut o if it is
moulded on plug) and an appropriate plug tted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being tted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer’s
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to
BS 1362.
5. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable cold water supply only.
5cm air gap
Drain
Floor
Fig. 10