HTW WAVE HTW-VE-035V1 Service manual

OWNER’S AND INSTALLATION
MANUAL
MOBILE HOME AIR CONDITIONER
WAVE
HTW-VE-035V1
Thanks for choossing our product.
Please, read carefully this manual
before using the product
ENGLISH

CONTENTS
A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT .......................................1
ELECTRICAL DATA ..............................................................................................................1
OPERATION OF WIRELESS REMOTE CONTROLLER ......................................................6
CONTROL PANEL ..............................................................................................................13
CONTROL PANEL(WIFI).....................................................................................................14
NORMAL MAINTENANCE PROCEDURES .......................................................................23
ELECTRIC DIAGRAM ...........................................................................................................2
ELECTRIC DIAGRAM(WIFI) .................................................................................................3
INSTALLATION INSTRUCTION..........................................................................................15
STEP 4-ELECTRICAL WIRING ..................................................................................................20
STEP 5-COMPLETING THE INSTALLATION .................................................................................21
STEP 3-INSTALLING THE CEILING ASSEMBLY .............................................................................19
STEP 2-MOUNTING OUTDOOR UNIT..........................................................................................18
STEP 1-SELECTING AN INSTALLATION LOCATION & INSTALLING THE ROOF TOP AIR CONDITIONER
......15
TROUBLESHOOTING GUIDE ............................................................................................22
PACKING LIST ......................................................................................................................4
PARTS NAME........................................................................................................................5
●
●
●
●
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
This appliance can be used by children aged from 8 years and above and persons
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.

INSTALLATION PRECAUTION
WARNING:
● Observe all governing codes and ordinances.
● Do not use damaged or non-standard power cord.
● Be caution during installation and maintenance. Prohibit inco
Suggested working temperature range: +4 ~ 46℃. Outdoor unit may stop operation
rrect operation
to prevent electric shock, casualty and other accidents.
due to various kinds of protection within working temperature range.
Selection of Installation Location
Working temperature range
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable,
please consult the local dealer:
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
Requirement of air conditioner
1. Air inlet should be far away from obstacles and do not put any objects near air
outlet. Otherwise, it will affect the radiation of heat-removal pipe.
not affect neighborood.
4.The appliance shall not be installed in the laundry.
Requirements Forelectric Connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
3. For appliances with type Y attachment,the instructions shall contain the
substance of the following.If the supply cord is damaged,it must be replaced by
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
. Be sure to cut off the power supply before proceeding any work related to electricity and safety.5
with specialized grounding device by a professional. Please make sure it is
always grounded effectively, otherwise it may cause electric shock.
8. The yellow-green wire or green wire in air conditioner is grounding wire, which
can't be used for other purposes.
9. The grounding resistance should comply with national electric safety regulations.
10. The appliance shall be installed in accordance with national wiring regulations
avoid a hazard.

A FEW WORDS ABOUT YOUR NEW
AIR CONDITIONING UNIT
ELECTRICAL
DATA
1.All wiring must be complied with local and national electrical codes. All wiring
must be installed by qualified electricians. If you have
any questions about the
following instructions, contact a qualified
electrician.
2.
Check the available power supply and resolve any wiring problems BEFORE installing
and operating this unit.
3.
This air conditioner is designed to operate from a 220-240V AC, 50Hz, 1 Phase
power supply.
4.
The wiring diagrams are located on the cover of the control box. The assembly unit
wire diagrams are located on the ceiling panel.
- 1 -
Thank you for choosing the Recreational Vehicle Air Conditioner.
This manual will supply you with all the information for installation, operation and maintenance.
Take a few minutes to discover how to get the most in cooling comfort and economic operation
from your new air conditioner.
Please keep this manual well for future reference.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should
be connected in fixed wiring.

Ceiling Assembly
ELECTRIC DIAGRAM
Roof Top Air Conditioner
- 2-
Notice: Use Copper Conductors Only.
M1
STEPPING
MOTOR
M2
STEPPING
MOTOR
AP2
LED
BOARD
OUTDOOR UNIT
RT1
ROOM
SENSOR
AP1
DISPLAY
DISP1
SW1 SW2 CN1
DISP2
DISP3
BOARD
YEGN(GN)
BU(WH)
BN
L
N
POWER
PE
L
N
BU
YEGN
BN(BK)
TERMINAL
BLOCK
CAP. WH
BU
BU
R
S
INDOOR UNIT
OUTROOM
SENSOR
YAW4 N
VALVE
4-WAY
4YV
MOTOR
DISP1
N1 COMP
PE
OUT_FAN
AC-L1
PE
BU
BN
YEGN
DISP2 AP1
YEGN
PE
ELECTRIC BOX
PE
YEGN
M3
PE
YEGN
OUT_FAN1
MOTOR
IN_FAN
PE
YEGN
IN_FAN
M1
OUTDOOR
TUBE SENSOR
CN5
RT1
TUBE
SENSOR
RT2
CN4
OUT_FAN
MAIN BOARD
RT3
M2
(20K) (15K)(20K)
(WH) (BK)
VT VT
K1
MOTOR
OUT_FAN
C
RD
COMP YEGN
PE
COMP.

ELECTRIC DIAGRAM
GRH085DA-K3NA1A(WIFI)
Roof Top Air Conditioner
- 3 -
Notice: Use Copper Conductors Only.
Ceiling Assembly
M1
STEPPING
MOTOR
M2
STEPPING
MOTOR
AP2
LED
BOARD
OUTDOOR UNIT
RT1
ROOM
SENSOR
AP1
DISPLAY
DISP1
SW1 SW2 CN1
DISP2
DISP3
BOARD
YEGN(GN)
BU(WH)
BN
L
N
POWER
PE
L
N
BU
YEGN
BN(BK)
TERMINAL
BLOCK
CONNECTOR
AP3
WIFI
MODULE
(WIFI)
CAP. WH
BU
S
BU
R
INDOOR UNIT
OUTROOM
SENSOR
N4WAY
VALVE
4-WAY
4YV
MOTOR
DISP1
N1 COMP
PE
OUT_FAN
AC-L1
PE
BU
BN
YEGN
DISP2 AP1
YEGN
PE
ELECTRIC BOX
PE
YEGN
M3
PE
YEGN
OUT_FAN1
MOTOR
IN_FAN
PE
YEGN
IN_FAN
M1
OUTDOOR
TUBE SENSOR
CN5
RT1
TUBE
SENSOR
RT2
CN4
OUT_FAN
MAIN BOARD
RT3
M2
(20K) (15K)(20K)
(WH) (BK)
VT VT
K1
MOTOR
OUT_FAN
WIFI_CON
C
RD
COMP YEGN
PE
COMP.
GRH120DA-K3NA1A

- 4 -
PACKING LIST
Packi ng List of Outdoor Unit
Packi ng List of Indoor Unit
Bolt su b-assy sp onge (air duct ) Remote co ntroller holder
Plate of air ve nt Double-si ded gummed paper
M8X135 (4)
Tapping scr ew
ST4.2X9.5 TA (8) Scr ew ca p (6) Sunk scr ew (2)
(remote co ntroller holder)
battery (2)
use in indoor
(bottom) (upper)
use in outdoor
(AAA 1.5V)
remote co ntroller
LED
TIMER ON
LIGHT
owner’s manual
power su pply ci rcu it
cl a sp (10)

PARTS NAME
LED indica tor
Air-in grille
Air-outgrille
Filter su b-assy
Outer ca se
Chassi s
Air-in grille
Drainage outlet
Control panel (membrane)
(Display content or position may be different from above
graphics, please refer to actual products)
Indoor Unit
Outdoor Unit
remote controller
Actual product may be different from above graphics, please refer to actual
products.
NOTICE:
- 5-
LED
TIMER ON
LIGHT

OPERATION OF WIRELESS REMOTE CONTROLLER
Buttons on remote controller
Introduction for icons on display screen
- 6-
Note: This remote co ntroller is the unive rsa l remote co ntroller. Some funct ion is not
ava ilable for this unit.
1
2
3
4
5
6
7
8
9
10
11
12
ON/OFF button
MODE button
- button
+ button
FAN button
LED button
TIMER ON button
TEMP button
TIMER OFF button
TURBO button
13 SLEEP button
14 LIGHT button
CLOCK button
button
1
3
5
7
9
12
2
4
6
8
11
10
14
13
Turbo mode
Send signal
Set temperature
Set time
TIMER ON /
TIMER OFF
Child lock
Up & down swing
Set fan speed
Light
Temp. display type
:Set temp.
:Outdoor ambient temp. :Indoor ambient temp.
Sleep mode
Clock
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
LED
TIMER ON
LIGHT
This is a general remote co ntroller. Some
models have this funct ion while so me do
not. Please refer to the act ual models.

- 7-
ON/OFF button
1
Press this button, the unit will be turned on, press it once more, the unit will be turned
off. When turning on or turning off the unit, the Timer, Sleep function will be canceled,
but the presetting time is still remained.
MODE button
2
Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto mode
- button
3
Presetting temperature can be decreased. Press this button, the temperature can be set up,
+ button
4
For presetting temperature increasing. Press this button, can set up the temperature, when
unit is on. Continuously press and hold this button for more than 2 seconds, the corresponding
contents will be changed rapidly, until unpress the button then send the information,
℃
(
℉
)
is displlaying all along. In Auto mode, the temperature can not be set up, but operate this button
can send the signal. Centigrade setting range: 16-30; Fahrenheit scale setting range 61-86.
continuously press this button and hold for two seconds, the relative contents can quickly
change, until unhold this button and send the order that the
℃
(
℉
) signal will be displayed
all the time. The temperature adjustment is unavailable under the Auto mode, but the order
can be sent by if pressing this button.
is default while power on. Under Auto mode, the temperature will not be displayed;
Under Heat mode, the initial value is 28
℃
(82
℉
); Under other modes, the initial value is
25
℃
(77
℉
).
AUTO COOL DRY FAN HEAT
(Only for cooling and heating unit. As for cooling only unit, it won’t have any action when it receives the signal of heating
operation.)
● This is a general use remote controller, it could be used for the air conditioners with multifunction; For
some function, which the model doesn't have, if press the corresponding button on the remote controller
that the unit will keep the original running status.
● After putting through power, air conditioner will give out a sound and operation indicator
" "
is ON
(red indicator). You can operate the air conditioner through the remote controller.
●
At ON status, after each pressing button on remote controller, the signal icon " "
on remote controller will
flash once.Air conditioner will give out a sound,which
indicates the signal has been sent to air conditioner.
● nder off status, set temperature and clock icon will be displayed on the display of remote controller
(If timer on, timer off and light functions are set, the corre-sponding icons will be displayed on the display of
remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
Introduction for buttons on remote controller
Note:

- 8-
FAN button
5
Press this button, Auto, Low, Middle, High speed can be circularly selected. After powered
6
Other air conditioners, press this button, to set up swing angle, which circularly
Press this button turn on swing function; 4s later, press this button to turn off the swing
and it will operate like that circularly.
changes as below:
This is an universal use remote controller. If remote controller sends the following three
kinds of status that the swing status of main unit will be:
When the guide louver start to swing up and down, if turn off the Swing, the air guide
louver will stop at current position.
which indicates the guide louver swings up and down between that all five positions.
on, Auto fan is not available for this mode. When pressing AUTO button, the fan speed
will not change.
Note: Under the Dry mode, the fan speed isn't adjustable, low fan speed is imperative,
but when operating this button, the wireless adjustable, low fan speed is imperative.
button
7
Press this button, the clock can be set up, signal blink and display. Within 5 seconds,
the value can be adjusted by pressing + or - button, if continuously press this button for
2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased
1. During blinking, repress the Clock button, signal will be constantly displayed and it
denotes the setting succeeded. After powered on,12:00 is defaulted to display and signal
is Clock value, otherwise is Timer value.
will be displayed. If there is signal be displayed that denotes the current time value
Middle fanLow fan
AUTO
High fan
OFF
CLOCK button
8
Press this button can turn on or turn off the LED light on the panel.
LED button
9
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical
section will become the timer on setting status. During 5 seconds blink, by pressing + or
will be increased or decreased 1 minute. Hold pressing + or - button, 2 seconds later, it
- button to adjust the time value of numerical section, every press of that button, the value
TIMER ON button

- 9 -
TEMP button
10
Press this button, could select displaying the indoor setting temperature or indoor
TIMER OFF button
11
Once press this key to enter into TIMER OFF setup, in which case the TIMER OFF
TURBO button
12
In Cool or Heat mode, press this button can turn on or turn off the Turbo function.
SLEEP button
13
Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep
Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep
function set up, the signal of Sleep will display.In this mode, the time of timer can be
adjusted. Under Fan and Auto modes, this function is not available.
After turned on the Turbo function, its signal will be displayed. When switching the
mode or changing fan speed, this function will be canceled automatically.
icon will blink.
The method of setting is the same as for TIMER ON.
ambient temperature. When the indoor unit firstly power on it will display the setting
temperature, if the temperature's displaying status is changed from other status to
control signal that will return to display the setting temperature. if the users haven't
set up the temperature displaying status, that will display the setting temperature.
(This function is applicable to partial of models)
After powered on, the setting temperature displaying is defaulted, (according to cust-
omers requirements to display, if there is no requirement that will default to display
Press this button, (When displaying ), will display presetting temperature; (when
displaying ) will display indoor ambient temperature, current displaying status
will not be changed. If current displays indoor ambient temperature, if received the
other remote control signal, it will display presetting temperature, 5s later, will back
to display the ambient temperature.
(This function is applicable to partial ofmodels)
the presetting temperature and there is no icon displayed on wireless remote control).
" ", displays the ambient temperature, 5s later or within 5s, it receives other remote
button, the timer setting succeeds. The Timer On has been set up, repress the timer On
button, the Timer On will be canceled. Before setting the Timer, please adjust the Clock
to the current actual time.
in the one place of minute, then the one place is constant, ten numbers change in the
tens place of minute at 2.5 seconds speed and carry. During 5s blink, press the Timer
quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change

- 10-
Introduction for special function
14
Press this button to select LIGHT on or off in the displayer. When the LIGHT on is set,
the icon will be displayed and the indicator light in the displayer will be on. When the
LIGHT off is set, the icon will be displayed and the indicator light in the displayer will
be off.
LIGHT button
About AUTO RUN
When AUTO RUN mode is selected, the setting temperature will not be displayed on
About turbo function
WIFI Function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so
About Blow over heat
(This function is applicable to partial of models)
When the unit is running in Heat mode or Auto Heat mode, compressor and indoor fan
is running, to turn the unit off, the compressor, outdoor fan will stop running. The upper
and lower guide board rotate to horizontal position, then the indoor fan will run at low
fan speed, 10s later, the unit will turn off.
that the ambient temp. approachs the preset temp. as soon as possible.
the LCD, the unit will be in accordance with the room temp. automatically to select the
suitable running method and to make ambient comfortable.
Press "MODE" and "TURBO" button simultaneously to turn on or turn off WIFI
function. When WIFI function is turned on, the " " icon will be displayed on
remote controller; Long press "MODE" and "TURBO" buttons simultaneously for
10s, remote controller will send WIFI reset code and then the WIFI function will be
turned on. WIFI function is defaulted ON after energization of the remote controller.
(This function only applicable for some models. )

LED
TIMER ON
LED
TIMER ON
LIGHT
- 11-
General operation
1. After powered on, press ON/OFF button, the unit will
Optional operation
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set
3. Press LIGHT button, to control the on and off of the
4. Press TURBO button, can realize the ON and OFF
5. Press LED button,can open or close the light on the panel.
start to run. (Note: when it is powered on, the guide
2. Press MODE button, select desired running mode.
3. Pressing + or - button,to set the desired temperature.
4. Pressing FAN button, set fan speed, can select
5. Pressing button, to select the swing.
louver of main unit will close automatically.)
(It isunnecessary to set the temp. at AUTO mode.)
LOW, MID and HIGH.
the scheduled timer on or timer off.
displaying part of the unit (This function may be not
available for some units).
of TURBO function.
Operation guide
LIGHT

-12-
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
battery
Cover of battery box
remove
reinstall
●ntrol signal sender at the receiving
window on indoor unit.
●The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
or wireless telephone; remote controller should be close to indoor unit during
operation.
●equired.
●take out the
batteries.
●s no display, please
replace batteries.
NOTICE
Replacement of batteries in remote controller

CONTROL PANEL
Note: If the remote controller is missing, operate on the control panel.
1ON/OFF button
Operation starts when pressing this button, and
stops when pressing this button again.
2SWING button
Activate the automatic air swing function.
3FAN SPEED button
Select the fan speed LOW, MED, HIGH and TURBO
in sequence.
6FILTER CHECK button
This feature is a reminder of cleaning the air
filter(normal maintenance) for more efficient
operation. The light will turn on automatically
after the fan works more than 250 hours.
If the light is on, turn off and power off the
unit, take the air filter out and clean it, then
re-install the air filter, power on and turn
on the unit, the light will still be on, press
FILTER CHECK button,the light will
turn off.
4(+/-) / TIMER button
Press the + button to increase the set(operating)
temperature of the unit,and press the - button to
decrease the set(operating) temperature of the
unit. the temperature setting range is from 16~30℃
Press TIMER button,then press +/- to increase
and decrease the time setting.If the time setting
is no more than 10 hours,the increment/decrement
is 0.5 hour by each press,if more than 10 hours,
the increment/decrement is 1 hour by each press.
The time setting range is 0.5~24 hours.
o
(61~86 F).
- 13-
5MODE button
Select the operation mode, COOL, DRY,
FAN, HEAT (for heat pump model) or
COOL, DRY, FAN (for cooling only model).
3 46
21
4
5
Not available for
cooling only model
TURBO
HIGH
MED
LOW

CONTROL PANEL
GRH085DA-K3NA1A(WIFI)
Note: If the remote controller is missing, operate on the control panel.
Not available for
cooling only model
1ON/OFF button
Operation starts when pressing this button, and
stops when pressing this button again.
2SWING button
Activate the automatic air swing function.
3FAN SPEED button
Select the fan speed LOW, MED, HIGH and TURBO
in sequence.
6FILTER CHECK button
This feature is a reminder of cleaning the air
filter(normal maintenance) for more efficient
operation. The light will turn on automatically
after the fan works more than 250 hours.
If the light is on, turn off and power off the
unit, take the air filter out and clean it, then
re-install the air filter, power on and turn
on the unit, the light will still be on, press
FILTER CHECK button,the light will
turn off.
4(+/-) / WIFI button
Press the + button to increase the set(operating)
temperature of the unit,and press the - button to
decrease the set(operating) temperature of the
unit. the temperature setting range is from 16~30℃
Press WIFI button to turn on or turn off WIFI
function. When WIFI function is turned on, the
wifi light will be displayed. (The function only
applicable for some models. )
o
(61~86 F).
- 14-
5MODE button
Select the operation mode, COOL, DRY,
FAN, HEAT (for heat pump model) or
COOL, DRY, FAN (for cooling only model).
TURBO
HIGH
MED
LOW
WIFI
21
346 5
4
GRH120DA-K3NA1A (WIFI)

INSTALLATION INSTRUCTION
BEFORE INSTALLATION
T
estrun the unit with proper power supply. Refer to the
operation instruction section in the Owner’s Manual
Operation & Installation. Make sure all the controls
operate correctly then disconnect the power supply
of the unit.
WARNING
!
Moving parts may cause personal injury. Be careful when test the unit. Do not operate the unit
with exterior cover removed.
STEP 1-SELECTING AN INSTALLATION LOCATION &
INSTALLING THE ROOF TOPAIR CONDITIONER
Your air conditioner has been designed for use in recreational vehicles.
Check the roof of the vehicle to determine if it can support both the roof top unit and the ceiling
assembly without additional support. Make sure the interior ceiling mounting area will not
interfere with existing structures.
Once the location for your air conditioner has been determined. A reinforced and framed roof
hole opening must be cut (if there is no hole) or you may use existing vent holes.
CASE A.
If a roof vent is already present in the desired mounting location for the air conditioner, the
following steps must be performed:
1.
Remove all screws which secure the roof vent to the vehicle. Remove the vent and any
additional trim. Carefully remove all chalking from around the opening so the surface is
clear.
2.
It may be necessary to seal some of the old roof vent mounting screw holes which may
fall outside of the air conditioner basepan gasket.
3.
Examine the roof opening size, if the opening is small than 356x356mm, the opening
must be enlarged. If the opening exceeds 356x356mm, a mounting plate (frame) must
be fabricated to reduce the opening size (See Figure 1).
- 15-
● Before installation, please check whether the unit is assembled
with three pieces of rubber pads and square sealing strip.

356
356
19
25
Figure 1
If a roof vent opening is not used,a new opening(see figure 1)will be cut into the vehicl roof.
A matching opening will also have to be cut into the interior vehicle ceiling,be careful when
cutting the ceiling opening because if the ceiling opening is carpeted,snagging could occur. After
the opening in the roof and interior ceiling are the correct size,a framed support structure must
be placed between the exterior roof top and interior ceiling.The reinforced framed structure must
follow the follwing guidelines: 1. It must be capable of supporting both the
weight of the roof top air conditioner and
the interior ceiling assembly.
3.
There must be an opening through the
frame for the power supply wiring.Route
the supply wiring through the frame at the
same time the support frame is being
installed.
2.
It must be capable of holding the roof outer
surface and interior ceiling apart and
supporting them, so that when the roof top
air conditioner and ceiling assembly are
bolted together,no collapsing occurs. A
typical support frame is shown in Figure 1.
CAUTION
1.The roof top air conditioner must be mounted on a level plane from front to rear and side to
side when the vehicle is parked on a level plane. Figure 2shows maximum allowable degrees
that the unit can be mounted above or below level.
2.If the roof of the vehicle is sloped (not level) such that the roof top air conditioner cannot be
mounted within the maximum allowable degree specifications, an exterior leveling shim will
need to be added to make the unit level. A typical leveling shim is shown in Figure 3.
3.
Once the roof top air conditioner has been leveled, some additional shimming may be required
above the interior ceiling assembly. The roof top air conditioner and the interior ceiling assembly
must be square with each other before they are secured together.
4.After the mounting hole area is properly prepared, remove the carton and shipping pads from
around the roof top air conditioner. Carefully lift the unit on top of the vehicle. Do not use the outer
plastic shroud for lifting. Place the roof top air conditioner over the prepared mounting hole.
5.The point end (nose) of the shroud must face toward the front of the vehicle.
Hole for
Wires
CASE B.
- 16-

356
356
NOTE AIR CONDITIONER DIMENSIONS (ROOF OF UNIT)
Above or Below
Level 5° Max
Level
Above Level 5° Max
Below Level 0° Max Figure 2
Note: Try you best to put the unit on the horizontal surface for operation. The unit can only operate for a short
time at the maximum sloping angle of 5º for preventing water leakage.
Level
Height Varies to Make Unit Level
Figure 3
1018
356x356
OPENING
- 17-
Level
Level
356
542
650 576
120
356
( )
Table of contents