Page 10 of 20 pages
Floor plate
European, national and local regulations must be observed in terms of the size and thickness of
a non-combustible floor covering the floor in front of the combustion chamber opening. Ask your
HWAM retailer for assistance. The combustion chamber opening is . cm wide.
Distance to combustible materials
Min. distances - uninsulated flue gas pipe (drawing A) HWAM 3740
HWAM 3760
. Recommended for brick wall 10 cm
. For combustible back wall 16.5 cm
. For combustible side wall 45 cm
.To combustible wall, corner installation, º 10 cm
. Distance to furnishings in front 105 cm
. For combustible wall, side, in front of the stove 45 cm
Min. distances - insulated flue gas pipe (drawing A) HWAM 3740
HWAM 3760
. Recommended for brick wall 10 cm
. For combustible back wall 11.5* cm
. For combustible side wall 22 cm
.To combustible wall, corner installation, º 10 cm
. Distance to furnishings in front 105 cm
. For combustible wall, side, in front of the stove 45 cm
Remember to pay attention to applicable regulations concerning the required distance between
the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM®Autopilot™ system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should
sometimes be treated as a combustible wall, in which case we ask you to contact your local
chimney sweep or glass producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sucient draught and prevent any smoke nuisance. As a
general rule, satisfactory draught conditions are achieved if the chimney is m above the stove
and at least cm above the ridge. If the chimney is placed at side walls, the top of the chimney
should always be higher than the ridge or the tallest point of the roof. Always be aware of any
national and/or local regulations applying to thatched roofs and the location of the chimneys.
The stove requires a draft of at least Pa.
The chimney must have a minimum clearing of Ø mm. The chimney must be provided with
an easily accessible cleaning door. The chimney and flue duct must be of flue class T and
be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing. The
required distance to combustible material must be complied with in accordance with the brand
label. Ask your HWAM retailer for further information.
Changing the smoke outlet from top outlet to back outlet - HWAM 3740 (drawing I)
If a wood-burning stove from the factory is supplied with a top outlet but you want to change it
to a back outlet, this can be done by following the instructions below. If this change is made, a
closed top plate without a hole for the top outlet can be purchased.