HYCON HY10000-WK08D User manual

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page2
Table of Contents
1. PACKAGE CONTENTS............................................................................................................................5
2. SAFETY PRECAUTIONS.........................................................................................................................6
3. SOFTWARE INSTALLATION REQUIREMENTS.....................................................................................7
3.1. Software Installation Requirements......................................................................................................7
3.2. Hardware Version Requirements..........................................................................................................8
3.3. Firmware Version Conversion...............................................................................................................8
4. WRITER ARCHITECTURE.....................................................................................................................10
4.1. Architecture Description......................................................................................................................10
4.2. Appearance introduction.....................................................................................................................10
4.3. Operating instructions......................................................................................................................... 11
4.4. Description of Writer Characteristics...................................................................................................12
4.5. Cautions..............................................................................................................................................13
5. PROGRAMMING SOFTWARE OPERATION INSTRUCTIONS ............................................................14
6. ON-LINE (PC) PROGRAMMING INSTRUCTIONS................................................................................15
6.1. Connect to burning OTP.....................................................................................................................15
6.2. Chip check(Blank Check)....................................................................................................................16
6.3. Burning chip (Program)......................................................................................................................17
6.4. Check chip(Verify)..............................................................................................................................17
6.5. Read chip(Read).................................................................................................................................18
6.6. Automatic burning and reading(AUTO).........................................................................................18
6.7. Cautions..............................................................................................................................................19
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page3
7. OFF-LINE (PC) PROGRAMMING INSTRUCTIONS..............................................................................20
7.1. Programming Instructions...................................................................................................................20
7.2. Limitation of Programming Times .......................................................................................................21
7.3. Cautions..............................................................................................................................................21
8. MESSAGES DESCRIPTION ..................................................................................................................22
8.1. Information Messages Description......................................................................................................22
8.2. Error Messages Description................................................................................................................24
8.3. Cautions..............................................................................................................................................27
9. REVISIONS.............................................................................................................................................28
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page4
Attention:
1. HYCON Technology Corp. reserves the right to change the content of this datasheet
without further notice. For most up-to-date information, please constantly visit our
website: http://www.hycontek.com.
2. HYCON Technology Corp. is not responsible for problems caused by figures or
application circuits narrated herein whose related industrial properties belong to third
parties.
3. Specifications of any HYCON Technology Corp. products detailed or contained herein
stipulate the performance, characteristics, and functions of the specified products in the
independent state. We do not guarantee of the performance, characteristics, and
functions of the specified products as placed in the customer’s products or equipment.
Constant and sufficient verification and evaluation is highly advised.
4. Please note the operating conditions of input voltage, output voltage and load current
and ensure the IC internal power consumption does not exceed that of package
tolerance. HYCON Technology Corp. assumes no responsibility for equipment failures
that resulted from using products at values that exceed, even momentarily, rated values
listed in products specifications of HYCON products specified herein.
5. Notwithstanding this product has built-in ESD protection circuit, please do not exert
excessive static electricity to protection circuit.
6. Products specified or contained herein cannot be employed in applications which
require extremely high levels of reliability, such as device or equipment affecting the
human body, health/medical equipment, security systems, or any apparatus installed in
aircrafts and other vehicles.
7. Despite the fact that HYCON Technology Corp. endeavors to enhance product quality
as well as reliability in every possible way, failure or malfunction of semiconductor
products may happen. Hence, users are strongly recommended to comply with safety
design including redundancy and fire-precaution equipment to prevent any accidents
and fires that may follow.
8. Use of the information described herein for other purposes and/or reproduction or
copying without the permission of HYCON Technology Corp. is strictly prohibited.
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page5
1. Package Contents
HY10000-WK08D integrated writer is a tool for connecting PC to program the chips. As
shown in Figure 1-1, HYCON HY10P/HY11P/HY12P/HY13P/HY15P/HY17P/HY16F series
products can be programmed through the integrated writer, the related hardware is
equipped as shown below:
Figure 1-1
No.
Model No.
Description
Quantity
HY10000-WK08D
1. HY10000-WK08D
Integrated Writer
1
2. Cable line
USB Type A to Mini B Cable
1
3. Programming line
6pin/2.0(2.0mm pitch)
1
4. Programming line
4*2Pin/2.54 (2.54mm pitch)
1
5. Power Supply
Output: DC 5V
1
Note:
HY10000-WK08C (previous generation products) is also an integrated writer, although its
appearance is slightly different from HY10000-WK08D, its functions are the same. This
chapter mainly introduces HY10000-WK08D only.
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page6
2. Safety Precautions
Do not place heavy objects on the display panel, in order to avoid damage caused by
stress.
Place the application display boards at steady place, so as to avoid falling damage.
Do not use this product with the input voltage which is not meeting the electrical
specifications, in order to avoid working abnormally or damage.
Avoid application display boards being touched by liquid, dirt and avoid being exposed
to moisture during operation. This application should be kept in a dry environment, so
as not to affect the function and performance.
Remove the power supply when not using it.
When following status occurred, please remove the power supply immediately, and
contact our engineer.
Power Supply line is worn or damaged.
Power source (battery) connected but no any light on while operating.
Component off.
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page7
3. Software Installation Requirements
3.1. Software Installation Requirements
Minimum System Requirements of operating HY10000-WK08D hardware:
(1) PC/NB hardware requirement:
IBM PC compatible X86 system CPU
512MB Memory (1GB recommended)
1GB Hard disk
(2) Supported Products:
HY10P/11P/12P/13P/15P/16F/17P series products
(3) Supported Hardware Model No.:
HY10000-WK08C & HY10000-WK08D writer kit
(4) Supported software version:
Support 8bit OTP IDE’s software version
HY10P IDE V3.4(including) above
HY11P IDE V4.5(including) above
HY12P IDE V3.9(including) above
HY13P IDE V3.6(including) above
HY15P IDE V2.2(including) above
HY17P IDE V1.1(including) above
Support Writer’s programming software version
HY10P and HY13P HexLoader V1.6(including) above
HY11P and HY12P HexLoader V2.5(including) above
HY15P HexLoader V1.9(including) above
HY17P HexLoader V1.0(including) above
HY16F Writer V2.3(including) above
(5) Supported Operating system:
Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10
(6) Apply the following interface modes:
USB Port with “HID-compliant device”
The HY10000-WK08D's USB Port driver uses the Windows standard
“HID-compliant device”(Figure 3-1), so there is no need to install another USB
driver.
Figure 3-1
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page8
3.2. Hardware Version Requirements
The firmware versions of each product to be matched with the writer are as follows:
Firmware of HY10P/HY13P series products uses W13AD1.6(including) above
Firmware of HY11P/HY12P series products uses WRIV2.40(including) above
Firmware of HY15P series products uses W15P02.3(including) above
Firmware of HY17P series products uses W17D01.6(including) above
Firmware of HY16F series products uses V3.4(including) above
3.3. Firmware Version Conversion
HY10000-WK08D integrated writer supports HY10P/HY11P/HY12P/HY13P/HY15P/
HY17P & HY16F series products, and it’s internal firmware can only be used for one family
of products per conversion, before different firmware conversion, you can view the current
firmware version through the “information 1” message.
The integrated writer needs to cooperate with the “Burner Transformer” software to
convert the internal firmware of the writer to support the programming of different series of
products, the conversion method is as follows:
(1) Short circuit Pin1~Pin2 of the “Handler” interface of the integrated writer, as shown
in Figure 3-2:
Figure 3-2
(2) Connect the integrated writer to the computer through the USB cable, at this time,
the LED lights on the writer will be off, after opening software , the interface as
shown in Figure 3-3a will appear, and then click the "connect" button to connect.
Figure 3-3a Figure 3-3b
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page9
(3) Start update:
Select the firmware version to be upgraded (as shown in figure 3-3b) in the "IC serial"
drop-down menu, and then click "transform" to start the update.
If the update is OK, the progress bar will display 100%, and a message window will
appear (as shown in Figure 3-4) indicating that the firmware has been downloaded
successfully, at this time, close the software, unplug the USB cable and remove the
short circuit.
Figure 3-4
Note:
For more information about the “Burner Transformer” software, please refer to the
“APD-HYIDE014_EN”document ( HY10000-WK08x Integrated Writer Online Update
Manual).
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page10
4. Writer Architecture
4.1. Architecture Description
The HY10000-WK08D is a programming device between the Chips to be programmed
and the writer software, the assembly diagram is as follows:
Figure 4-1
4.2. Appearance introduction
The integrated writer is a tool for programming chips, it can burn HY10P/ HY11P/
HY12P/HY13P/HY15P/HY17P & HY16F series products through the integrated writer, as
shown in Figure 4-2:
P4 LCM
S3 S2 S1 L1L2L3
U11
P1 P3
Figure 4-2
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page11
4.3. Operating instructions
The following table shows the description of each device:
Item
Descriptions
U11
USB Connector:
It is also a 5V power supply port that can be connected with the PC, and
through the USB port, the Hex & Bin code to be programmed can be
downloaded through USB port for HY10P/11P/12P/ 13P/15P/16F/17P series
products.
P1
Programming Control Port:
The port is connected to the chip’s programming pins, and can supports 8-bit
and 32-bit MCU product programming pins as follows:
8-bit OTP MCU dedicated programming pin:
VSS, VDD, PSDO, PSDI, PSCK, VPP (as shown in Figure 4-3a)
32-bit Flash MCU (HY16F series product) dedicated programming pin:
VSS, VDD, ECK, EDIO, NC, RST (as shown in Figure 4-3b)
( For HY10/11/12/13/15/17 )
VPP VSS
VDD
PSCK
PSDI PSDO
( For HY16F )
RST VSS
VDD
NC
EDIO ECK
Figure 4-3a Figure 4-3b
P3
Extended Programming Port:
Refer to Figure 4-3c for the definition of each pin name and figure 4-3d for the
specific connection line, where~
Program(S1)、Blank(S2)、OK(L1)、Error(L2)、Busy(L3)
Busy
Blank
VSS
Error
OK
Program
VDD
Update
Program
Blank Error
OK
Busy
VDD
S2 L1
L2L3
VSS
S1
Figure 4-3c Figure 4-3d
L1
Action success indicator (OK LED):
Programming success message indicator.
L2
Action failure indicator (Error LED):
This message indicator will be on in case of programming failure, blank
checking failure and HAO frequency calibration failure.
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page12
L3
Busy message indicator (Busy LED):
When the Writer is programming, this message indicator will be on.
S1
Program:
Chip programming button.
S2
Blank Check:
Chip blank checking button(HY16F product has no this function).
S3
Information:
Information inquiry button of the Writer.
4.4. Description of Writer Characteristics
No
Item
Description
1
Model of Writer
HY10000-WK08D & HY10000-WK08C
2
Supporting chip Model
HY10P/11P/12P/13P/15P/16F/17P Series
3
Power on self- check
mechanism
High
4
Programing times counting
Support
5
Hardware calibration
function of chip frequency
2MHz/4MHz/8MHz HAO (8-bit MCU only)
6
Software calculation function
of chip frequency difference
HAO and LPO (8-bit OTP MCU only)
7
“Auto button” function
Blank, Program, Verify
8
LED light indicator
Green LED(L1), Red LED(L2), Yellow LED(L3)
9
IDE software support version
(For 8-bit OTP MCU only)
Please refer to chapter 3.1 for supporting version:
10
Programming code
download support
You need to download the programming code to the
Writer through the programming software.
11
Programming software
support version
Please refer to chapter 3.1 for supporting version:
Special programming software is provided for each
product, which can download the code to be
programmed to the Writer, to provide on-line or off-line
programming function for the chip by the Writer.
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page13
Notice:
1. Supporting chip model: HY10000-WK08D can program HY10P/HY11P/HY12P/HY13P
/HY15P/HY17P & HY16F series chips.
2. Program self-checking mechanism at startup: HY10000-WK08D is a high-level self
checking mechanism at startup to ensure the correctness of data, when power on, it
will check whether the code to be programmed is correct or not and Checksum is
correct or not, therefore, the LCM screen will display "Verifying….”string, If the check
is passed, the "HYCON IDE" string will appear to ensure the correctness of the data,
which means that the Writer can be started; if the check fails, the "Verify error 6" string
will appear, which means that the code to be programmed is not correct, and the code
to be programmed must be downloaded again.
3. Allowed chip programming times: HY10000-WK08D supported.
4. Chip frequency hardware calibration function: HY10000-WK08D supports the
hardware calibration function of 2MHz/4MHz/8MHz HAO frequency.
5. Software calculation function of chip frequency difference: HY10000-WK08D supports
the software difference calculation function of HAO frequency and LPO frequency.
6. Auto button function: HY10000-WK08D automatic programming sequence is Blank →
Program → Verify.
7. LED light: Green(L1) / Red(L2) / Yellow(L3) light of HY10000-WK08D respectively
represents OK / Error / Busy, when the L3(Busy) message indicator is on during the
programming process, the L3(Busy) message indicator is off after the programming is
completed, When L1 is on, it means the programming is successful, and when L2 is on,
it means the programming is failed or the HAO frequency correction is failed.
8. There is no frequency calibration function for HY16F series chip programming
4.5. Cautions
1. If the HY10000-WK08D Writer displays
Error 6
Verify Fail!
at the first time of startup, it is
caused by the code to be programmed has not been downloaded to the flash of the
Writer, not because the Writer is damaged, so the user does not need to pay attention
to this error message.
2. When HY10000-WK08D Writer use the "limit programming times" function, assuming
that the programming times are used up, pressing the “Program”button will display
Error 8
Program Count=0
and cannot program, pressing the “Information”button will display
"Information 2”: program counter enable left 00000000".
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page15
6. On-Line (PC) Programming Instructions
Only 8-bit OTP chip is introduced below, for HY16F series products, please refer to
"APD-HY16IDE006_EN" document directly.
6.1. Connect to burning OTP
Determine the burn chip model selected under the title window, as shown in
Figure 6-1, Figure 6-2. The same as the OTP model, when the burner performs Blank
Check, burn and Verify, the program will compare the settings to select whether the chip
model and the flashed OTP model are the same, if not otherwise it will not be burned into
the OTP, the error message is displayed in the message bar, as shown in Figure 6-3.
Show Code Blank Check Programming Verify Read Auto
Figure 6-1
Figure 6-2
When the file is successfully loaded into the burner or the Flash Memory of the IDE.
The blank check, burn, verify, and read actions will be possible. If the file is not loaded
successfully, the blank check, burn, verify, and read actions will not succeed.
The setting chip model is different
from the model of the OTP
Figure 6-3
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page16
Before burning, if want to check the model is correct, point the mouse indicator to the
"Chip Connection Status Display Area" and press the left mouse button, if the chip
model is correct, it is displayed, as shown in Figure 6-4; if it is incorrect, it is displayed as
shown in Figure 6-5; If "Enable Program Times" is checked, the remaining number of
burns will be displayed in the message bar, as shown in Figure 6-6.
The IC model of the OTP
has been connected
Figure 6-4
The IC model of the OTP
has not been connected
Figure 6-5
Figure 6-6
6.2. Chip check(Blank Check)
The Blank Check in a chip that has not yet been burned, the code inside the chip
should be read as a 0xFFFF, and the purpose of the chip check is to determine that the
contents of all addresses of this OTP are 0xFFFF. Checking if the chip is empty means that
the contents of the OTP address to be burned are 0xFFFF. If the chip is selected correctly
and the check is empty, the following message appears in the message bar, as shown in
Figure 6-7.
Figure 6-7
If the chip is selected incorrectly or the check is not empty, the following message
appears in the message bar, as shown in Figure 6-8.
Figure 6-8
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page17
6.3. Burning chip (Program)
The programming chip (Program) is shown in , The purpose of burning is to burn the
program that has been completed by Compiler into the OTP chip, and after the finished
product is assembled after the burning is completed, the program can be run according to
the instructions written by the user.
If the chip is selected correctly and the burn is successful, the following message
appears in the message bar, as shown in Figure 6-9, if "Enable Program Times" is checked,
the number of burns allowed will be reduced by 1, and the remaining number of burns will
be displayed in the message bar.
The number of burning remaining
If you check "Enable Program Times."
Figure 6-9
If the chip is selected incorrectly and the programming is not successful, the following
message appears in the message bar, as shown in Figure 6-10
Figure 6-10
6.4. Check programming chip (Verify)
Verify the programming chip (Verify) is shown as , the purpose of verifying the
programming chip is to compare whether the program programmed into the OTP chip is the
same as the program loaded into the programmer.
Confirm whether the content of the programmed chip is consistent with the downloaded or
assembled Hex fil e (displayed in the bottom display column). If the chip has been
programmed and protected, this item is invalid or the comparison fails.
If the selected chip is correct and the programming is confirmed successfully, the
following message will appear in the message column, as shown in Figure 6-11.
Figure 6-11
If the chip is selected incorrectly or the programming is confirmed to be unsuccessful,
the following message appears in the message bar, as shown in Figure 6-12.
Figure 6-12
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page18
6.5. Read chip(Read)
The purpose of reading the chip is to let the user confirm that the Checksum reading
OTP is the same as the Hex file. Read the chip content, as shown in Figure67-13, and
display the content in the "Show Code" window; If the chip has been programmed to protect,
this entry is invalid or the comparison fails.
Display the OTP CODE
Display the OTP Checksum
Display the OTP model
Figure 6-13
6.6. Automatic programming and reading (AUTO)
AUTO is shown as, Auto is a combination of three functions of Blank Check, Program
and Verify. Selecting Auto will first check whether the chip is empty, and then program to
confirm the programming chip.
When the execution is successful, the following message will appear in the message
bar, as shown in Figure 6-14. If “Enable Program Times” is checked, the number of allowed
programming times will be reduced by 1, and the remaining programming times will be
displayed in the message bar.
Figure 6-14
If there is a failure, the entire process stops immediately and an error message is
displayed in the message bar.
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page19
6.7. Cautions
HY16F series programming function is different from 8-bit OTP chip products, which is
not fully applicable to the above functions (such as no voltage, frequency calibration, etc.),
please refer to HY16F series programming operation manual ( http://www.hycontek.com/ ).
.

HY10000-WK08D
Integrated Writer User’s Manual
© 2023 HYCON Technology Corp
www.hycontek.com
APD-HYIDE013-V06_EN
page20
7. Off-Line (PC) Programming Instructions
Only 8-bit OTP chip is introduced below, for HY16F series products, please refer to
"APD-HY16IDE006_EN" document directly.
7.1. Programming Instructions
When the user program enters the mass production stage from the development stage,
it is programmed on the production line, at this time, the Writer can be used independently
without connecting to the PC.
P4 LCM
S3 S2 S1 L1L2L3
U11
P1 P3
(Please refer to Section 4.3 for description of each device)
The following table shows the description of the LED indicator and buttons:
Item
Descriptions
L1
Action success indicator (OK LED):
Programming success message indicator.
L2
Action failure indicator (Error LED):
This message indicator will be on in case of programming failure, blank
checking failure and HAO frequency calibration failure.
L3
Busy message indicator (Busy LED):
When the Writer is programming, this message indicator will be on.
S1
Program:
Chip programming button.
S2
Blank Check:
Chip blank checking button(HY16F product has no this function).
S3
Information:
Information inquiry button of the Writer.
During Off-Line programming operation, it is necessary to download the programmed
code (HEX or BIN file) into flash memory of the Writer, please refer to the user manual
of Writer’s programming software.
.
Table of contents
Other HYCON Computer Hardware manuals
Popular Computer Hardware manuals by other brands

COMMUNICATIONS-APPLIED TECHNOLOGY
COMMUNICATIONS-APPLIED TECHNOLOGY ICRI Setup and operating procedures

Renesas
Renesas H8/36024 user manual

IEI Technology
IEI Technology SPCIE-C2260-i2 user manual

Dinstar
Dinstar DXP60 user manual

T L Audio
T L Audio VP-1 user manual

Multitech
Multitech RouteFinder RF802WLC quick start guide