
CONTENTS
IBM 2740 COMMUNICATION TERMINAL, MODEL 1 . 1
Types of O peration
.....................................................................................
2
A p p lica tio n s...............................................................................................3
Communication F acilities............................................................................3
Data Sets ...............................................................................................4
Line-Control S ig n a ls .....................................................................................4
TRANSMISSION CONTROLS AND INDICATORS, MODEL 1 . 7
Local/Communicate Key. ....... 7
Standby S) L i g h t ......................................................................................7
Transmit T) L ig h t......................................................................................7
Receive R) L i g h t ......................................................................................7
Bid Key and L i g h t ......................................................................................7
Restart RST) Key and Light Checking Special F eature) 8
Dial-Disconnect Disc) Key and Dial-Connect Light Dial-
Up Adapter Special F e a t u r e )
.........................................................
8
EOB End-of-Block) Key Checking Special Feature) . . 9
Automatic EOB Prerequisite, Checking Feature) . . 9
EOT End-of-Transmission) K e y ........................................................10
Transmit-Control Switch MTC, Off) Transmit Control
Special F e a tu r e ....................................................................................10
Test S w i t c h .............................................................................................10
PRINCIPLES OF OPERATION, 2740 MODEL 1 . . . . 11
Point-to-Point Operation Terminai-to-Terminal) . . 11
Broadcast Operation....................................................................................12
Dial-Up O p eration ....................................................................................13
Dial-Up Operation with c h e c k i n g )
..............................................
13
Point-to-Point Operation--Multiplexer and Terminal . 14
Point-to-Point Operation--Multiplexer and Terminal
with Dial-Up Feature Installed........................................................15
Transmit C ontrol--M u ltiplexer........................................................16
Station Control--Multiplexer Addressing and Polling . 16
SPECIAL FEATURES, MODEL 1 17
Dial-Up A d a p t e r ....................................................................................17
Transmit Control Prerequisite, Dial-Up Adapter Feature) 17
Automatic Disconnect Feature World Trade Only) . . 18
Checking - -Parity VRC) and Block LRC) .... 19
Station Control Multiplexer Addressing and Polling) . 19
Automatic EOB Prerequisite , Checking Feature) . . 21
IBM 2760 A tta c h m e n t..........................................................................22
IBM Line Adapter Limited-Distance Type 1) . . 2 2
IBM Line Adapter Limited-Distance Type 2) . . . 22
IBM Line Adapter Leased L i n e ) .......................................................22
IBM Line Adapter Shared L i n e ) .......................................................22
Pin-Feed P l a t e n s ...................................................................................22
Paper Guide, Tear Bar, and Roll Paper Holder . . . 23
Timing Considerations, 2740 Model 1 ..............................................23
Time-Out C o n d itio n s ..........................................................................23
Delay C o n d itio n s ...................................................................................23
Typewriter Delay C o n d i ti o n s .......................................................23
Data-Handling Capability, Model 1 ..............................................24
Terminal Transmission and Control Speed .... 24
Addressing T i m e ...................................................................................24
Polling Time Negative Answer B a ck )..............................................24
Polling Time Positive Answer B a c k ) ..............................................24
Checking Time Receive Terminal, Positive Answer Back) 24
Checking Time Receive Terminal, Negative Answer Back) 24
Checking Time Transmit Terminal, Positive Answer Back) 24
Checking Time Transmit Terminal, Negative Answer
B a c k ) ......................................................................................................24
IBM 2740 COMMUNICATION TERMINAL, MODEL 2 . . 27
Introduction..............................................................................................27
Communication F acilitie s..................................................................28
Data S e t s ..............................................................................................28
Modes of O p e r a tio n
...........................................................................
28
Local M o d e .....................................................................................28
C om m u nicate.....................................................................................29
Codes, Keyboard Arrangements, and Print Elements . 29
Transmission Controls and Indicators, Model 2 . . . 29
On/Off Power S w i t c h ..................................................................29
Keys ..............................................................................................29
S w itc h e s ..............................................................................................30
Indicator L i g h t s ...........................................................................31
Without Buffered Receive and Without Record Checking
Special Features In sta lled
........................................................
33
With Buffered Receive and Without Record Checking
Special Features In stalled
........................................................
33
With Record Checking and Without Buffered Receive
Special Features Installed ....... 33
With Record Checking and With Buffered Receive
Special Features In stalled .........................................................34
PRINCIPLES OF OPERATION, MODEL 2 ......................................35
Local M o d e .....................................................................................35
Communicate M o d e ..................................................................35
Station Control Multiplexer Addressing and Polling) . 36
P o l l i n g ..................................................................
.........
36
Addressing..............................................................................................36
SPECIAL FEATURES, MODEL 2
...............................................
39
Buffer Expansion . .
.
........................................................39
Record C h e c k in g ........................................................................... 39
Operation
.
....................................................................................39
Transmitting T erm in al..................................................................39
Receiving Term inal
...........................................................................
39
Buffered R e c e i v e ...................................................................................40
Telegraph Line A d ap te r..........................................................................40
Speed Base—600 b p s ..........................................................................40
Header C o n t r o l ...................................................................................40
Edit 40
Split Friction-Feed P l a t e n .........................................................41
Document I n s e r t i o n ..................................................................41
Ledger-Card S t o c k
...........................................................................
43
Operation
.
.............................................................................................43
Document D e s ig n ...........................................................................43
Paper Guide, Tear Bar, and Roll Paper Holder . . . 44
Pin-Feed P l a t e n s ...................................................................................44
IBM Line Adapter Limited-Distance Type 1) . . 4 4
IBM Line Adapter Limited-Distance Type 2) . . 4 5
IBM Line Adapter Leased L i n e )
...............................................
45
IBM Line Adapter Shared L i n e )
...............................................
45
Timing Considerations, Model 2 .................................................46
Typewriter Delay C o n d i ti o n s
...............................................
46
IBM 2740 Model 2 Data-Handling Capability . . . 46
G LO SSA RY..............................................................................................47
A P P E N D IX ..............................................................................................49
INDEX
Contents iii