Specifications and features
The following table provides a summary of the features and specifications for your
server.
1
Table 1. Features and specifications
Microprocessor:
vIntel Xeon
™
MP
v1 MB or 512 KB level-3 cache
depending upon model
v400 MHz front-side bus (FSB)
vSupport for up to four
microprocessors with Intel
Hyper-Threading technology and
Intel NetBurst
™
microarchitecture
Memory:
vMaximum: 12 GB
vType: ECC, double-data rate (DDR),
SDRAM, registered DIMMs
vSlots: two-way or four-way
interleaved, 12 slots
vHot Spare memory
Drives standard:
vDiskette: 1.44 MB
vCD-ROM: IDE
Available expansion bays:
vHot-swap:
– Six slim-high in upper drive cage
– Six slim-high in lower drive cage
with optional SCSI backplane
installed
vNon-hot-swap: Two 5.25-inch
Expansion slots:
vSix hot-plug PCI-X 100 MHz/64-bit
vOne non-hot-plug PCI 33 MHz/32-bit
Hot-swap power supplies:
370 W (115-230 V ac)
vMinimum: Two
vMaximum: Four for redundancy
Redundant cooling:
Nine hot-swap fans
Video:
vATI RageXL video controller
vCompatible with SVGA and VGA
v8 MB video memory
Size (tower model):
vHeight: 356 mm (14.0 in.)
vDepth: 700 mm (27.6 in.)
vWidth: 483 mm (19 in.)
vWeight:47kg(104lb)to55kg(121.2
lb) depending upon configuration
Size (7 U) (rack model):
vHeight: 311 mm (12.3 in.)
vDepth: 650 mm (25.6 in.)
vWidth: 440 mm (17.3 in.)
vWeight:47kg(104lb)to55kg(121.2
lb) depending upon configuration
Integrated functions:
vDual-channel Ultra160 SCSI controller
(one internal and one external channel)
vWake on LAN
®
support
vOne Broadcom 10/100/1000 Mbps
Ethernet controller
vOne serial port
vFour Universal Serial Bus ports
vKeyboard port
vMouse port
vVideo port
vIntegrated system management
processor (ISMP) with two ISMP
(RS-485) RJ-45 connectors
Acoustical noise emissions:
vSound power, idle: 6.3 bel maximum
vSound power, operating: 6.3 bel
maximum
vBystander (1 m) Sound pressure,
operating: 47 dBa maximum
vBystander (1 m) Sound pressure, idle:
47 dBa maximum
Environment:
vAir temperature:
– Server on: 10° to 35°C (50° to 95°F).
Altitude: 0 to 914 m (3000 ft).
– Server on: 10° to 32°C (50° to 89.6°F).
Altitude: 914 m (3000 ft) to 2133 m
(7000 ft).
– Server off: 10° to 43°C (50° to 110°F).
Maximum altitude: 2133 m (7000 ft).
vHumidity:
– Server on: 8% to 80%
– Serveroff:8%to80%
Heat output:
Approximate heat output in British thermal
units (Btu) per hour
vMinimum configuration: 461 Btu (0.14
kilowatts)
vMaximum configuration: 3412 Btu (1.0
kilowatts)
Electrical input:
vSine-wave input (50-60 Hz) required
vInput voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
vInput voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
vInput kilovolt-amperes (kVA) approximately:
– Minimum: 0.08 kVA
– Maximum: 1.07 kVA
Notices and statements used in this book
The caution and danger statements used in this book also appear in the multilingual
Safety Information book provided on the IBM xSeries Documentation CD. Each
caution and danger statement is numbered for easy reference to the corresponding
statements in the safety book.
The following types of notices and statements are used in this book:
vNote: These notices provide important tips, guidance, or advice.
1. Racks are marked in vertical increments of 1.75 inches each. Each increment is referred to as a unit, or ″U.″A 1-U-high device is
1.75 inches tall.
2IBM xSeries 255 Type 8685: Installation Guide