Adjustment for IC-F620
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Preparation Connect the transceiver by cloning cable
(OPC-1122) to a PC (IBM compatible) and
boot up the cloning software.
Check points Be sure to use a tester with more than 50
kohm/V internal resistance when making
each test.
Lock Voltage Set the transceiver to the 400 MHz
Adjustment and set so that the LV voltage is
C133 during RX and C134 during TX.
Adj. Freq. 400 MHz
RX Side 1.0V 1.0V C133 LV
TX Side 1.1V 1.1V C134
Lock Voltage Set the transceiver to the 490 MHz
Check and check that all is within specification.
Adj. Freq. 430 MHz
RX Side 3.0V~4.2V 3.0V-4.2V LV
TX Side 3.0V~4.2V 3.0V-4.2V
Frequency Connect a power meter or attenuator
Adjustment to the antenna terminal.
Loose coupling the antenna terminal
and frequency counter.
Set the transceiver to near the TX greatest
high band frequency and set the unit to TX.
Use adjustment software to adjust the TX
frequency to the values below.
Set Frequency Set Freq. ±500 Hz ±500Hz Adj.Soft ANT Con
TXF
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
TX Output Use adjustment software to adjust the
adjustment output to the values below.
Adj.Soft
Adj. Freq. Greatest Low Band Freq. Power
Hi Power 25.0W 25.0W Hi ANT Con
L2 Power 10.0W 10.0W L2
L1 Power 2.5W 2.5W L1
TX Output Check Check that the in-band TX output is within
the specifications below.
Hi Power 20.0~30.0W 20-30W ANT Con
L2 Power 8.0~12.5W 8 -12.5W
L1 Power 2.0~3.0W 2.0-3.0W
Current Check at Check that the in-band power consumption
TX is within the specifications below.
Hi Power Less than 7.0A Less 7.0A
Checking Connect a spectrum analyzer to the ANT
Spurious terminal through an attenuator.
Set the attenuation so that the spectrum
Analyzer does not distort.
Set the transceiver to TX and when at Hi
power, check that spurious is less than the
value below in the bandwidth.
Spurious Less than –70dB of the Less than ANT Con
fundamental wave -70 dB
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Preparation for When there is no particular set limits, set
Checking Modula-the modulation analyzer for adjustment and
tion Adjustment checking as below.
HPF OFF
LPF 20 kHz
De-Emphasis OFF
Detector (P ±P)/2
Connect the modulation analyzer set at the
above conditions, through the attenuator to
the antenna terminal. Connect an oscillo-
scope, distortion meter and a level meter to
the modulation analyzer’s detection output
terminal.
Connect a millivolt meter or a 600 ohm out-
put impedance CR oscillator to the trans-
ceiver’s mic terminal.
Modulation Use the adjustment software to adjust the
Balance modulation analyzer’s detection output
Adjustment horizontal line so that it becomes a
Straight line as below
Adjust. Freq. Near Center Frequency
Detection Adj.Soft ANT Con
Output Balance
Deviation Set the CR oscillator to a 1 kHz sine wave,
Adjustment 40mVrms, and input from the external mic
terminal. Set the transceiver to TX and use
the adjustment software to adjust to the
following values.
Adjust. Freq. Near Center Frequency ±4.05 ~ Adj.Soft ANT Con
WIDE ±4.10 ±0.05 kHz ±4.15kHz MOD W
NARROW ±2.10 ±0.05 kHz ±2.05 ~ MOD N
±2.15kHz
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Checking Check that the deviation in the bandwidth
Deviation is as the values below.
±3.6 ~ ANT Con
WIDE ±3.60 ~ 4.50 kHz ±4.5kHz
NARROW ±1.80 ~ 2.30 kHz ±1.8 ~
±2.3kHz
Checking Modula-Check that the modulation in the bandwidth
tion is as the value below
WIDE/NARROW 2.8 ~ 6 mV rms 2.8-6mV ANT Con
WIDE:±3 KHz DEV ; NARROW:±1.5 KHz DEV rms
CTCSS Deviation Connect a linear detector via the attenuator
Adjustment to the antenna terminal, Set the transceiver
to wide ch and CTCSS 88.5Hz.
Transmit while making sure no input is
applied to the mic (or mic terminal)
Adjust. Freq. Near Center Frequency Adj.Soft ANT Con
WIDE ±0.7 kHz ±0.7kHz CTCS/DTCS
Checking CTCSS/ then reset so that each signaling type
DTCS/2/5 TONE/ can be output.
DTMF DEVIATION DTCS CODE 007
CTCSS 88.5 Hz
5 TONE CCIR 11111
DTMF # (Auto Dial Setting)
2 TONE 349.0 Hz
check that each version in it’s bandwidth
is as the values below, respectively.
Wide CTCSS/DTCS ±0.50~±0.90kHz ±0.5-0.9kHz ANT Con
Wide 2/5 TONE/ ±2.40~±3.60kHz ±2.4-3.6kHz
DTMF
Narrow CTCSS/DTCS ±0.25~±0.45kHz ±.25-.45kHz
Narrow 2/5 TONE/ ±1.20~±1.80kHz ±1.2-1.8kHz
DTMF
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Checking TX S/N Connect a linear detector via the attenuator
to the antenna terminal, and set to the
conditions below.
HPF 50 Hz
LPF 20 kHz
De-emphasis OFF
Level Meter ( P/P)/2
Apply a 1 kHz signal from the low frequency
oscillator to the mic terminal, and
transmit, then adjust the low frequency
oscillator output level so that the maximum
modulation is 70%.(WIDE:3.5KHz,NAR:1.75KHz)
Check that the TX S/N in the bandwidth is
as the values below.
WIDE More than 40 dB Over 40dB ANT Con
NARROW More than 34 dB Over 34dB
Adjusting RX When there is no particular set limits, set
Sensitivity the RX adjustments and signal generator
when checking to the settings below.
Modulation Freq. 1kHz
WIDE ±3.5 kHz
NARROW ±1.75 kHz
Set the signal generator in the following
way for wide channels.
Adjust Freq. Near Greatest Lo band F.
SG Input level +20 dBu
Connect an 4 ohm non-inductive load and Adj.Soft RSSI line
a distortion meter to the external speaker
terminal. Adjust BPF (T1) ~ (T4) with the
adjustment software, so that the sensitivity
is at maximum.
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Checking RX Check that the signal generator level when
Sensitivity the RX frequency bandwidth becomes 12 dB
SINAD, is the value below.
RX Sensitivity Less than -10 dBu Less-10dB ANT Con
SP Jack
Use the same check method for Narrow
channels also.
Adjusting the This Adjustment is after the RX Sencitivity
S3 LEVEL Finish.
Set the signal generator in the following
way for wide channels.
Adjust Freq. Near Greatest Lo band F.
SG Input level +23 dBu
Modulation Freq. 1kHz
WIDE ±3.5 kHz
S3 SET COMMAND with the Adjustment soft Adj.Soft ANT Con
Ware. S -METER
S3 Level
Adjusting the Set the signal generator to the settings
S1 LEVEL below.
SG Output Level -7 dBu
S1 SET COMMAND with the Adjustment soft Adj.Soft ANT Con
Ware. S -METER
S1 Level
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Adjusting the set the transceiver to the RX frequency
Squelch bandwidth’s narrow band center frequency.
Set the signal generator to the settings
below. ANT Con
Modulation Freq. 1kHz
WIDE ±3.5 kHz
NARROW ±1.75 kHz
SG Output Level -14 dBu
In this condition, using the adjustment Adj.Soft
software, raise the squelch D/A value until SQL
the squelch closes once, then lower the D/A
value again, and adjust until the squelch
opening point.
Checking Squelch Check that the squelch opening point value
Sensitivity in the RX frequency bandwidth is as below.
Squelch Sensitivity Less than –10 dBu Less-10dB ANT Con
Next, reduce the signal generator output
and check that the squelch closes in the RX
bandwidth.
ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Checking Set the signal generator output level to
AF Output +60 dBu. The transceiver and SG connection
is the same as the squelch adjustment above.
Adjust the transceiver volume until the
distortion meter reads 5%.
Check that the AF output value at this point
as below.
Over ANT Con
AF Output More than 3.5 W 3.5 W SP Jack
@ 4 ohm
load
Checking RX S/N Set the signal generator output level to
+60 dBu. Adjust the AF volume so that the
AF output is 50% of the rated value.
Check that the RX S/N in the bandwidth is
as the values below.
WIDE More than 40 dB Over 40dB ANT Con
NARROW More than 34 dB Over 34dB SP Jack
Checking Set the signal generator output to +60 dBu
Howling as in RX adjustment, and for non modulation. ANT Con
set the internal speaker for operation, Int SP
and turn the AF volume up to maximum to
check that howling does not occur.
Checking While still in the AF output check status,
Maximum rotate the volume control clockwise to
RX Current obtain the maximum AF output. Check that the
current consumption at this time is as the
value below.
Max. RX Current Less than 1200 mA Less than PWR Con
1200mA

Other manuals for IC-F620

3

This manual suits for next models

1

Other Icom Transceiver manuals

Icom IC-T10 Installation guide

Icom

Icom IC-T10 Installation guide

Icom IC-V82 User manual

Icom

Icom IC-V82 User manual

Icom IC-A24 User manual

Icom

Icom IC-A24 User manual

Icom IC-F6020 Series User manual

Icom

Icom IC-F6020 Series User manual

Icom IC-F110 User manual

Icom

Icom IC-F110 User manual

Icom IC-M710 User manual

Icom

Icom IC-M710 User manual

Icom IC-M220 User manual

Icom

Icom IC-M220 User manual

Icom IC-2000H User manual

Icom

Icom IC-2000H User manual

Icom IC-DELTA100H User manual

Icom

Icom IC-DELTA100H User manual

Icom IC-7300 User manual

Icom

Icom IC-7300 User manual

Icom iDAS IC-F3102D User manual

Icom

Icom iDAS IC-F3102D User manual

Icom IC-F52D User manual

Icom

Icom IC-F52D User manual

Icom IC-F70T User manual

Icom

Icom IC-F70T User manual

Icom IC-M35 User manual

Icom

Icom IC-M35 User manual

Icom IC-A200 User manual

Icom

Icom IC-A200 User manual

Icom IC-7610 User manual

Icom

Icom IC-7610 User manual

Icom IC-F70DS User manual

Icom

Icom IC-F70DS User manual

Icom IC-M421 User manual

Icom

Icom IC-M421 User manual

Icom IC-E7 User manual

Icom

Icom IC-E7 User manual

Icom IC-F3162T User manual

Icom

Icom IC-F3162T User manual

Icom IC-7000 User manual

Icom

Icom IC-7000 User manual

Icom IC-9700 User manual

Icom

Icom IC-9700 User manual

Icom IC-78 User manual

Icom

Icom IC-78 User manual

Icom IC-F4029SDR User manual

Icom

Icom IC-F4029SDR User manual

Popular Transceiver manuals by other brands

evertz 7707IT manual

evertz

evertz 7707IT manual

Microwave Data Systems MDS 2710D Installation & operation guide

Microwave Data Systems

Microwave Data Systems MDS 2710D Installation & operation guide

Standard Horizon QUANTUM GX6500E owner's manual

Standard Horizon

Standard Horizon QUANTUM GX6500E owner's manual

Kenwood Nexedge NX-820H Service manual

Kenwood

Kenwood Nexedge NX-820H Service manual

ATC Technology ATC-2000WF user manual

ATC Technology

ATC Technology ATC-2000WF user manual

Vertex Standard GX1600 Alignment Guide

Vertex Standard

Vertex Standard GX1600 Alignment Guide

Semtech SX1261 user guide

Semtech

Semtech SX1261 user guide

Super Star 360 owner's manual

Super Star

Super Star 360 owner's manual

Kenwood NX-3000 series user guide

Kenwood

Kenwood NX-3000 series user guide

General Lee Full Channel AM/FM Amateur Mobile... owner's manual

General Lee

General Lee Full Channel AM/FM Amateur Mobile... owner's manual

NavCom Technology NavComm SL30 user guide

NavCom Technology

NavCom Technology NavComm SL30 user guide

QRPGuys Digital DSB II Transceiver Kit instructions

QRPGuys

QRPGuys Digital DSB II Transceiver Kit instructions

DZ PSKUBE PSQ-100 Assembly manual

DZ

DZ PSKUBE PSQ-100 Assembly manual

BWI Eagle AIR-EAGLE SR PLUS Product information bulletin

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS Product information bulletin

Kenwood TK-272G Service manual

Kenwood

Kenwood TK-272G Service manual

Yaesu FT-891 operating manual

Yaesu

Yaesu FT-891 operating manual

Kenwood TK-860G series Service manual

Kenwood

Kenwood TK-860G series Service manual

Yaesu FT-780R instruction manual

Yaesu

Yaesu FT-780R instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.