manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ICP DAS USA
  6. •
  7. Control Unit
  8. •
  9. ICP DAS USA tM-AD4P2C2 User manual

ICP DAS USA tM-AD4P2C2 User manual

Other manuals for tM-AD4P2C2

1

Other ICP DAS USA Control Unit manuals

ICP DAS USA ET-2260 User manual

ICP DAS USA

ICP DAS USA ET-2260 User manual

ICP DAS USA I-8026W User manual

ICP DAS USA

ICP DAS USA I-8026W User manual

ICP DAS USA SG-785 User manual

ICP DAS USA

ICP DAS USA SG-785 User manual

ICP DAS USA ET-87P2 User manual

ICP DAS USA

ICP DAS USA ET-87P2 User manual

ICP DAS USA ET-2200 Series User manual

ICP DAS USA

ICP DAS USA ET-2200 Series User manual

ICP DAS USA tGW-700 Series User manual

ICP DAS USA

ICP DAS USA tGW-700 Series User manual

ICP DAS USA I-7063 User manual

ICP DAS USA

ICP DAS USA I-7063 User manual

ICP DAS USA GPS-721-MRTU User manual

ICP DAS USA

ICP DAS USA GPS-721-MRTU User manual

ICP DAS USA SG-3227 User manual

ICP DAS USA

ICP DAS USA SG-3227 User manual

ICP DAS USA M-7002 User manual

ICP DAS USA

ICP DAS USA M-7002 User manual

ICP DAS USA I-8092F Parts list manual

ICP DAS USA

ICP DAS USA I-8092F Parts list manual

ICP DAS USA ET-7000 series User manual

ICP DAS USA

ICP DAS USA ET-7000 series User manual

ICP DAS USA PM-3033 Series User manual

ICP DAS USA

ICP DAS USA PM-3033 Series User manual

ICP DAS USA PDS-220F Series Use and care manual

ICP DAS USA

ICP DAS USA PDS-220F Series Use and care manual

ICP DAS USA ZT-2055 User manual

ICP DAS USA

ICP DAS USA ZT-2055 User manual

ICP DAS USA PET-AR400 User manual

ICP DAS USA

ICP DAS USA PET-AR400 User manual

ICP DAS USA SP-S2-DS User manual

ICP DAS USA

ICP DAS USA SP-S2-DS User manual

ICP DAS USA PET-7261 User manual

ICP DAS USA

ICP DAS USA PET-7261 User manual

ICP DAS USA I-7080 User manual

ICP DAS USA

ICP DAS USA I-7080 User manual

ICP DAS USA tM-AD5 User manual

ICP DAS USA

ICP DAS USA tM-AD5 User manual

ICP DAS USA ZT-2017 User manual

ICP DAS USA

ICP DAS USA ZT-2017 User manual

ICP DAS USA IR-310-RM User manual

ICP DAS USA

ICP DAS USA IR-310-RM User manual

ICP DAS USA WF-2051 User manual

ICP DAS USA

ICP DAS USA WF-2051 User manual

ICP DAS USA tET-P6 User manual

ICP DAS USA

ICP DAS USA tET-P6 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
1
Quick Start
For tM-AD4P2C2
August 2013, Version 1.00
Congratulations on purchasing the tM-AD4P2C2 the most popular automation
solution for remote monitoring and control applications. This Quick Start Guide will
provide information needed to get started with the tM-AD4P2C2. Please
also consult the User Manual for detailed information on the setup and use of the
tM-AD4P2C2.
In addition to this guide, the shipping box includes the following items:
tM-AD4P2C2
tM Series DIO User Manual
http://www.icpdas.com/root/product/solutions/datasheet/tm-series/tM-AD_Series_
User_Manual.pdf
tM-SERIES Website
http://www.icpdas.com/root/product/solutions/remote_io/rs-485/tm-series/tm-ad4p
2c2.html
ICP DAS Website
http://www.icpdas.com
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
2
1
-------
---------------------------------------------------------------------------
Understanding the Hardware Specifications
and Wiring Diagrams
Before installing the hardware, you should have a basic understanding of hardware
specification and the wiring diagrams.
System Specifications:
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
3
I/O Specifications:
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
4
Wire Connection:
Pin Assignment:
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
5
Make sure the switch placed in the
“Init” position.
3
----------------------------------------------------------------------------------
Connecting to the PC and the Power Supply
The tM-Series series is equipped with an RS-485
port for connection to a 232/USB converter to PC
2
--------------------------------------------
Booting the tM-AD4P2C2
in Init Mode
Connect to the PC
Using an RS-485 Converter
Connect to PC
Using a USB Converter
I
-
7520
Power Supply
RS
-
232
RS
-
485
PC
tM
-
Series
Power Supply
USB
RS
-
485
I
-
7561
PC
tM
-
Series
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
6
4
---------------------------------------------------------------------------------
Installing the DCON Utility
The DCON Utility is an easy-to-use tool designed to enable simple configuration of
I/O modules that use the DCON protocol.
Step 1: Locate the DCON Utility
The DCON Utility can be obtained from the companion from the
ICPDAS FTP site:
http://www.icpdas.com/download/7000/7000.htm
Step 2: Follow the prompts to complete the installation
After the installation has
been completed, there will be a
new shortcut to the DCON Utility on
the desktop.
5
---------------------------
-------------------------------------------------------
Using the DCON Utility to Initialize the
tM-AD4P2C2 Module
The tM-AD4P2C2 is an I/O module based on the DCON protocol, meaning that
you can use the DCON Utility to easily initialize it.
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
7
Step 1: Run the DCON Utility
Double-click the DCON Utility
shortcut on your desktop.
Step 2: Use the COM1 port to communicate with the
tM-AD4P2C2
Click the “COM Port” option from the menu and a dialog box will be displayed that
will allow you to set the communication parameters as described in the table below.
Communication
parameter Factory
default Value
Address 00
Baud Rate 9600
Protocol DCON
Checksum Disabled
Parity N,8,1
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
8
Step 3: Search for the
tM-AD4P2C2
module
Click “Start Search” button from the toolbox to search for the tM-AD4P2C2 module.
After the tM-AD4P2C2 module is displayed in the list, click “Stop Search” button.
Step 4: Connect to the tM-AD4P2C2
After clicking on the name of the module in the list, a dialog box will be displayed.
Start Search
Stop Search
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
9
Step 5: Initialize the tM-AD4P2C2 module
Set the “Address” field in the dialog box to 1 and then click “Setting” button to save
the settings.
Make sure the INIT switch is placed in the
“Normal” position.
7
----------------------------------------------------------------------------------
Starting the Module Operation
After rebooting the tM-AD4P2C2 module, search for the module to make sure the
settings have been changed. You can double click on the name of the module in
the list to open the configuration dialog box.
6
---------------------------------------
-----
Rebooting the
tM-AD4P2C2 Module in
Normal Mode
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
10
8
------------------------------------------------------
---------------------------
Modbus Address Mapping
Address Description Attribute
30001 ~ 30004
40001 ~ 40004 Analog input value of channel 0 to 3 R
30129 ~ 30130
40129 ~ 40130 Counter value of digital input channel 0 to 1 R
40257 ~ 40260 Analog input type code of channel 0 to 3 R/W
40225 ~ 40226 High alarm limit of channel 0 to 1 R/W
40233 ~ 40234 Low alarm limit of channel 0 to 1 R/W
40481 Firmware version (low word) R
40482 Firmware version (high word) R
40483 Module name (low word), 0x4001 R
40484 Module name (high word), 0x0722 R
40485 Module address, valid range: 1 ~ 247 R/W
40486 Bits 5:0
Baud rate, 0x03 ~ 0x0A
Code 0x03 0x04 0x05 0x06
Baud 1200 2400 4800 9600
Code 0x07 0x08 0x09 0x0A
Baud 19200 38400 57600 115200
Bits 7:6
00: no parity, 1 stop bit
01: no parity, 2 stop bits
10: even parity, 1 stop bit
11: odd parity, 1 stop bit
R/W
40488 Modbus response delay time in ms, valid range: 0 ~ 30
R/W
40489 Host watchdog timeout value, 0 ~ 255, in 0.1s R/W
40490 Channel enable/disable, 00h ~ 0Fh R/W
40492 Host watchdog timeout count, write 0 to clear R/W
00033 ~ 00034
10033 ~ 10034 Digital input value of channel 0 to 1 R
00065 ~ 00066
10065 ~ 10066 High latched value of DI R