tM-AD4P2C2 Quick Start Guide
1
Quick Start
For tM-AD4P2C2
August 2013, Version 1.00
Congratulations on purchasing the tM-AD4P2C2 the most popular automation
solution for remote monitoring and control applications. This Quick Start Guide will
provide information needed to get started with the tM-AD4P2C2. Please
also consult the User Manual for detailed information on the setup and use of the
tM-AD4P2C2.
In addition to this guide, the shipping box includes the following items:
tM-AD4P2C2
tM Series DIO User Manual
http://www.icpdas.com/root/product/solutions/datasheet/tm-series/tM-AD_Series_
User_Manual.pdf
tM-SERIES Website
http://www.icpdas.com/root/product/solutions/remote_io/rs-485/tm-series/tm-ad4p
2c2.html
ICP DAS Website
http://www.icpdas.com
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
2
1
-------
---------------------------------------------------------------------------
Understanding the Hardware Specifications
and Wiring Diagrams
Before installing the hardware, you should have a basic understanding of hardware
specification and the wiring diagrams.
System Specifications:
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
3
I/O Specifications:
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
4
Wire Connection:
Pin Assignment:
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
5
Make sure the switch placed in the
“Init” position.
3
----------------------------------------------------------------------------------
Connecting to the PC and the Power Supply
The tM-Series series is equipped with an RS-485
port for connection to a 232/USB converter to PC
2
--------------------------------------------
Booting the tM-AD4P2C2
in Init Mode
Connect to the PC
Using an RS-485 Converter
Connect to PC
Using a USB Converter
I
-
7520
Power Supply
RS
-
232
RS
-
485
PC
tM
-
Series
Power Supply
USB
RS
-
485
I
-
7561
PC
tM
-
Series
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
6
4
---------------------------------------------------------------------------------
Installing the DCON Utility
The DCON Utility is an easy-to-use tool designed to enable simple configuration of
I/O modules that use the DCON protocol.
Step 1: Locate the DCON Utility
The DCON Utility can be obtained from the companion from the
ICPDAS FTP site:
http://www.icpdas.com/download/7000/7000.htm
Step 2: Follow the prompts to complete the installation
After the installation has
been completed, there will be a
new shortcut to the DCON Utility on
the desktop.
5
---------------------------
-------------------------------------------------------
Using the DCON Utility to Initialize the
tM-AD4P2C2 Module
The tM-AD4P2C2 is an I/O module based on the DCON protocol, meaning that
you can use the DCON Utility to easily initialize it.
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
7
Step 1: Run the DCON Utility
Double-click the DCON Utility
shortcut on your desktop.
Step 2: Use the COM1 port to communicate with the
tM-AD4P2C2
Click the “COM Port” option from the menu and a dialog box will be displayed that
will allow you to set the communication parameters as described in the table below.
Communication
parameter Factory
default Value
Address 00
Baud Rate 9600
Protocol DCON
Checksum Disabled
Parity N,8,1
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
8
Step 3: Search for the
tM-AD4P2C2
module
Click “Start Search” button from the toolbox to search for the tM-AD4P2C2 module.
After the tM-AD4P2C2 module is displayed in the list, click “Stop Search” button.
Step 4: Connect to the tM-AD4P2C2
After clicking on the name of the module in the list, a dialog box will be displayed.
Start Search
Stop Search
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
9
Step 5: Initialize the tM-AD4P2C2 module
Set the “Address” field in the dialog box to 1 and then click “Setting” button to save
the settings.
Make sure the INIT switch is placed in the
“Normal” position.
7
----------------------------------------------------------------------------------
Starting the Module Operation
After rebooting the tM-AD4P2C2 module, search for the module to make sure the
settings have been changed. You can double click on the name of the module in
the list to open the configuration dialog box.
6
---------------------------------------
-----
Rebooting the
tM-AD4P2C2 Module in
Normal Mode
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
10
8
------------------------------------------------------
---------------------------
Modbus Address Mapping
Address Description Attribute
30001 ~ 30004
40001 ~ 40004 Analog input value of channel 0 to 3 R
30129 ~ 30130
40129 ~ 40130 Counter value of digital input channel 0 to 1 R
40257 ~ 40260 Analog input type code of channel 0 to 3 R/W
40225 ~ 40226 High alarm limit of channel 0 to 1 R/W
40233 ~ 40234 Low alarm limit of channel 0 to 1 R/W
40481 Firmware version (low word) R
40482 Firmware version (high word) R
40483 Module name (low word), 0x4001 R
40484 Module name (high word), 0x0722 R
40485 Module address, valid range: 1 ~ 247 R/W
40486 Bits 5:0
Baud rate, 0x03 ~ 0x0A
Code 0x03 0x04 0x05 0x06
Baud 1200 2400 4800 9600
Code 0x07 0x08 0x09 0x0A
Baud 19200 38400 57600 115200
Bits 7:6
00: no parity, 1 stop bit
01: no parity, 2 stop bits
10: even parity, 1 stop bit
11: odd parity, 1 stop bit
R/W
40488 Modbus response delay time in ms, valid range: 0 ~ 30
R/W
40489 Host watchdog timeout value, 0 ~ 255, in 0.1s R/W
40490 Channel enable/disable, 00h ~ 0Fh R/W
40492 Host watchdog timeout count, write 0 to clear R/W
00033 ~ 00034
10033 ~ 10034 Digital input value of channel 0 to 1 R
00065 ~ 00066
10065 ~ 10066 High latched value of DI R
ICP DAS CO., LTD.
Copyright © 2013 ICP DAS Co., Ltd.All Rights Reserved. E-mail: [email protected]
tM-AD4P2C2 Quick Start Guide
11
Address Description Attribute
00073 ~ 00074
10073 ~ 10074 High latched value of DO R
00097 ~ 00098
10097 ~ 10098 Low latched value of DI R
00105 ~ 00106
10105 ~ 10106 Low latched value of DO R
00225 ~ 00228
10225 ~ 10228
Over/under range status of analog input channel 0 to 3
for 4 ~ 20mA or 0 ~ 20mA ranges R
00001 ~ 00002 Digital output value of channel 0 to 1 R/W
00129 ~ 00130 Safe value of digital output channel 0 to 1 R/W
00161 ~ 00162 Power on value of digital output channel 0 to 1 R/W
00193 ~ 00194 Counter update trigger edge of digital input channel 0
to 1 R/W
00257 Protocol, 0: DCON, 1: Modbus RTU R/W
00258 Protocol, 0: determined by 00257, 1: ModbusASCII R/W
00260 Modbus host watchdog mode
0: same as I-7000
1: can use AO and DO command to clear host
watchdog timeout status
R/W
00261 1: enable, 0: disable host watchdog R/W
00264 Write 1 to clear latched DIO states W
00265 DI active state R/W
00266 DO active state R/W
00269 Modbus data format, 0: hex, 1: engineering R/W
00270 Host watch dog timeout status, write 1 to clear host
watch dog timeout status R/W
00271 1: enable, 0: disable fast mode R/W
00273 Reset status, 1: first read after powered on, 0: not the
first read after powered on R
00289 ~ 00290
Low alarm status of channel 0 to 1. Write 1 to clear low
latched alarm of channel 0 to 1 R/W
00305 ~ 00306 High alarm status of channel 0 to 1. Write 1 to clear
high latched alarm of channel 0 to 1 R/W
00321 ~ 00322 Enable/disable alarm of channel 0 to 1 R/W
00337 ~ 00338 Alarm type, momentary or latched, of channel 0 to 1 R/W
00513 ~ 00514 Write 1 to clear counter value of digital input channel 0
to 1 W

Other manuals for tM-AD4P2C2

1

Other ICP DAS USA Control Unit manuals

ICP DAS USA MDC-700 Series User manual

ICP DAS USA

ICP DAS USA MDC-700 Series User manual

ICP DAS USA M-7064 User manual

ICP DAS USA

ICP DAS USA M-7064 User manual

ICP DAS USA EIP-2000 Series User manual

ICP DAS USA

ICP DAS USA EIP-2000 Series User manual

ICP DAS USA M-7016 User manual

ICP DAS USA

ICP DAS USA M-7016 User manual

ICP DAS USA tM-AD5 User manual

ICP DAS USA

ICP DAS USA tM-AD5 User manual

ICP DAS USA ET-7065 User manual

ICP DAS USA

ICP DAS USA ET-7065 User manual

ICP DAS USA ECAT-2012H User manual

ICP DAS USA

ICP DAS USA ECAT-2012H User manual

ICP DAS USA LinPAC-51 Series User manual

ICP DAS USA

ICP DAS USA LinPAC-51 Series User manual

ICP DAS USA M-7028 User manual

ICP DAS USA

ICP DAS USA M-7028 User manual

ICP DAS USA GT-540P-3GWA-OEM1 User manual

ICP DAS USA

ICP DAS USA GT-540P-3GWA-OEM1 User manual

ICP DAS USA WISE-5801-MTCP User manual

ICP DAS USA

ICP DAS USA WISE-5801-MTCP User manual

ICP DAS USA ECAT-2051 User manual

ICP DAS USA

ICP DAS USA ECAT-2051 User manual

ICP DAS USA M-7067D User manual

ICP DAS USA

ICP DAS USA M-7067D User manual

ICP DAS USA tDS-700-T Series User manual

ICP DAS USA

ICP DAS USA tDS-700-T Series User manual

ICP DAS USA I-7080 User manual

ICP DAS USA

ICP DAS USA I-7080 User manual

ICP DAS USA ET-7015 User manual

ICP DAS USA

ICP DAS USA ET-7015 User manual

ICP DAS USA M-7067 User manual

ICP DAS USA

ICP DAS USA M-7067 User manual

ICP DAS USA PM-3033 Series User manual

ICP DAS USA

ICP DAS USA PM-3033 Series User manual

ICP DAS USA SG-785 User manual

ICP DAS USA

ICP DAS USA SG-785 User manual

ICP DAS USA I-7063D User manual

ICP DAS USA

ICP DAS USA I-7063D User manual

ICP DAS USA PDS-5000 Series User manual

ICP DAS USA

ICP DAS USA PDS-5000 Series User manual

ICP DAS USA ET-7218Z User manual

ICP DAS USA

ICP DAS USA ET-7218Z User manual

ICP DAS USA ET-2200 Series User manual

ICP DAS USA

ICP DAS USA ET-2200 Series User manual

ICP DAS USA PM-3133-RCT Series User manual

ICP DAS USA

ICP DAS USA PM-3133-RCT Series User manual

Popular Control Unit manuals by other brands

Honeywell TR80 Installation and operating guide

Honeywell

Honeywell TR80 Installation and operating guide

Argo-Hytos VPP2-06-xV/xx-CE1017 Instructions for use

Argo-Hytos

Argo-Hytos VPP2-06-xV/xx-CE1017 Instructions for use

Hella ONYX.CENTER quick start guide

Hella

Hella ONYX.CENTER quick start guide

Festo MSE6-C2M Operating	 instruction

Festo

Festo MSE6-C2M Operating instruction

Coelbo SPEEDMATIC SET Series Installation and operating instructions

Coelbo

Coelbo SPEEDMATIC SET Series Installation and operating instructions

SMC Networks VXF2 Series Operation manual

SMC Networks

SMC Networks VXF2 Series Operation manual

Beninca DA.24A operating instructions

Beninca

Beninca DA.24A operating instructions

Burkert 0280 operating instructions

Burkert

Burkert 0280 operating instructions

Texas Instruments TLC5540 user guide

Texas Instruments

Texas Instruments TLC5540 user guide

Lovato DCTL Series instruction manual

Lovato

Lovato DCTL Series instruction manual

Murphy Autostart AS705S Communications guide

Murphy

Murphy Autostart AS705S Communications guide

NXP Semiconductors Freescale MC9S12C32 user guide

NXP Semiconductors

NXP Semiconductors Freescale MC9S12C32 user guide

RADWAG MW-01 Series user manual

RADWAG

RADWAG MW-01 Series user manual

M-system M8CD1 instruction manual

M-system

M-system M8CD1 instruction manual

CCS PD2 Series Instruction guide

CCS

CCS PD2 Series Instruction guide

DITECH DT5638 instruction manual

DITECH

DITECH DT5638 instruction manual

ICM Controls ICM325HN Installation, operation & application guide

ICM Controls

ICM Controls ICM325HN Installation, operation & application guide

NeuLog WIFI-202 Guide

NeuLog

NeuLog WIFI-202 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.