11 12
Ranges & Accuracies:
AC Converter: 61-773,61-775modelsaretruermssensing.
Accuracy: Accuracyisspecifiedas+/-(apercentageofthereading+afixedcount)at
23°C±5°C(73.4°F±9°F),lessthan75%relativehumidity.
Temperature Coefficient:0.1timestheapplicableaccuracyspecificationperdegreeCfrom
0°Cto18°Cand28°Cto50°C(32°Fto64°Fand82°Fto122°F)
Function Rangeand
Resolution
Accuracy Input
Protection
61-773 61-775
ACCurrent10.0to999.9A
2.0%+5
(45Hzto60Hz)
2.0%+5
(20Hzto100Hz) 1000AAC
6.0%+5
(60Hzto400Hz)
6.0%+5
(100Hzto400Hz)
DCCurrent10.0to999.9A N/A 2.0%+5 1000ADC
(61-775only)
ACVoltage1,2
0.0to600.0V 1.0%+5
(45Hzto100Hz)
1.0%+5
(20Hzto100Hz)
1000VDC/
750VACRMS
600.0to750.0V 1.5%+5
(45Hzto100Hz)
1.5%+5
(45Hzto100Hz)
0.0to750.0V 6.0%+5
(100Hzto400Hz)
6.0%+5
(100Hzto400Hz)
DCVoltage20.0-600.0V 1.0%+5 1.0%+5 1000VDC/
750VACRMS
600.0to999.9V 1.5%+5 1.5%+5
Resistance30.0to999.9Ω1.5%+5 1.5%+5 600VDC/ACRMS
1000to9999Ω
Capacitance 0.0to999.9µF 5.0%+15 5.0%+15 600VDC/ACRMS
Continuity 0.0to999.9Ω
Audibleat<30
Responsetime
500mS
Audibleat<30
Responsetime
500mS 600VDC/ACRMS
Frequency420.0to400.0Hz 0.5%+5 0.5%+5 1000VDC/
750VACRMS
*Accuracystatedforcrestfactor≤1.5atfullscaleand≤3athalfscale.
PEAK:
1ForVAC/AAC/DC(45-65Hz)hasaccuracyof±(5%rdg+15digits);minimuminputforVAC>10VandforAAC/
DC>10A;responsetime>1ms.
2Inputimpedance:1MΩ.
3Opencircuitvoltage≈1.2VDC
4FrequencySensitivity:5VrmsonACVOLTSrange(≥5AACat20to100Hz)(≥10AACat100to400Hz),Frequency
can be measured through clamp head
Dispose of waste electrical and electronic equipment
Inordertopreserve,protectandimprovethequalityofenvironment,protecthumanhealth
andutilizenaturalresourcesprudentlyandrationally,theusershouldreturnunservice-
ableproducttorelevantfacilitiesinaccordancewithstatutoryregulations.Thecrossed-out
wheeled bin indicates the product needs to be disposed separately and not as municipal
waste.
Disposal of used batteries/accumulators!
Theuserislegallyobligedtoreturnusedbatteriesandaccumulators.Disposingusedbat-
teriesinthehouseholdwasteisprohibited!Batteries/accumulatorscontaininghazardous
substancesaremarkedwiththecrossed-outwheeledbin.Thesymbolindicatesthatthe
product is forbidden to be disposed via the domestic refuse. The chemical symbols for the
respectivehazardoussubstancesareCd=Cadmium,Hg=Mercury,Pb = Lead.
You can return used batteries/accumulators free of charge to any collecting point of your
localauthority,ourstores,orwherebatteries/accumulatorsaresold.Consequentlyyoucomplywith
your legal obligations and contribute to environmental protection.
Warranty Statement:
This tester is warranted to the original purchaser against defects in material and workmanship for
twoyearsfromthedateofpurchase.Duringthiswarrantyperiod,IDEALINDUSTRIES,INC.will,
at its option, replace or repair the defective unit, subject to verification of the defect or malfunction.
Thiswarrantydoesnotapplytodefectsresultingfromabuse,neglect,accident,unauthorizedrepair,
alteration, or unreasonable use of the instrument.
AnyimpliedwarrantiesarisingoutofthesaleofanIDEALproduct,includingbutnotlimited
to implied warranties of merchantability and fitness for a particular purpose, are limited to the
above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or
consequentialdamages,expenses,oreconomicloss,orforanyclaimorclaimsforsuchdamage,
expensesoreconomicloss.
Statelawsvary,sotheabovelimitationsorexclusionsmaynotapplytoyou.Thiswarrantygivesyou
specific legal rights, and you may also have other rights which vary from state to state.
Warrantydoesnotcoverbatteries.