Idemia MorphoAccess SIGMA Extreme Series User manual

Head office :
2, place Samuel de Champlain - 92400 Courbevoie
Detailed instructions are available at
Des instructions détaillées sont disponibles sur
El detalle de las instrucciones está disponible en
https://biometricdevices.idemia.com
Technical Support and Hotline
USA & Canada
Mail: support.bioterminals.us@idemia.com
Tel: +1 888 940 7477
LATAM (Latin America)
Mail: support.bioterminals.us@idemia.com
Tel: +1 714 575 2973
EMEA (Europe, Middle-East, Africa)
Mail: support.bioterminals@idemia.com
Tel: +33 1 30 20 30 40
APAC (Asia & Pacific)
Mail: support.bioterminals.in@idemia.com
Tel: +91 8929 159 665
India
Mail: support.bioterminals.in@idemia.com
Tel: +91 1800 120 203 020
COPYRIGHT © 2021, IDEMIA
Φ= 4mm
2
Φ= 4mm
1
Φ= 4mm
4
Φ= 4mm
3
Φ= 4mm
6
Φ= 4mm
5
207,00mm
97,50mm
82,00mm
Ø44,00mm
65,50mm
Scale 1.0
MorphoAccess®SIGMA Extreme Series
Quick Installation Guide
Quick
Guide
WEE E
293703596-F
Regulatory, safety and environmental notices
Products bearingthe CE marking comply withone or moreof the following
EUDirectives as may be applicable:
Low VoltageDirective 2006/95/EC.
EMC Directive 2004/108/EC.
R&TTE Directive 1999/5/EC.
Ecodesign Directive 2009/125/EC.
RoHS Directive 2011/65/EU.
Compliance with these directives is assessedusingapplicableEuropean
Harmonised Standards.
This symbol means Direct Current (DC)
Theinstallation of this product should be madeby a qualified service
Person and should comply with all local regulations.
It is strongly recommendedtousea class II power supply at 12VDC 1A
minimum or at 24VDC 500mA minimum in conformity with Safety Electrical
Low Voltage (SELV). Thepower supply cable lengthshould not exceed 10
meters.
This systemmust be installedin accordance with the National Electrical
Code (NFPA 70), and the localauthority having jurisdiction.
This product is intended to be installedwitha power supply complying with
IEC60950-1, inaccordance with theNECClass 2 requirements; or supplied
by alisted IEC60950-1 external Power Unit marked Class 2, Limited Power
source, or LPS and rated 12VDC, 1A minimum or 24VDC, 0,5A minimum.
In case of building-to-buildingconnection (power sourcein abuilding, and
terminal in another building), it is recommended to connect the 0V of the
power supply to theearthing system of thebuilding. And theterminal block
Power Groundmust be connected withthe earthing system of the other
building.
Note that allconnections of the MorphoAccess®SIGMA Extreme Series
terminal described hereafter are of SELV (Safety Electrical Low Voltage)
type.
This symbolmeans do not dispose of your product with your other
household waste. Instead, you should protect humanhealth and the
environment by handing over your wasteequipment to a designated
collection point for the recycling of waste electrical and electronic
equipment.
Models:
MorphoAccess® Sigma Extreme iClass (MPH-AC002B)
MorphoAccess® Sigma Extreme Multi (MPH-AC002B)
MorphoAccess® Sigma Extreme Prox (MPH-AC002A)
MorphoAccess® Sigma Extreme iClass FFD (MPH-AC002B)
MorphoAccess® Sigma Extreme Multi FFD (MPH-AC002B)
MorphoAccess® Sigma Extreme Prox FFD (MPH-AC002A)
Access
Control Line
Security
Destructive
Attack Endurance Stand-by
Power Conditions
Level I Level I Level IV Level I NA
UL294 Performance levels
Status LED Optional Wi-Fi™
Interface (plugged at
the back of the terminal)
USB host port
Biometric
sensor
5" WVGA
touchscreen
LCD
Camera
Microphone
Light Sensor
RF Card reader
Speaker
40mm min

Deployment Environments
Themanufacturer cannot be held responsible incase of non-compliance withthe
following recommendations or incorrect use of the terminal.
Repair and Accessories
Do not attempt to repair theMorphoAccess® SIGMA Extreme Series terminal
yourself. Themanufacturer cannot be held responsible for any damage/accident
that may result from attempts to repair components. Any work carried out by
non-authorized personnel will void your warranty.
Only use the terminal with its original accessories. Attempts to use unapproved
accessories with your terminalwill void your warranty.
Micro SD Card
Themicro SD cardis linked to the terminal: it shall not be transferred from one
product to another.
Date / Time synchronization
The MorphoAccess® SIGMA Extreme Series terminal clock has a +/- 10 ppm
typical time deviation at +25ºC (roughly +/- 1sec per day). At lower and higher
temperature, deviation may be greater (maximum : 8sec per 48 hours).
When the terminal is used for applications requiringhigh time precision, it is
strongly recommended to synchronize the terminal with an external clock.
Firmware release
To get the best of our technology, we recommend you to download and install
thelast firmware release. Please check our website.
Recommendations
WARNING: Cleaning & Disinfection precautions
To clean the terminal, a dry cloth is recommended, especially for the
biometric sensor.
To disinfect the terminal, moisten a non-abrasive wipe with the
disinfectant Windex® Multi-Surface (or similar product containing L-
Lactic acid) and wipe the device’s surfaceandleave the surface wet
with disinfectant for at least 5 minutes. Any other practices (hydrogen
peroxide, bleach, chlorine, soda, alcohol, quaternary ammonium etc)
permanently damage and/or negatively impact the performances of the
device.
!
1
4
5
6
4
2
7
!
!
3
1
3
12
127,8mm
275,8mm
IP65*
!
1
2
2T20
3
*IP65 : Indoor use only
Not evaluated by UL
General precautions
Do not exposethe terminal to extreme temperatures.
When the environment is very dry, avoid synthetic carpeting near the
MorphoAccess® SIGMA Extreme terminal, to reduce the risk of unwanted
electrostatic discharge.
Areas containing combustibles
Do not install the terminal in the vicinity of gas stations or any other installation
containing flammableor combustible gases or materials. Theterminal is not
designed to be intrinsically safe.
The terminal should be installed in controlled lighting conditions
Avoidbiometric sensor exposure to a blinking light.
Avoid direct exposure of the biometric sensor to sunlight or to UV lights.
-20° to +60 °C (-4°to 140°F)
Operatinghumidity
Storage temperature
Storage humidity
10 % < RH < 95% (non condensing)
- 25° to + 70 °C (-13° to 158°F)
5% < RH < 95 %
IP code IP65 rated
For UL 294 compliance, theproducts are ratedfor indoor use
Operatingtemperature
In exceptional circumstances of ambient temperature and sun exposure,
the screen may feel hot.
!
Wiring Overview
!WARNING: Power Supply from electrical source shall be switched off before starting
the installation.
Before proceeding, make sure that the person in
charge of installation and connections, is properly
connected to earth, in order to prevent
Electrostatic Discharges (ESD).
External Power supply: 12/24 VDC
(regulated and filtered) 1A min @12VDC or
500mA min @24VDC, IEC 60950-1 standard
compliant. A 12 Volts power supply compliant
with SIA's Wiegand standard will also be
suitable. If sharing power between devices,
each unit must receive 1A (e.g. twounits
would requirea 12 VDC, 2A supply).
For UL compliance the units shall be
powered via a class 2 output from a UL 294
power supply.
A battery backup or uninterrupted power
supply (UPS) with built-in surge protection
is recommended.
IDEMIA recommends usinga Gauge AWG20 for 12V power supply.
Thevoltage measuredon the product block connector of the terminal must be equal
to 12V-24V (-15% / +10%).
Thevoltage drop due tothe cable shall be takeninto account. Thetable below shows
themaximum voltage drop between the power source and the terminal, depending on
the length of the cable.
Power Over Ethernet (POE): power can
be provided throughRJ-45 connector
using a PSE (Power Sourcing
Equipment) IEEE802.3af or
IEEE802.3at type 1 compliant.
For UL compliance the units shall be
powered via a UL 294B PSE power
supply, rated 48VDC (-10%/+15%).
Theterminal is aClass 0 (15.4 W)
PD (PoweredDevice).
!WARNING: Under
powering may cause
memory and data
corruption; over powering
may cause hardware
damage. Both of these
situations will void the
warranty
Maximum drop voltage (V)
Gauge
AWG Diameter
(mm)at 1m at 5m at 10m
24
22
20 0.64
0.51
0.03
0.05
0.08
0.17
0.26
0.42
0.33
0.53
0.84
0.81
Relay output 30VDC, 1A.
Suitable for inductive and resistive
loads. Inductive load management
requires a parallel diode for a better
contact lifetime.
Tamper 30VDC, 100 mA (Resistive).
UL has not verified Wi-Fi Capabilities.
Ethernet connection is for supplemental use not UL evaluated.
For UL installations only Wiegand is to be used.
UL has not evaluated GPIO and RS422/485 communication.
Other manuals for MorphoAccess SIGMA Extreme Series
1
This manual suits for next models
8
Other Idemia Touch Terminal manuals
Popular Touch Terminal manuals by other brands

Applied Comfort
Applied Comfort NFWC Series Installation & operation manual

Wincor Nixdorf
Wincor Nixdorf BEETLE /S-II plus user manual

Rockwell Automation
Rockwell Automation Allen-Bradley 1790P-T8BV8V installation instructions

Positec
Positec POSiPal manual

Shenzhen Chainway ITS Co.
Shenzhen Chainway ITS Co. C4050-Q4 user manual

Swegon
Swegon TBLZ-4-75 instructions