MorphoTop Slim
Installation guide

2/11
CETE | Global R&D November 2017 | V1
CONTENTS
INTRODUCTION............................................................................................................................................... 3
RECOMMENDATIONS..................................................................................................................................... 3
General precautions .................................................................................................................................... 3
Cleaning precautions................................................................................................................................... 3
Warning......................................................................................................................................................... 3
SAFETY INSTRUCTIONS................................................................................................................................. 4
Europe information...................................................................................................................................... 4
Caution.......................................................................................................................................................... 4
USA information........................................................................................................................................... 4
Caution.......................................................................................................................................................... 4
GENERAL DESCRIPTION................................................................................................................................ 5
RECOMMENDED DEVICE INSTALLATION.................................................................................................... 6
TECHNICAL CHARACTERISTICS............................................................................................................... 8
Device Configuration................................................................................................................................... 8
Device Option (license containers)............................................................................................................ 8
Man Machine Interface................................................................................................................................. 8
Size and weight ............................................................................................................................................ 8
Power consumption..................................................................................................................................... 8
OPERATING CONDITIONS.............................................................................................................................. 8
SOFTWARE ENVIRONMENTS........................................................................................................................ 9
SUPPORT ....................................................................................................................................................... 11
Biometrics Terminals Hot Line................................................................................................................. 11
Customer Support Department ................................................................................................................ 11

3/11
CETE | Global R&D November 2017 | V1
INTRODUCTION
We thank you for choosing a fingerprint acquisition terminal from IDEMIA.
The MorphoTop Slim provides an effective solution for the fingerprint acquisition of 4 fingers
simultaneously, of two thumbs and of rolled fingers.
Among a range of alternative biometric technologies, the use of fingerprints has significant
advantages: each fingerprint constitutes an unalterable physical signature which develops
before birth and preserves until death.
The MorphoTop Slim stands out as a fast, precise, easy-to-use and ideal system for the
fingerprint acquisition applications.
The MorphoTop Slim has the following characteristics:
•High quality TFT sensor (500 PPI IQS Appendix F certified),
•Compact size for easy installation and fast integration,
•Intuitive and easy-to-use Interface,
•Open architecture, with dedicated applications implemented via the Morpho LiveScan
Software Development Kit and MorphoBop SDK.
To ensure the most effective use of your MorphoTop Slim, we recommend that you read this
Installation Guide thoroughly.
RECOMMENDATIONS
General precautions
•Do not put sharp hard object (such as but not limited to screw-driver, pen, USB
connector,..) on the acquisition area. MorphoTop Slim sensor is robust as a TFT screen can
be, so sharp objects could damage the sensor.
•Do not attempt to repair the MorphoTop Slim yourself. The manufacturer cannot be held
responsible for any damage/accident that may result from attempts to repair components. Any
work carried out by unauthorized staff will invalidate your warranty.
•Do not expose the MorphoTop Slim to extreme temperatures.
•Due to electrostatic discharge, and depending on the environment, synthetic carpet should be
avoided in areas where the MorphoTop Slim has been installed.
Cleaning precautions
MorphoTop Slim is designed with anti-Smudge coating, for easier clean purpose. Clean periodically
latent trace with a dry wipe dedicated to optic or TFT screen part; no hard water (acidic/alkaline/ type
of detergent solvent). If necessary use ethyl alcohol.
Warning
The manufacturer cannot be held responsible if the above recommendations are not followed or if the
MorphoTop Slim is incorrectly used.

4/11
CETE | Global R&D November 2017 | V1
SAFETY INSTRUCTIONS
This product is planned for being installed according to the EN/IEC 60950-1 (Ed3) and its amendments. The
power supply is carried out by the standard USB3 link of the PC with a nominal voltage of 5V DC (as shown
on the product label: 5V ).
Europe information
Hereby declares that the MorphoTop Slim has been tested and found compliant with the
following standards as required by the EMC Directive:
2014/30/EU Directive of the European parliament and of the council of 26
February 2014 on the harmonisation of the laws of the Member
States relating to electromagnetic compatibility
2011/65/EU Directive of the European Parliament and of the Council of 8 June
2011 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment
Caution
This product is a Class A device. In a residential environment, this device may cause
interference. In this case, the user is encouraged to try to correct the interference with
appropriated measures.
USA information
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Caution
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
Not suitable for hazardous areas.

5/11
CETE | Global R&D November 2017 | V1
GENERAL DESCRIPTION
Rolled acquisition area limitation for USB2
Acquisition surface
Acquisition type indicators
2 mounting holes for M3 screw
Acquisition Status indicators:
•Orange means harder pression
on related finger is requested
USB trapdoor, to be able to
change USB cable if necessary.
Tightening torque of associated
screws (*4): 0.2 Nm

6/11
CETE | Global R&D November 2017 | V1
RECOMMENDED DEVICE INSTALLATION
To optimize the ergonomic of Thumb acquisition, it is advised to set up the product a bit over the table (and
fixed on the table, thanks to the 2 mounting holes defined just before), as shown below:
Drawing to drill the table:

7/11
CETE | Global R&D November 2017 | V1
Use two M3 screws to maintain the product to the table. Choose a screw length = table
thickness + 3 to 5.5mm. Fix them gently without exceeding max force of 0.9 Nm, and with M3
washers (1,1 mm thickness +/-0,1 mm) between the terminal and the support

8/11
CETE | Global R&D November 2017 | V1
TECHNICAL CHARACTERISTICS
Device Configuration
MorphoTop Slim: Slap Finger Print scanner (4/4/2), at 500 ppi IQS Appendix F certified, with VERIF
license
MorphoTop Slim R: Rolled Finger Print acquisition added, with ROLLED license
Device Option (license containers)
TOP-SLIM_MORPHOPAK
: to use activeX MorphoPAK for camera acquisition
TOP-SLIM_CLASSIF
: Classification license
TOP-SLIM_WSQ
: WSQ license for fingerprint image compression algorithm export
TOP-SLIM_BCL
: Basic Compression Library license
Man Machine Interface
Two-colored LEDs & Buzzer
Acquisition area 3’’x3.2’’
Size and weight
Volume (L*W*H) = 14,5 x 13 x 2,6 cm
3
(5.7x5.1x1”)
Weight = 0.4 Kg
Power consumption
Operating (acquisition) Typical: Vbus = 5.0V, I < 600 mA => P< 3 W
Idle (backlight switched off) Typical: Vbus = 5.0V, I = 410 mA => P= 2 W
Suspend (USB link closed) I < 2,5 mA
OPERATING CONDITIONS
Operating Temperature: 0°C to +50°C.
Relative Humidity:10%<RH<80%.
Storage -40°C to +70°C.
RH < 90%.
Light We recommend the MorphoTop Slim installation within controlled lighting
conditions (300-1500 Lux). Avoid direct exposure of sensor to sunlight or
intensive UV lights. Both may degrade the performances of the sensor on a
long time period (even when device not powered).
Ground connection Make sure that the ground connection of your computer is correctly done
(connected to earth), otherwise terminal might be sensible to electric noise

9/11
CETE | Global R&D November 2017 | V1
SOFTWARE ENVIRONMENTS
Windows 7, 8.1,10 (32 & 64 bit)
Linux Ubuntu 14.04 & 16.04 (32 & 64 bit)
Nominal PC HW configuration is I5 Core with 4 GB RAM
DRIVER INSTALLATION
Before the first use, please follow the guideline hereunder:
•Launch the driver install
•Once the driver is installed, plug MorphoTop Slim to the computer directly (No USB hub).
•Validate the driver activation.
•You can now launch the MorphoLiveScan SDK (refer to its installation guide for proper usage).
USB REQUIREMENT
It is absolutely mandatory to have a dedicated USB controller for the MorphoTop Slim. It means that no other
USB device should be plugged on the same controller, especially high load devices such as hard disk or
webcam, or another MorphoTOP device
It is highly recommended to plug MorphoTop Slim on a USB3 port. USB2 port could be not enough for full
efficiency of MorphoTop Slim device. You can plug MorphoTop Slim on one USB2 port if it has high power
(0,7 A instead of 500mA for nominal port). Using USB2 port will have lower image frame rate and will limit
the active area for rolled* finger acquisition.
*: Rolled function available on MorphoTop Slim R version only
In order to check if the computer includes enough USB controller, please follow these instructions:
In the Windows device manager, you will be able to check the USB controller list:
Click on the “Start” Button
Choose: “control panel”
Choose “system”
Click on the tab “Device”
Click on “Device Manager”
Check USB controller

10/11
CETE | Global R&D November 2017 | V1
Then, you will be able to count USB controller on your computer. It is highly recommended to have at least 2
controllers:
-1 for MorphoTop Slim
-1 for other devices behind a USB Hub

11/11
CETE | Global R&D November 2017 | V1
SUPPORT
Biometrics Terminals Hot Line
To access this service from Biometric Terminals Business Unit, please send an email rather
than call the hot line.
Phone: + 33 1 30 20 30 40
Web site: http://www.biometric-terminals.com/
Produced by IDEMIA Identity & Security France
Registered office:
Adresse : 11 boulevard Galliéni
92130 Issy-les-Moulineaux
FRANCE Support
For Products sold by other Business Units, please contact your sales / program interface to
have support procedure.
Customer Support Department
IDEMIA Identity & Security France
SAV Terminaux Biométriques
Boulevard Lénine - BP428
76805 Saint Etienne du Rouvray
FRANCE
Tel: +33 2 35 64 55 05
Copyright ©2017 IDEMIA
www.idemia.com
Table of contents
Other Idemia Touch Terminal manuals