Input / Output (FB3) Freedom Bridge™
Installation Guide
PART NUMBERS 50-40-I/O, 50-40-I/OL
Replaces 50-40-3
50-24-I/O
Replaces 50-24-3
PHYSICAL SPECIFICATIONS
Length 76 mm (3.00 in.)
Width 47 mm (1.85 in.)
Height 17 mm (0.67 in.)
Weight 34 g (1.20 oz.)
Max Readers 0
Max Input 12
Max Output 2
Certications
Electrical: UL294 and UL294B
Power over ethernet: IEEE 802af
Mode A only, Class 2 (6.49 Watts)
EMI Radiation: FCC Part 15 Class B
SUMMARIZED LEVELS OF
ACCESS CONTROL COMPONENTS
Destructive Attack Level I
Line Security Level I
Endurance Level I
Standby Power Level I
Single Point Locking Level I
BASE PLATE MOUNTING
Dimension Millimeters Inches
A116.07 4.57
B78.74 3.10
C15.24 0.60
D85.59 3.37
E10.16 0.40
F58.42 2.30
E
D
A
C
BF
Freedom Bridges should only be installed in dry, non-condensing
environments. The ambient temperature of the environment should
range between -40°C and 50°C.
Freedom Encryption Bridges should only be mounted to non-conductive
surfaces. Incorrect mounting may short-circuit the electronics, which will
cause it to malfunction.
DC power, reader, input contact, and output device wires should
be between 16-28 AWG. They should also be stripped 5.5mm to
sufciently t the terminal blocks and ensure that they do not come in
contact with each other.
INSTALLATION REQUIREMENTS
For each of the following steps, be sure to reference the wiring
diagram on page 2 for additional details:
1. If you have any supervised input contacts, wire them to the Digital
Contact Inputs using Method 1 or Method 2. Note: Only In5, In6,
In11, and In12 support Input Supervision.
2. If you have any non-supervised input contacts, wire them to the
Digital Contact Inputs.
3. Wire the output devices to the Relay Outputs.
4. Supply power to the Freedom Bridge using either or both of the
following methods:
A. A 2.25 – 5.25W Power over Ethernet (PoE) port on an
Ethernet switch connected to the Freedom Bridge using
a Cat5e or Cat6 cable. (Passive injectors not supported;
Mode A PoE only)
B. 12 – 16Vdc & 350mA (300mA external & 50 mA internal)
DC power connected directly to the TB1 terminal on the
Freedom Bridge.
5. If you are not using PoE to power your Freedom Bridge, connect
a Cat5e or Cat6 cable from any port on an Ethernet Switch to
the RJ-45 connector on the Freedom Bridge. Note: Ethernet only
supports a maximum cable length of 100 m.
6. To congure and add the Freedom Bridge to a MESH/Freedom
Server, refer to the MESH/Freedom Solution Guide manual.
INSTALLATION PROCEDURE
INSTALLATION GUIDE
TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE.
REVISION DATE: 2020-06-02
Identiv (NASDAQ: INVE) is a global provider of physical security and secure identication. Identiv’s products, software, systems, and
services address the markets for physical and logical access control, video analytics and a wide range of RFID-enabled applications.
For more information, visit identiv.com or email sales@identiv.com.
© Identiv, Inc. | All rights reserved. This document is Identiv public information.
Wiring Reference
OPTIONAL DC POWER IN
0v DC Power Ground
+12 DC Power Input
Requirements
• 12 – 16 Vdc
• 350 mA
(300 mA external & 50 mA internal)
1
DIGITAL CONTACT INPUTS
0v / R# Ground
12v Power output
In1 - In12 Input 1 - 12
12v Power
Output using
PoE
• 11.5 - 12.5 Vdc
• 300 mA Max. Current
12v Power
Output using
DC
• 8.5 - 16 Vdc
• 300 mA Max. Current
*Only In5, In6, In11, and In12 support Input Supervision
4
RELAY OUTPUTS
Nc Normally closed
C1 - C2 Common 1 - 2
No Normally open
Relay Contact DC: 30 Vdc @ 1 Adc
AC: 60 Vac @ 0.5 Aac
3
2
Press and hold this button for 10 seconds to
reset the conguration back to default.
RESET BUTTON
This product is sensitive to Electrostatic Discharges (ESD).
Take precautions while handling the product by using proper grounding straps at all times.
CAUTION
NOTE
As long as the total current of the reader plus a door strike DOES NOT EXCEED 300mA,
you may power the door strike using the power out and ground from the reader Input terminal block.
A ashing green “Ready” LED light on
the Freedom Bridge circuit board indicates
that the bridge is powered but not
connected to a server.
A solid green “Ready” LED light indicates
that the Freedom Bridge has established a
connection to the server and is ready to use.

This manual suits for next models

3

Other Identiv IP Access Controllers manuals

Identiv MobilisID Assembly instructions

Identiv

Identiv MobilisID Assembly instructions

Identiv uTrust TouchSecure Wall Mount User manual

Identiv

Identiv uTrust TouchSecure Wall Mount User manual

Identiv ENTERPHONE MESH 19 User manual

Identiv

Identiv ENTERPHONE MESH 19 User manual

Popular IP Access Controllers manuals by other brands

SIB TF1 user manual

SIB

SIB TF1 user manual

JWS DWPS102U quick start guide

JWS

JWS DWPS102U quick start guide

FingerTec Keylock 8800 quick start guide

FingerTec

FingerTec Keylock 8800 quick start guide

Savi SaviTag 600 Series installation guide

Savi

Savi SaviTag 600 Series installation guide

Roger MCT12M operating manual

Roger

Roger MCT12M operating manual

Linear AP-3 installation instructions

Linear

Linear AP-3 installation instructions

Altronix ACMCB Series installation guide

Altronix

Altronix ACMCB Series installation guide

H3C WBC580 G2 Installation, quick start

H3C

H3C WBC580 G2 Installation, quick start

Navkom ARX-manager user manual

Navkom

Navkom ARX-manager user manual

Controlsoft SOLO CS-AC-3210 installation instructions

Controlsoft

Controlsoft SOLO CS-AC-3210 installation instructions

Soyal AR-721H manual

Soyal

Soyal AR-721H manual

U-Prox IP500 installation manual

U-Prox

U-Prox IP500 installation manual

Command access MLRK1 Series Insert Instructions

Command access

Command access MLRK1 Series Insert Instructions

KAS KSS-320-FK user guide

KAS

KAS KSS-320-FK user guide

ZKTeco X8-BT user manual

ZKTeco

ZKTeco X8-BT user manual

Rosslare AC-020 Hardware installation and user's guide

Rosslare

Rosslare AC-020 Hardware installation and user's guide

Matrix COSEC ATOM RD300 Quick installation guide

Matrix

Matrix COSEC ATOM RD300 Quick installation guide

Schlage MT20 user guide

Schlage

Schlage MT20 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.