IDS IDS805 User manual

IDS$805$Quick$User$Manual$700-266-07A$Issued$January$2015$
IDS805'Alarm'Panel'Quick'Start'Guide$
THANK'YOU'FOR'CHOOSING'IDS'TO'PROTECT'YOU'
Congratulations$on$your$purchase$of$an$IDS805$alarm$panel.$IDS$
alarm$panels$are$powerful,$versatile$and$highly$configurable$
security$systems,$which$should$be$installed$by$a$professionally$
trained$installer.$$
This$Quick$Start$Guide$covers$basic$user$functionality$to$get$you$
familiar$and$using$the$system$as$quickly$as$possible.$The$majority$of$
panel$features$are$programmable$only$by$an$IDS-accredited$
installer$in$possession$of$the$INSTALLER$CODE,$and$are$identified$
with$this$symbol@.$$
Advanced$User$Functions,$are$covered$in$the$Advanced$User$
Manual,$available$at$www.idsprotect.com.$
UNDERSTANDING'ALARM'PANEL'FUNCTIONS'
When$powered$up,$the$panel$is$either$ARMED$or$DISARMED.$
If$DISARMED,$it$is$READY$or$NOT$READY.$
Entering$data$confirm$by$Pressing$[*]$$
[#]$to$exit$programming$/$menu$or$to$clear$data$
Successful$data$entry$–$single$extendedkeypad$beep$
Failed$entry$–$triple$keypad$beep$
EMERGENCY'ALARMS'
Emergency$alarms$can$be$triggered:$
- on$the$keypad$by$holding$down$[F]$for$fire,$[P]$for$panic,$or$
[M]$for$medical$keys$
- Via$Fixed$Panic$Buttons$installed$by$the$alarm$installer,$or$
- Via$an$IDS$remote$transmitter,$holding$down$any$button$for$3$
seconds$or$a$dedicated$button.$(Please$confirm$with$installer)$
ARMINGand'DISARMING'YOUR'ALARM'
The$IDS805$panel$provides$multiple$arming$methods$and$modes$to$
suit$your$lifestyle.$$
AWAY'ARM'
Use$AWAY$ARM$when$you$are$leaving$the$premises$and$want$all$
entry$/$exit$zones$to$function$as$such.$
To$away$arm:$
1. Enter$USER$CODE$or$hold$down$[1]$until$keypad$beeps$
2. Exit$premises$before$exit$delay$beep$sequence$completes$
$
STAY'ARM'
Use$STAY$ARM$when$you$are$in$the$premises$and$want$some$zones$
armed$and$others$not$
1. Select$your$stay$profile,$if$there$are$more$than$one$and$the$last$
profile$selected$is$not$the$profile$you$want$to$stay$arm$in.$$
Press$[MODE]$then$[9]$[PROFILE$NUMBER]$[*]$
2. Hold$the$[5]$key$until$the$beep.$$
STAY'&'GO'ARM'
Use$STAY$AND$GO$when$some$people$are$leaving$the$premises,$
others$are$remaining$at$home.$Will$arm$in$the$last$stay$profile$
selected$if$not$changed.$
1. Hold$[6]$until$BEEP$
2. Exit$premises$before$exit$delay$beep$sequence$completes$
DISARM'
1. Enter$through$nominated$entry$zones$
2. Enter$USER$CODE$before$count$down$is$complete$
REMOTE'ARM'/'DISARM'
Use$your$remote$transmitter$to$arm$/$disarm$by$pressing$the$
programmed$button$
WORKING'WITH'ZONES'
BYPASS'A'ZONE'
Bypass$a$zone$to$prevent$it$triggering$an$alarm$when$armed$
1. Confirm$panel$is$DISARMED$
2. Press$[*][ZONE$NO],$[*][ZONE$NO]…[#]$
CHIME'ZONES'
The$keypad$will$chime$when$a$CHIME$ZONE$is$violated$while$the$
panel$is$DISARMED$
1. Hold$[2]$until$BEEP,$[ZONE$NO]$[*]….[#]$
VIEWING'PANEL'INFORMATION'
VIEW'ALARM'MEMORY'
View$zones$that$were$violated,$bypassed$or$tampered$during$the$
last$arm$cycle$
1. If$ARM$LED$is$flashing$before$disarming,$there$are$events$in$
ALARM$MEMORY$
2. Confirm$panel$is$DISARMED$
3. Hold$[0]$till$beep$
4. Press$[1]$[*]$to$view$bypassed$zones$
5. Press$[2]$[*]$to$view$tampered$zones$
Note:$ALARM$MEMORY$is$cleared$with$next$ARM$cycle$
WORKING'WITH'STAY'PROFILES'
STAY$PROFILES$enable$a$user$to$ARM$while$bypassing$programmed$
zones.$This$is$useful$when$users$are$in$the$premises,$but$want$
some$zones$armed.$
CREATE'STAY'ZONES'
STAY$ZONES$are$automatically$bypassed$when$a$panel$is$STAY$
ARMED.$STAY$ZONES$are$allocated$to$one$of$two$STAY$PROFILES.$$
1. Select$the$desired$STAY$PROFILE.$Press$[MODE]$then$[9]$
[PROFILE$NUMBER]$[*]$
2. Allocate$STAY$ZONE.$Hold$[3]$until$BEEP,$ZONE$NO…$[#]$
CREATE'BUZZ'ZONES'
BUZZ$zones$give$USERS$warning$of$a$zone$being$violation$before$
reporting$an$ALARM$to$the$control$room.$The$keypad$will$BEEP$for$
30$seconds$if$a$BUZZ$zone$is$violated$while$the$panel$is$STAY$
ARMED.$If$a$valid$USER$CODE$is$not$entered$in$this$period,$an$alarm$
status$will$be$reported$to$the$control$room.$
1. Hold$[4]$until$BEEP,$ZONE$NO$[*]…[#]$
Note:$A$zone$cannot$be$a$buzz$zone$and$a$stay$zone$
CODES'
OVERVIEW'OF'CODES'
The$IDS805$Panel$supports$multiple$types$of$CODES,$allowing$for$
flexibility$in$use:$
There$are$four$different$types$of$USER$CODES:$
MASTER'CODE,$code$1,$enables$its$owner$to$program$certain$user$
functions$
USER'CODES,$codes$2$to$13,$allow$users$to$ARM$/$DISARM$and$
carry$out$other$basic$functionality$on$the$system$
Maid’s'CODE,$code$14,$allows$the$system$to$be$disarmed$by$this$
code$if$the$system$was$armed$with$the$maid’s$code$
Duress'CODE,$code$15,$sends$a$duress$signal$to$the$monitoring$
company$if$used$to$arm$or$disarm$the$system$
ADD'or'CHANGE'USER'CODE'
1. Hold$[*]$till$BEEP,$then$[MASTER$CODE]$[*]$[USER$No.]$[*]$
[NEW$CODE]$[*],[USER$No.]$[*]$[NEW$CODE]$[*]...$continue$
until$all$codes$are$entered$then$[#]$to$exit$
Note:$User$No.$1$=$Master$Code,$No.$14$=$Maid’s$Code$and$No.$15$
=$Duress$Code$
$

IDS$805$Quick$User$Manual$700-266-07A$Issued$January$2015$
DELETE'USER'CODE'
1. Hold$[*]$till$BEEP,$then$[MASTER$CODE]$[*]$[USER$No.]$[*]$[*]$
Programming'the'IDS'Analog'Remote'Receiver'
The$IDS$Analog$Remote$Receiver$MKII$is$a$433.92$MHz$RF$receiver$
that$ is$ designed$ to$ connect$ to$ an$ Alarm$ Panel.$ The$ receiver$
connects$to$the$keypad$bus$(via$CLK$and$DAT$terminals),$permitting$
the$ Alarm$ Panel$ to$ be$ armed$ and$ disarmed$ from$ remote$
transmitters.$ When$ remotes$ are$ learned,$ they$ are$ assigned$ to$
USER$ CODES$ stored$ in$ the$ IDS$ Alarm$ Panel.$ This$ means$ that$ the$
Alarm$Panel$is$able$to$log$ARM/DISARM$events$per$user.$
Fig$1:$Remote$Receiver$
$
$
$
$
$
$
$
Adding'a'remote'to'the'remote'receiver'
There$are$two$steps$to$adding$a$remote$transmitter$to$the$IDS805.$
The$first$is$to$put$the$remote$receiver$into$learn$mode$and$the$
second$is$to$put$the$IDS805$into$add$user$mode.$
Remote$Receiver$
1. Put$dipswitch$3$on$the$remote$receiver$ON.$(Fig$1)$
IDS805$Alarm$
1. Hold$[*]$till$BEEP$
2. Enter$[MASTER$CODE]$[*]$$
3. Enter$[USER$No.]$[*]$$
4. Enter$[4$Digit$CODE]$[*]$
5. Press$and$hold$a$button$on$the$remote$transmitter$until$the$
keypad$beeps$
6. When$complete$press$[#]$
7. Put$dip$switch$down$
$
$
$
$
Trouble'Conditions'
If$the$POWER$LED$is$flashing$(or$if$so$programmed,$the$keypad$is$
beeping)$hold$down$the$[7]$key$for$one$second$to$see$which$zone$
indicator$is$on.$
Indicator$
Trouble$Condition$
2$
Failure$to$communicate$to$monitoring$company$
3$
Mains$power$failure$
4$
Low$battery$
5$
The$Telephone$line$has$been$cut$or$is$not$present$
6$
The$siren$wire$has$been$cut$or$the$fuse$has$blown$
7$
Keypad$has$experienced$a$tamper$
8$
Installers$code$must$be$entered$to$clear$an$alarm$
condition$
Note:$If$the$trouble$has$been$fixed$pressing$the$[#]$key$within$5$
seconds$of$entering$the$trouble$view$will$clear$the$trouble$
condition$indicator$
Issues'when'arming'
Before$you$call$for$your$installer$please$verify$the$following:$
Is'the'READY'Indicator'on?'
If$this$indicator$is$not$on,$one$or$more$zones$are$violated.$A$
flashing$zone$indicator$shows$a$violation.$Ensure$that$all$
monitored$doors$and$windows$are$closed.$Bypassing$a$violated$
zone$will$also$create$a$READY$condition.$
Does'the'siren'sound'before'you'exit?'
The$exit$delay$may$be$too$short$-$ask$your$installer$to$adjust$
the$exit$delay.$
OR$
You$have$not$left$via$a$Follower$and$Entry/Exit$zone$or$have$
strayed$into$an$Instant$zone.$Either$avoid$these$zones$or$ask$
your$installer$to$change$the$zone$type.$
Issues'when'disarming'
Does'the'siren'sound'immediately'upon'entry?'
You$have$not$entered$via$the$Entry/Exit$zone$or$have$strayed$
into$an$Instant$zone.$
Does'the'siren'sound'before'you'get'to'the'keypad?'
You$have$strayed$into$a$non-follower$zone$
OR$
You$have$taken$too$long$to$get$to$the$keypad.$
The'panel'will'not'disarm.'
You$may$have$entered$an$incorrect$code.$
Press$the$[#]$key$first,$then$re-enter$your$user$code.$
IMPORTANT'INFORMATION'
- Alarm$Panels$are$not$infallible$
- The$quality$of$installation$of$your$panel$will$determine$its$
effectiveness.$Ensure$that$your$panel$has$been$installed$by$an$
IDS-accredited$installer$
- Do$not$access$or$program$locations$reserved$for$professional$
installers$as$this$might$compromise$your$installation$
- Test$the$system$regularly$$
ZONE'INFORMATION'
$
Zone$
Location/Function$
1$
$
2$
$
3$
$
4$
$
5$
$
6$
$
7$
$
8$
$
$
INFORMATION'
$
Date$Installed$
$
$
$
Installer$Name$
$
Company$Name$
$
Contact$Details$
$
$
$
Security$Company$
$
Control$Room$Number$
$
$
$
Dip$Switches$
Other manuals for IDS805