IDS$805$Quick$User$Manual$700-266-07A$Issued$January$2015$
IDS805'Alarm'Panel'Quick'Start'Guide$
THANK'YOU'FOR'CHOOSING'IDS'TO'PROTECT'YOU'
Congratulations$on$your$purchase$of$an$IDS805$alarm$panel.$IDS$
alarm$panels$are$powerful,$versatile$and$highly$configurable$
security$systems,$which$should$be$installed$by$a$professionally$
trained$installer.$$
This$Quick$Start$Guide$covers$basic$user$functionality$to$get$you$
familiar$and$using$the$system$as$quickly$as$possible.$The$majority$of$
panel$features$are$programmable$only$by$an$IDS-accredited$
installer$in$possession$of$the$INSTALLER$CODE,$and$are$identified$
with$this$symbol@.$$
Advanced$User$Functions,$are$covered$in$the$Advanced$User$
Manual,$available$at$www.idsprotect.com.$
UNDERSTANDING'ALARM'PANEL'FUNCTIONS'
When$powered$up,$the$panel$is$either$ARMED$or$DISARMED.$
If$DISARMED,$it$is$READY$or$NOT$READY.$
Entering$data$confirm$by$Pressing$[*]$$
[#]$to$exit$programming$/$menu$or$to$clear$data$
Successful$data$entry$–$single$extendedkeypad$beep$
Failed$entry$–$triple$keypad$beep$
EMERGENCY'ALARMS'
Emergency$alarms$can$be$triggered:$
- on$the$keypad$by$holding$down$[F]$for$fire,$[P]$for$panic,$or$
[M]$for$medical$keys$
- Via$Fixed$Panic$Buttons$installed$by$the$alarm$installer,$or$
- Via$an$IDS$remote$transmitter,$holding$down$any$button$for$3$
seconds$or$a$dedicated$button.$(Please$confirm$with$installer)$
ARMINGand'DISARMING'YOUR'ALARM'
The$IDS805$panel$provides$multiple$arming$methods$and$modes$to$
suit$your$lifestyle.$$
AWAY'ARM'
Use$AWAY$ARM$when$you$are$leaving$the$premises$and$want$all$
entry$/$exit$zones$to$function$as$such.$
To$away$arm:$
1. Enter$USER$CODE$or$hold$down$[1]$until$keypad$beeps$
2. Exit$premises$before$exit$delay$beep$sequence$completes$
$
STAY'ARM'
Use$STAY$ARM$when$you$are$in$the$premises$and$want$some$zones$
armed$and$others$not$
1. Select$your$stay$profile,$if$there$are$more$than$one$and$the$last$
profile$selected$is$not$the$profile$you$want$to$stay$arm$in.$$
Press$[MODE]$then$[9]$[PROFILE$NUMBER]$[*]$
2. Hold$the$[5]$key$until$the$beep.$$
STAY'&'GO'ARM'
Use$STAY$AND$GO$when$some$people$are$leaving$the$premises,$
others$are$remaining$at$home.$Will$arm$in$the$last$stay$profile$
selected$if$not$changed.$
1. Hold$[6]$until$BEEP$
2. Exit$premises$before$exit$delay$beep$sequence$completes$
DISARM'
1. Enter$through$nominated$entry$zones$
2. Enter$USER$CODE$before$count$down$is$complete$
REMOTE'ARM'/'DISARM'
Use$your$remote$transmitter$to$arm$/$disarm$by$pressing$the$
programmed$button$
WORKING'WITH'ZONES'
BYPASS'A'ZONE'
Bypass$a$zone$to$prevent$it$triggering$an$alarm$when$armed$
1. Confirm$panel$is$DISARMED$
2. Press$[*][ZONE$NO],$[*][ZONE$NO]…[#]$
CHIME'ZONES'
The$keypad$will$chime$when$a$CHIME$ZONE$is$violated$while$the$
panel$is$DISARMED$
1. Hold$[2]$until$BEEP,$[ZONE$NO]$[*]….[#]$
VIEWING'PANEL'INFORMATION'
VIEW'ALARM'MEMORY'
View$zones$that$were$violated,$bypassed$or$tampered$during$the$
last$arm$cycle$
1. If$ARM$LED$is$flashing$before$disarming,$there$are$events$in$
ALARM$MEMORY$
2. Confirm$panel$is$DISARMED$
3. Hold$[0]$till$beep$
4. Press$[1]$[*]$to$view$bypassed$zones$
5. Press$[2]$[*]$to$view$tampered$zones$
Note:$ALARM$MEMORY$is$cleared$with$next$ARM$cycle$
WORKING'WITH'STAY'PROFILES'
STAY$PROFILES$enable$a$user$to$ARM$while$bypassing$programmed$
zones.$This$is$useful$when$users$are$in$the$premises,$but$want$
some$zones$armed.$
CREATE'STAY'ZONES'
STAY$ZONES$are$automatically$bypassed$when$a$panel$is$STAY$
ARMED.$STAY$ZONES$are$allocated$to$one$of$two$STAY$PROFILES.$$
1. Select$the$desired$STAY$PROFILE.$Press$[MODE]$then$[9]$
[PROFILE$NUMBER]$[*]$
2. Allocate$STAY$ZONE.$Hold$[3]$until$BEEP,$ZONE$NO…$[#]$
CREATE'BUZZ'ZONES'
BUZZ$zones$give$USERS$warning$of$a$zone$being$violation$before$
reporting$an$ALARM$to$the$control$room.$The$keypad$will$BEEP$for$
30$seconds$if$a$BUZZ$zone$is$violated$while$the$panel$is$STAY$
ARMED.$If$a$valid$USER$CODE$is$not$entered$in$this$period,$an$alarm$
status$will$be$reported$to$the$control$room.$
1. Hold$[4]$until$BEEP,$ZONE$NO$[*]…[#]$
Note:$A$zone$cannot$be$a$buzz$zone$and$a$stay$zone$
CODES'
OVERVIEW'OF'CODES'
The$IDS805$Panel$supports$multiple$types$of$CODES,$allowing$for$
flexibility$in$use:$
There$are$four$different$types$of$USER$CODES:$
MASTER'CODE,$code$1,$enables$its$owner$to$program$certain$user$
functions$
USER'CODES,$codes$2$to$13,$allow$users$to$ARM$/$DISARM$and$
carry$out$other$basic$functionality$on$the$system$
Maid’s'CODE,$code$14,$allows$the$system$to$be$disarmed$by$this$
code$if$the$system$was$armed$with$the$maid’s$code$
Duress'CODE,$code$15,$sends$a$duress$signal$to$the$monitoring$
company$if$used$to$arm$or$disarm$the$system$
ADD'or'CHANGE'USER'CODE'
1. Hold$[*]$till$BEEP,$then$[MASTER$CODE]$[*]$[USER$No.]$[*]$
[NEW$CODE]$[*],[USER$No.]$[*]$[NEW$CODE]$[*]...$continue$
until$all$codes$are$entered$then$[#]$to$exit$
Note:$User$No.$1$=$Master$Code,$No.$14$=$Maid’s$Code$and$No.$15$
=$Duress$Code$
$
IDS$805$Quick$User$Manual$700-266-07A$Issued$January$2015$
DELETE'USER'CODE'
1. Hold$[*]$till$BEEP,$then$[MASTER$CODE]$[*]$[USER$No.]$[*]$[*]$
Programming'the'IDS'Analog'Remote'Receiver'
The$IDS$Analog$Remote$Receiver$MKII$is$a$433.92$MHz$RF$receiver$
that$ is$ designed$ to$ connect$ to$ an$ Alarm$ Panel.$ The$ receiver$
connects$to$the$keypad$bus$(via$CLK$and$DAT$terminals),$permitting$
the$ Alarm$ Panel$ to$ be$ armed$ and$ disarmed$ from$ remote$
transmitters.$ When$ remotes$ are$ learned,$ they$ are$ assigned$ to$
USER$ CODES$ stored$ in$ the$ IDS$ Alarm$ Panel.$ This$ means$ that$ the$
Alarm$Panel$is$able$to$log$ARM/DISARM$events$per$user.$
Fig$1:$Remote$Receiver$
$
$
$
$
$
$
$
Adding'a'remote'to'the'remote'receiver'
There$are$two$steps$to$adding$a$remote$transmitter$to$the$IDS805.$
The$first$is$to$put$the$remote$receiver$into$learn$mode$and$the$
second$is$to$put$the$IDS805$into$add$user$mode.$
Remote$Receiver$
1. Put$dipswitch$3$on$the$remote$receiver$ON.$(Fig$1)$
IDS805$Alarm$
1. Hold$[*]$till$BEEP$
2. Enter$[MASTER$CODE]$[*]$$
3. Enter$[USER$No.]$[*]$$
4. Enter$[4$Digit$CODE]$[*]$
5. Press$and$hold$a$button$on$the$remote$transmitter$until$the$
keypad$beeps$
6. When$complete$press$[#]$
7. Put$dip$switch$down$
$
$
$
$
Trouble'Conditions'
If$the$POWER$LED$is$flashing$(or$if$so$programmed,$the$keypad$is$
beeping)$hold$down$the$[7]$key$for$one$second$to$see$which$zone$
indicator$is$on.$
Indicator$
Trouble$Condition$
2$
Failure$to$communicate$to$monitoring$company$
3$
Mains$power$failure$
4$
Low$battery$
5$
The$Telephone$line$has$been$cut$or$is$not$present$
6$
The$siren$wire$has$been$cut$or$the$fuse$has$blown$
7$
Keypad$has$experienced$a$tamper$
8$
Installers$code$must$be$entered$to$clear$an$alarm$
condition$
Note:$If$the$trouble$has$been$fixed$pressing$the$[#]$key$within$5$
seconds$of$entering$the$trouble$view$will$clear$the$trouble$
condition$indicator$
Issues'when'arming'
Before$you$call$for$your$installer$please$verify$the$following:$
Is'the'READY'Indicator'on?'
If$this$indicator$is$not$on,$one$or$more$zones$are$violated.$A$
flashing$zone$indicator$shows$a$violation.$Ensure$that$all$
monitored$doors$and$windows$are$closed.$Bypassing$a$violated$
zone$will$also$create$a$READY$condition.$
Does'the'siren'sound'before'you'exit?'
The$exit$delay$may$be$too$short$-$ask$your$installer$to$adjust$
the$exit$delay.$
OR$
You$have$not$left$via$a$Follower$and$Entry/Exit$zone$or$have$
strayed$into$an$Instant$zone.$Either$avoid$these$zones$or$ask$
your$installer$to$change$the$zone$type.$
Issues'when'disarming'
Does'the'siren'sound'immediately'upon'entry?'
You$have$not$entered$via$the$Entry/Exit$zone$or$have$strayed$
into$an$Instant$zone.$
Does'the'siren'sound'before'you'get'to'the'keypad?'
You$have$strayed$into$a$non-follower$zone$
OR$
You$have$taken$too$long$to$get$to$the$keypad.$
The'panel'will'not'disarm.'
You$may$have$entered$an$incorrect$code.$
Press$the$[#]$key$first,$then$re-enter$your$user$code.$
IMPORTANT'INFORMATION'
- Alarm$Panels$are$not$infallible$
- The$quality$of$installation$of$your$panel$will$determine$its$
effectiveness.$Ensure$that$your$panel$has$been$installed$by$an$
IDS-accredited$installer$
- Do$not$access$or$program$locations$reserved$for$professional$
installers$as$this$might$compromise$your$installation$
- Test$the$system$regularly$$
ZONE'INFORMATION'
$
Zone$
Location/Function$
1$
$
2$
$
3$
$
4$
$
5$
$
6$
$
7$
$
8$
$
$
INFORMATION'
$
Date$Installed$
$
$
$
Installer$Name$
$
Company$Name$
$
Contact$Details$
$
$
$
Security$Company$
$
Control$Room$Number$
$
$
$
Dip$Switches$

Other manuals for IDS805

1

Other IDS Keypad manuals

IDS 816 User guide

IDS

IDS 816 User guide

IDS LCD Digital Keypad User manual

IDS

IDS LCD Digital Keypad User manual

IDS 805 User guide

IDS

IDS 805 User guide

IDS X Series User manual

IDS

IDS X Series User manual

IDS IDS805 User manual

IDS

IDS IDS805 User manual

IDS X Series User guide

IDS

IDS X Series User guide

IDS X64 User manual

IDS

IDS X64 User manual

IDS X64 User guide

IDS

IDS X64 User guide

Popular Keypad manuals by other brands

intertel AXXESS user guide

intertel

intertel AXXESS user guide

Doorentryonline 596KP user manual

Doorentryonline

Doorentryonline 596KP user manual

XPR Access MTPADP-EH-SA user manual

XPR Access

XPR Access MTPADP-EH-SA user manual

Contro l4 KPZ-3B1 Specifications

Contro l4

Contro l4 KPZ-3B1 Specifications

Contro l4 C4-KC240 installation guide

Contro l4

Contro l4 C4-KC240 installation guide

Paradox Grafica User quick reference guide

Paradox

Paradox Grafica User quick reference guide

Paradox Digiplex User quick reference guide

Paradox

Paradox Digiplex User quick reference guide

Gearhead KP3200CW user manual

Gearhead

Gearhead KP3200CW user manual

Paradox Imperial Digiplex Evo R915 manual

Paradox

Paradox Imperial Digiplex Evo R915 manual

essentiel b NK-10-SF user guide

essentiel b

essentiel b NK-10-SF user guide

Abus HomeTec Pro CFT3000 manual

Abus

Abus HomeTec Pro CFT3000 manual

ECKey EK2 quick guide

ECKey

ECKey EK2 quick guide

ADEMCO 4137AD Mounting instructions

ADEMCO

ADEMCO 4137AD Mounting instructions

Kyungwoo SMK TAG B PCB user manual

Kyungwoo

Kyungwoo SMK TAG B PCB user manual

DKS 1503 owner's manual

DKS

DKS 1503 owner's manual

Satel CA-6 KLED quick start guide

Satel

Satel CA-6 KLED quick start guide

Sony PS3  CECHZK1TW instruction manual

Sony

Sony PS3 CECHZK1TW instruction manual

Waterproof W1-B user manual

Waterproof

Waterproof W1-B user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.