TRI-GARD 555LS/557LS SIGNATURE SERIES™
audio glassbreak detectors employ state-of-the-art Advanced
Signature Analysis™ algorithms to sample four bands of audio
instead of one or two like most other detectors. Digital Signal
Processing(DSP)isusedtocontinuouslysampleandanalyze
the sound. Within milliseconds after an audio “event” begins,
themicroprocessorstarts crunchingdata.Approximately1200
comparisonsanddecisionsaremadebeforeaneventisreject-
ed or confirmed about 0.3 seconds later. Eight glassbreak sig-
nature models and four false alarm models, stored in memory,
are referenced during the confirmation process. The result of
thishigh-techperformanceis more accurate glassbreak detec-
tionandimprovedfalse alarm rejection in tough environments.
TRI-GARD 555LS/557LS FEATURES
• Specified for plate,wired, tempered & laminated glass
• Microprocessor-based for better discrimination
• Advanced SignatureAnalysis™
• Signature Supervision
• Omnidirectional sensitivity
• Automatic sensitivity adjustments
TRI-GARD 555LS/557LS APPLICATIONS
• Glassbreak protection in residential,commercial
and industrial areas
• Protects plate,wired, tempered & laminated glass
• Omni direction detection to protect multiple windows
•Areas with closed drapes or blinds will reduce range.
Test with 517 tester for specific range
•Wall orceiling mount installations
SPECIFICATIONS
SENSING:Audio/air,open space (enclosed area)
RANGE: 25’ for plate, wired, tempered & 20’ for laminated
glass. These ranges are for 1’ X 1’ minimum glass size. For
glass size down to 6” X 10” the range would be reduced by
1/2.
GLASS SIZE: Above stated range is for 1’ X 1’
THICKNESS:Plate- 3¼32" to1¼2"
Tempered–1¼8" to1¼2"
Wired–1¼4"to 1¼2"
Laminated–1¼4" to1¼2"
SENSING FIELD: Omni-directional
SENSOR: Electret condenser (F.E.T.pre-amp)
OPERATING VOLTAGE: 10–16VDC filtered and regulated
POWER CONSUMPTION: 30 ma@13.6VDCnormal,40ma@
16VDC.
OPERATING TEMPERATURE:14° to120° F (-10° to 49° C)
STORAGE TEMPERATURE:-13° to185° F (-25° to 85° C)
RELAY ACTIVATION TIME: 3 seconds
ALARM LED: Latch orauto reset
ALARM RELAY: SPDT (Form-C)- contacts .1Amp @30VAC/24
VDC Relay is energized upon power up (C & NC are closed)
TAMPER CIRCUIT: Normally closed switch-contacts 50
milliamps @ 30VAC/24VDC.
VOLTAGE MONITOR: Low or novoltage causesalarm relay to
open. Lowvoltage <10VDC causes red LED to flash slowly
INSTALLATION: Hardwire 6wires including 2 for tamper
Testing: Follow instructions & test once a year
MOUNTING: Surface– screw andanchors included
COLOR:White or Cabin Brown
SIZE: 3" x 3" x 3¼4"
TRI-GARD555LS/557LSSignature Series™
Audio Glassbreak Detectors
NOTE 1: The use of mini-blinds, shades, drapes* and sun film* can
reduce the range of the detector by 50%. Since room acoustics and win-
dow coverings can vary considerably, all detector installations should be
checked with the 517 tester.
* Not for sound deadening drapes
* Tested w/ 3M sun film #SH2CLAR (3M is a trademark of 3M Company)
555LS 557LS

MOUNTING LOCATIONS
TheTri-Gardcanbemountedonanytypeofceilingorwall.
The detector should be no closer than 4 feet from the glass to
be protected.Since the sound waves of breaking glass travel
directionally out at a 90° degree angle from the broken win-
dow, the best mounting location is on the opposite wall,
assuming the wall is within detection range.
Formaximumperformanceinstallthedetectorindirectline of
sighttoallglassthatyou are protectingandlocatethedetector
atleast1footfromany corner orceiling.
Forbestfalsealarmimmunitythe detector shouldbemounted
atleast4’fromtheglass to beprotectedandfromnoisesources
suchaskitchensinks,stereos,televisions,etc.
WALL MOUNTING
Mount the detector on an opposite or adjacent wall from the
glass to be protected.
The unit should be mounted at least 6 feet from the floor. This
will ensure that no furniture or other objects will block the
direct line of sight, thereby providing maximum glassbreak
protection.
NOTE:The unit should not be mounted on the same wall as
the glass to be protected.
CEILING MOUNTING
Mount the 555LS/557LS in any location on the ceiling which
is in direct line of sight of the glass to be protected.
To ensure maximum glassbreak detection do not mount the
detector within 1 foot of any side wall.
Mount the 555LS/557LS on any solid material.
555LS/557LS OPERATIONS AND WIRING
On power-up the microprocessor will momentarily turn on
each LED.
LEDs Operation:
• Green LED ON–solid indicates unit is properly powered.
• Green LED OFF–indicates that the relay has dropped out,due
to the detector being tripped or no/low power (<10VDC).
• Green LED BLINKS–slowly to indicate that the unit is in test mode
(see test mode).
•Green LED FLASHES–when there are background noises
present within the detection range.
•Amber LED ON– solid indicates that the “Signature Supervision”
has not been able to test all circuits within the last120 hours.
• Red LED ON–solid indicates that the detector has been tripped
and is in a latched alarm memory condition.
• Red LED FLASHES–to indicate that there is an alarm for low
power condition, input voltage is (<10VDC).

TESTING THE 555LS/557LS
DIP SWITCH 1– (Test Mode Enable)
Testmodeallowstheinstallerto properlytestthe555LS/557LS
withtheIEI 515OR 517GLASS BREAK SIMULATOR.
NOTE:The515testerwilltestforbasicoperationofdetector,
suchasmicrophoneresponseandproper alarmrelayoperation
,butitwillnottest forproperrange. The517testerisrequiredfor
properrangeverification.
Manual Test Mode with 515 or 517 Tester:
Toenable testmodemomentarilymoveDIP switch1from the
offpositiontotheonpositionandthen returnitback totheoff
position.The green LED willblink slowly. Youhavetwo
minutestotestthedetector.Eachtimeyoutripthedetector,indi-
catedbythegreenLEDturning offandtheredLEDturningon
forthreeseconds,youwillre-startthetwominutetest time
(NOTE: theredLEDwill notlatchduring testmodeevenifyou
haveDIPswitch2:alarmmemory on).Ifyoudonot tripthe
detectorwithinthetwominutetest period,thedetector willreturn
tonormalglassbreakmode,indicatedbythesolidgreenLED.
Toimmediately returntonormalglassbreakmodeafterthe
detectoristestedcorrectly,simplyinterruptpower foronesec-
ond.
Remote Test Mode with 517 Tester:
Totestremotely with517 testermove DIPswitch1 tothe on
position. Step backabout 10feet fromthedetector andpress
thetester“To Test” button. The detectorshould nowentertest
modeindicatedbythe slowlyblinking greenLED. Positionthe
517nearthefarthest pointof theprotected glassandpoint the
testerdirectlytowardthe detector. Closeany curtains,drapes
orblindsandhold testerbehind windowcovering toensure
properlocationofdetector. Selectthespecificglasstypeand
sizeandpushthe appropriatekey onthe tester.Observethat
theunittripsconsistently. Whenfinishedyoucanexit testmode
bypressingthetester “Test Off”button,interrupt powermomen-
tarilyorsimply letthe 2minute testwindowexpire.
NOTE:With DIP switch 1 in the on position, test mode can
be entered remotely at any time with the 517 tester
NOTE:Test mode does not prevent the 555LS/557LS from
detecting breaking glass.
INSTALLATION OPTIONS
DIP SWITCH 2– (Alarm LED Latch Mode)
• OFF–Red LED lights for 3 seconds on alarm and then
turns off.
• ON– Red LED will latch in memory upon an alarm.
Interrupt power or turn dip switch 2 off & on to reset.
DIP SWITCH 3– (Signature Supervision)
• OFF– Normal operation- without “Signature Supervision”.
• ON– Enables “Signature Supervision” processing.
SIGNATURE SUPERVISION™
Usingamicroprocessorenables thedetector toprocess more
datatomakebetterdecisions indetermining aglassbreak
eventandalsoprovide moreinformation backto theuser
regardingtheoperatingstatusof thedevice. Aglass break
eventoccursovera broadfrequency range.There arefrequen-
ciespresentfrom10to40,000cycles duringa glassbreak
event.Signature Supervisionmonitorsthe inputfrom themicro-
phoneandtheassociated circuitryto insurethat theunitcontin-
uesto“hear”across thefrequency spectrum.If,after120hours
(5days),thesensor hasnot heardtheindividualfrequencyele-
mentsassociatedwiththesignature frequencieswithin glass
breaktheamberLED willcome onand staylatched toindicate
apotentialtroublesituation (NOTE:thisdoesnottrip thealarm
relay).Whenthedetector hasheard thoseparticularfrequen-
ciesassociatedwithglass break,theamberLEDwillreset.
Clapping,for example,willoftenproduce therange offrequen-
555LS
CIRCUIT
BOARD
557LS
CIRCUIT
BOARD
NOTE: Tamper spring is in hardware package with screws

THIS DEVICE COMPLIESWITH PART15 OF THE FCC RULES.OPERATION IS
SUBJECTTOTHE FOLLOWINGTWO CONDITIONS: (1)THIS DEVICE MAY NOT
CAUSE HARMFULINTERFERENCE,AND (2) THIS DEVICE MUSTACCEPTANY
INTERFERENCE RECEIVED,INCLUDING INTERFERENCETHAT MAY CAUSE
UNDESIRED OPERATION.
WARNING: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
NOTE:This equipment has been tested and found to comply with the limits for a Class
B digital device,pursuant to Part15 of the FCC Rules.These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates,uses and can radiate radio frequency energy and,if not
installed and used in
accordance with the instructions,may cause harmful interference to radio communica-
tions.However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Re-orient or relocate the receiving antenna
• Increase the separation between the equipment and the receiver
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV
technician for help
IEI Limited Warranty:
Because the manufacturer does not install or connect this security device the manu-
facturer cannot guarantee its performance.Therefore,there are no warranties,
expressed or implied (except as stated below),attached to the sale or use of this prod-
uct.
The manufacturer warrants against defects in material and workmanship in this device
for 3 years from the date of manufacture.During the warranty period the
manufacturer, at its sole option,will repair or replace free of charge any defective unit
returned freight prepaid.This warranty shall remain in force and effect for 3 years pro-
vided the unit was properly installed and operated,has not been subject to misuse and
has not been repaired or altered other than by the original manufacturer.
The foregoing states the buyer's sole and exclusive remedy for any breach of warranty
or for any claim,whether sounding in contract,tort,strict liability,or negligence,based
upon any defect in this security device.
The manufacturer shall in no event be responsible for any incidental or consequential
damages incurred by the buyer.
This warranty supercedes all previous warranties.
ciesthatarepresent inglass breakand canbeused toreset
theunit.Noticethat whileclapping willresettheSignature
Supervision,it willnotcause analarm becauseit doesnotmeet
othercriteriathatthe microprocessoris usingto determinea
trueglassbreakevent.Thisfeature isdipswitchselectable.
NOTE: If the amber LED is lit and is unable be to reset by
clapping,the customer should contact the installing dealer.
PRE-TESTING THE TRI-GARD 555LS/557LS
FOR DESIRED LOCATION
Pre-testing of the detector prior to final installation can be
performed to ensure that the detector is installed in the
proper location with respect to all glass being protected.
The IEI 517 Glass Break Simulator is required to perform
this test.
WARNING:
The 555LS/557LS detector has been designed to detect
glass break within a specified range from the glass–(25' for
plate, tempered,and wired glass glass and 20' for laminated
glass).You should not extend past these rated ranges for any
reason. Acoustics of different areas can artificially extend the
range of the tester.
1) Connect a 9Volt DC alkaline battery or 12 VDC power
source.
2) Proceed to section: Testing the 555LS/557LS
NOTE: the red LED will flash slowly indicating low voltage
(input voltage <10VDC) and also the relay will not be ener-
gized (common and normally closed will be open).
CAUTIONS
•Toimprovefalsealarmrejectiondonotusefor24hourapplica-
tionsinoccupiedareas,areaswherewhitenoise,suchasair
compressorsormachinerymaybepresentorwithin4feetof the
glassbeingprotected.
• Performance of any audio detection device depends upon
an audible signal and may be compromised when detecting
glassbreak if little or no sound is generated. For example,
avoid installations with sound insulating window coverings.
427 TURNPIKE STREET, CANTON, MA 02021 U.S.A.
800-343-9502 OR IN MA 800-733-9502
555/557 REV. 1.01 617-5550 MADE IN U.S.A.
This manual suits for next models
1
Table of contents
Popular Security System manuals by other brands

DSC
DSC GSM0110 installation instructions

Pima
Pima SRO143 installation instructions

Dantel
Dantel A23-41073-00 Installation & operation manual

Visonic
Visonic PowerMax Partitions II Quick installation guide

Velleman
Velleman HAM200 user manual

Alderon Industries
Alderon Industries Versa'larm 4X Operation, maintenance and installation manual