ionmax Ion632 User manual

User’s Manual
Inside you will find many helpful hints on how to use and maintain your dehumidifier properly. Just a
little preventative care on your part can save you a great deal of time and money over the life of your
dehumidifier. You’ll find many answers to common problems in the chart of troubleshooting tips.
Review the chart of Troubleshooting Tips before calling your engineers

INDEX
IMPORTANT SAFETY INSTRUCTIONS ..................................................................................
FEATURES & SPECIFICATIONS.............................................................................................
PRODUCT DESCRIPTION ......................................................................................................
THE CONTROL PANEL ...........................................................................................................
UNIT SETUP.............................................................................................................................
TO OPERATE SAFELY ...........................................................................................................
OPERATING INSTRUCTIONS .............................................................................................
TO EMPTY THE BUCKET ......................................................................................................
TO DRAIN WATER (Continuous Drainage) ............................................................................
MAINTENANCE ......................................................................................................................
TROUBLESHOOTING ............................................................................................................
WARRANTY DETAILS ............................................................................................................
1
2
3
4
5
5
6-9
10
10
11
12
13

IMPORTANT SAFETY INSTRUCTIONS
1
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.
WARNING - This appliance is intended for use in a domestic environment only. Any other
use is not recommended by the manufacturer and may cause fire, electrical shocks or
other injury to person or property.
When using electrical appliances, basic safety precautions should always be followed:
1. Do not operate the unit with a damaged cord or plug, after it malfunctions or has been
dropped or damaged in any way. Return to an authorized service facility for examination
and repair.
2. This unit should always be kept in an upright position to avoid any damage. Locate the
unit on a flat stable surface.
3. Check the household voltage to ensure it matches the units rated specification before
operating.
4. Operate this unit in an ambient temperature between 1°C and 40°C.
5. Ensure that the air inlets and outlets are not blocked or covered.
6. Do not place the unit too close to curtains or other objects - min 40cm.
7. When using the "LAUNDRY MODE" to speed up the drying of wet clothes in the room,
please keep the clothing at a safe distance from the unit to prevent water from dropping
onto the unit.
8. Never place anything on top of the unit and do not cover with any kind of material while
in use.
9. This product is intended for domestic and light office use ONLY and not for commercial,
industrial or outdoor use.
10. To protect against electrical shocks, do not immerse unit, plug or cord in water, or spray
with liquids.
11. Never unplug the power cord without press the "ON/OFF" key to off first, as this could
damage the unit.
12. Always unplug the unit when not in use or moving location. To disconnect from the
power supply, grip the plug and pull from the power socket. Never pull by the cord.
13. Always empty the water tank before storing the unit away.
14. Close supervision is necessary when any appliance is used by or near children and pets.
15. Do not run power cord under carpeting, or cover with rugs or runners. Arrange the
cord away from areas where it may be tripped over.
16. Never operate or store the unit in direct sunlight.
17. To repair the unit, take it to a qualified service engineer. Repairs carried out by
unqualified people may cause damage to the unit or injury to persons or property and
void the warranty.
18. Where possible, avoid the use of an extension cable as they may overheat and cause
a risk of fire. Only use an extension cord after ensuring it is in perfect condition.
19. Do not use the unit without the air filter.
SAVE AND READ THESE IMPORTANT SAFETY INSTRUCTIONS
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
1

FEATURES
2
SPECIFICATIONS
• Compressorless dehumidifier - uses desiccant rotor technology
• Automatic swing louvre
• Moisture removal - 10 litres/day (20°C RH60%)
• Water tank capacity - 3.5 litres
• Electronic louvre
• Built-in heater
• Laundry mode - helps to dry out damp clothes
• Up to 8 hour timer - for added convenience
• Temperature range for use ~ 1°C - 40°C
• Light & portable with carry handle
• Removable water bucket with handle
• Auto restart after power cut
Once the power is restored after a power failure, the appliance will continue
to operate at the selected settings prior to the power failure.
• Safety function
Adaptive control, Fall-down, water-full and abnormal temperature detection
Model: Ionmax Ion632
Voltage: 220-240V ~ 50Hz
Power consumption: 400-720W
Net weight: 8.4kg
Dimensions (W x D x H): 416mm x 186mm x 520mm

PRODUCT DESCRIPTION
3
Bucket

4
THE CONTROL PANEL
Water Full indicator
Indicator lights up when the bucket is full of water or
incorrectly installed.
Check indicator
Indicator lights up when the unit malfunctions.
Timer indicators
Function indicators
Timer key
Louvre Swing Control key
Laundry Mode key
Auto Dry Mode key
Power Key

6
OPERATING INSTRUCTIONS
ON and OFF
Connect the power plug to the appropriate electrical socket outlet.
Press the ON/OFF button to turn the appliance ON.
Press the ON/OFF button again to turn the appliance OFF.
Note: In the event of a power failure
Once the power is restored after a power failure, the appliance will continue to
operate at the selected settings prior to the power failure.
This includes the drying mode, swing function and time remaining in timer mode.
Note: After turning the appliance OFF
After turning the appliance OFF using the ON/OFF button, the fan will continue
to run for a two minute period. This is a normal procedure and helps to cool &
protect the internal components.
During this two minutes DO NOT remove the power plug from the electrical
socket outlet; wait for the fan to stop running.

OPERATING INSTRUCTIONS
7
DRY MODE
Auto
Low
Hi
DESCRIPTION
Turbo
Saving
Press the "DRY” Key for automatic dehumidification.
MODE DESCRIPTION
The unit automatically keeps room at a comfortable
Relative Humidity (RH) level of 55%RH.
The fan speed & heater power are adjusted automatically.
Note: Use this mode for maximum energy saving and for quiet operation.
Note: Use this mode on a daily normal household use to keep the humidity to
a healthy level of 55%RH (Bacteria and mould will not breed at this level).
Note: Use this to control a very damp room in the first couple of days and then
switch to economy to save energy.
Dries the air to approximately 55%RH and runs on economy
fan mode to sample the air for its humidity level. It will
dehumidify again when the relative humidity rises.
Dries the air to approximately 45%RH and stops dehumidifying
but runs on fan-only mode to sample the air for its humidity level.
It will dehumidify again when the relative humidity rises.
LAUNDRY MODE
Pressthe "LAUNDRY" key for drying clothes.
MODE
Use this mode to increase the toggling to low energy saver
mode during operation.
The unit automatically provides heat air to dry clothes faster
with higher power. During the operation the power will be
toggled to low energy mode as air humidity gets low.
Note: It typically takes 2 – 8 hours to dry your laundry. You may want to put your
dehumidifier on the timer when using the Laundry mode to avoid wasting energy.
Avoid using the Laundry modes for normal daily use. You may use for extreme
drying of very damp rooms over 2 – 3 days and then switch to the recommended
Low mode.

8
OPERATING INSTRUCTIONS
AUTO SWING LOUVRE
Pressthe"SWING"Keytoselectairlouvreangle.
MODEDESCRIPTION
Up FrontWide
Hold
(LEDOFF)
TOP
FRONT
WIDE
Up
Front
Wide
Hold
Theautomaticlouvreswings in an upward
range of approx100
°
TIMERMODE
CHECK ALERT
Pressthe"TIMER" Key to selectyourdesiredrunningtime(2,4 or 8 hours).
Theunitwillautomaticallyswitch off at the end of theselectedtimeperiod.
Theautomaticlouvreswing inawide
range of approx150
°
Theautomaticlouvrestopsswingingwhenyoupress
"SWING"keyandturnsthe LED off.
Theautomaticlouvreswings in a front
range of approx 50
°
Lights up when:
1. Filter needs cleaning
2. Appliance needs to cool down. Unplug and leave for 30 minutes before re-try.
3. In low humidity or temperature conditions
4. In high temperature condition over 35 °C
Note: When the check light comes on, remove the main plug from the socket. Move
it to another room after it cools down or when conditions allowed, put the main plug
back to the socket and turn on the unit. Make sure the dehumidifier is placed in a
safe distance away from any obstacles. (See page 5 Unit Setup)

9
Smell coming from the dehumidifier
When you first use the dehumidifier and periodically afterwards you might notice
a smell coming from the dehumidifier. This is caused by the Zeolite desiccant material
and is not a sign that the dehumidifier is faulty, nor is it harmful to humans or pets.
The smell occurs because the Zeolite absorbs odours from items like cigarettes,
cosmetics, hair sprays, building materials and new furniture and then when the
desiccant is heated the smell is discharged into the room. This smell has been
described as being like a burning smell or a sour smell. It is normal, will not last long
and is not a sign of a fault.
Amount of water collected
When you first use your dehumidifier it will work harder to reduce the room humidity
to it's target of 45-50%RH, this is the time when it will produce the most water and need
emptying most frequently. As the room becomes dryer the dehumidifier collects less
water and runs at a lower fan speed. This is normal. When the target relative humidity
has been reached the air coming out of the dehumidifier will not be heated and it will
only be running in low fan mode. This is because there is no need for dehumidification
at this point and the dehumidifier is sampling the air to check the current relative humidity
to see if dehumidification is required.
If you find that you still have condensation on your windows or you need to dry the air
further then using the High fan speed, or the Turbo Laundry mode, will force the
dehumidifier to dry the air further to 40%RH. This might well be necessary if you have
single glazed windows or if the outside air temperature drops to freezing.
PLEASE NOTE

TO EMPTY THE BUCKET
0
10
Lift by the handle
Pull bucket out
Remove the coverPourthe water contentsRefit the cover Restore the bucket
1. When the bucket is full, the FULL LED lights up and the unit stops.
2. Do not move the unit or remove the bucket, if the machine is still operating, as
water may leak, damage the unit or cause an electric shock.
3. To remove the bucket, pull it out by
gripping the bottom of the bucket,
and lift carefully.
4. Remove the cover of bucket first,
then pour the water away, clean the
bucket and restore the cover and the
bucket to the correct position.
NOTE:
Clean the bucket with clean water if needed. Do not use detergent, solvent,
abrasive or hot water to avoid damage to the appliance.
Do not remove or damage the float in the bucket, the unit will not work correctly.
The bucket cover must be well fitted in position.
The "FULL" LED lights if the bucket is not well in place.
A B
C D E F
PERMANENT DRAIN OPTION
A hose with an inner diameter of 12mm can
be connected for continuous drainage.
1. Remove the bucket.
2. There is a through hole at the lower left
corner on the back of the appliance.
3. Pass the hose through the hole.
4. Remove the plug from the drain hole at
the back of the bucket. Keep it safely for
future use.
5. Push and connect the hose firmly to the
drain hole of the bucket.
6. Restore the bucket in the correct position.
21
34
65

!
TO OPERATE SAFELY
5
CAUTION: Do not place the dehumidifier in a broom cupboard,
boiler room, small unventilated rooms etc. Avoid placing the
dehumidifier in small confined areas or in close proximity to a
radiator or heat source such as tumble driers, cookers etc. to
avoid the dehumidifier from overheating.
Do not use this dehumidifier in dusty or an industrial
environment where particles can get into the dehumidifier.
This will cause a malfunction and void your warranty.
UNIT SETUP
Place the unit in an upright position on a
stable, level surface. (Please ensure unit
is not sitting on its own cable)
Please ensure the unit is a safe distance away
from a wall or furniture (see the right graphic).
Please keep clothes at a safe distance of
60cm from air outlet of the unit to prevent
water dripping into the unit.
Where to position your dehumidifier?
For best results position the dehumidifier
somewhere central like a landing or a hallway.
As long as the internal doors are open
the excess moisture from all of the rooms
in the house will migrate naturally towards
the dehumidifier and be processed.
Top above 60cm
Air outlet
Air inlet
(Back)
above 20cm
above 20cm
above 20cm
above 50cm
Do not insert small
objects into the unit or
this will damage it and
cause a hazard.
Do not attempt to remove
bucket while unit is in
operation to avoid water
leakage.
Keep suitable space
as above
Ensure bucket is
fitted correctly.

MAINTENANCE
11
1. Turn the appliance OFF, wait for the fan to stop and ensure the plug is removed from
the socket outlet.
2. Clean the casing using a soft damp cloth with warm water and mild detergent.
Do not use solvents or abrasive materials.
3. Use a soft dry cloth to wipe the casing dry.
4. To avoid damage to internal parts, do not let water to drip into the air inlet or outlet
and do not wash the machine with water.
1. Turn the appliance OFF and ensure the plug is removed from the socket outlet.
2. Remove the filter located at the back of the appliance.
3. Clean the filter using clean water and dry it before use, or alternatively clean using
a vacuum cleaner.
4. Restore the filter into the appliance.
5. Never run the unit without the filter.
If the filter is covered by plenty of dust, the airflow and performance of the unit will be
affected and mulfunction may occur. It is recommended to check and clean the filter
every two weeks.
Cleaning the unit
Cleaning the filter
Before storing
1. Turn off the unit, wait for it to stop and unplug from the power socket.
2. Clean and dry the bucket. Leave the unit to drain for approximately one day.
3. Clean the filter and the unit. Cover the unit to prevent it from
gathering dust. Store upright in a cool dry place.
4. Do not expose to direct sunlight.

TROUBLESHOOTING
12
NOTE:
1. If the "CHECK" LED illuminates, turn off the unit, unplug from the power socket,
check and clean the filter. If it is dirty, remove any obstacle that covers the air inlet or
outlet, and wait for at least ten minutes before plugging in and switching back on.
2. Please contact your retailer if the problem continues.
Do not try to repair it yourself, as this could cause an electrical shock and void your
warranty.
Problem
Dehumidifier
doesn’t start
(no lamp)
FULL lamp
lights
Water on floor
Water Less
CHECK lamp
lights
The unit is unpluggedMake sure the plug is pushed completely
into the outlet.
The bucket is full or not in place Empty the bucket, check the float in
position, and replace the bucket.
The unit falls down or is not level
on the floor / surface
Place the unit on a stable, level surface.
The air inlet or outlet is covered /
blocked
Filter clogged with dust
Make sure there is nothing blocking the air
inlet and air outlet of the unit. Clean the
filter. Unplug and wait at least 10 minutes to
resume operation.
The ambient temperature is too
high, such as over 40ºC
Do not use it in a small and closed place
where heat accumulates.
Move to a cooler place, wait at least 10
minutes to resume operation.
The unit is not levelCheck the unit is placed on a level
surface and not accidentally sitting on a
cable etc.
The drainage is clogged or loose Check the drainage hose and its
connection.
The fuse is blown or circuit
breaker is tripped
Check the house fuse / circuit breaker box
and replace fuse or reset the breaker.
The room humidity has reached
the setting
It uis normal, you may choose Hi orTurbo
mode if you need a drier humiditylevel.
Possible CausesWhat to Do
The following conditions are normal:
1. The fan is still running about 2 minutes after turning off the the unit.
2. The unit works within room temperature about 1~40ºC. It may stop operation
out of this range or when the air inlet or outlet is covered. (The "CHECK" LED light
will illuminate)
3. The unit includes heater function that could increase the room temperature.
If your Dehumidifier stops working or "CHECK" LED illuminates, please check the following
items first.

WARRANTY DETAILS
13
WARRANTY D E TA I L S
Congratulations on your purchase! It is our aim to provide you with quality products that you can
trust. Our products come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or a refund for a major failure and for compensation for any
other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure.
The Guarantee
The product is guaranteed to be free from defects in workmanship and parts for a period of 12
months from date of purchase for domestic use and 3 months for commercial use. Defects
that occur within this warranty period, under normal use and care, will be repaired, replaced or
refunded at our discretion, solely at our option with no charge for parts and labour. The benefits
conferred by this warranty are in addition to all rights and remedies in respect of the product that
the consumer has under the Trade Practises Act and similar state laws.
Proof of Purchase
This warranty is valid for the original purchase and is not transferable. Please keep your purchase
docket or receipt as proof of purchase and as proof of date on which the purchase was made. The
purchase docket (or a copy) or receipt must be presented with the warranty when making a claim
under this warranty.
Service during the Warranty Period
Please ensure that the RA# (Return Authorization Number) is clearly stated on the outside of the
packaging. Don’t have one? Call us on 1300 800 200 and we’ll get you one. Please ensure the
product is properly packaged so as to ensure that no damage occurs to the product during transit.
Extent of Warranty
This warranty is limited to defects in workmanship or parts. All defective products or parts will be
repaired or replaced. This warranty does not cover manuals and packaging.
Normal Wear and Tear
This warranty does not cover normal wear and tear to the product or parts.
Exclusions
This warranty does not cover:
• Any defect caused by an accident, misuse, abuse, improper operation, lack of reasonable
care, unauthorised modification, loss of parts, tampering or attempted repair by a person not
authorised by the distributor.
• Any product that has been damaged by a lightning strike either directly or indirectly or a mains
power surge or liquid ingress.
• The product if it is located outside of Australia.
• Any damage caused by improper power input or improper cable connection.
Andatech Corporation Pty. Ltd.
Factory 7, 2-4 Apollo Court, Blackburn Victoria 3130
Phone: 1300 800 200 Fax: 1300 883 802 Email: info@andatech.com.au

Other manuals for Ion632
2
Table of contents
Other ionmax Dehumidifier manuals

ionmax
ionmax ION622 User manual

ionmax
ionmax DRYFAN DF8 User manual

ionmax
ionmax ION610 User manual

ionmax
ionmax VIENNE User manual

ionmax
ionmax ion612 User manual

ionmax
ionmax Leone ION625 User manual

ionmax
ionmax ION681 User manual

ionmax
ionmax ION680 User manual

ionmax
ionmax ion612 User manual

ionmax
ionmax Rhine ION650 User manual