  9. IR-Tec DUOGUARD DP-150 User manual

IR-Tec DUOGUARD DP-150 User manual

DUOGUARD
PIR + Microwave Motion Detector
DP-150/150L Installation Instructions
INTERNAL VIEW
ALARM TAMPER SW4
C17
C28
BY1
C31
C4
C33
C32
LED2
LED3 LED1
1/3 MAX.
2/3
MW.RANGE
C10 C12 C8
ALM
MW
PIR
SWB
SWA
CT35
Terminals
Microwave
sensor
PIR LED
(Yellow)
Microwave range
adjustment
Tamper switch
Relay
Alarm LED
(Red)
Infrared sensor
(Don't touch!)
Microwave LEC
(Green)
Jumper switch
Locking bolt
Cable access
INSTALLATION HINTS
The DUOGUARD may be either wall or corner mounted
by applying different knockouts. The MB-95 or MB-99
mounting bracket can be applied for ceiling or wall
mount. Corner mount is generally recommended for
optimum detection. Do not install where the detector
is in or facing direct/reflected
sunlight, windows onto main
roads (car head lights) or strong
draughts / heaters.
Ensure that there are not any
obstructions (plants, screens,
furniture etc.) in the field of view
which may cause incorrect cover/
operation of the detector.
Avoid locating the detector in
areas which contain equipment
tha tmay change the environment
temperature rapidly.
Locate the detector at least 1
meter away from any illumination
to avoid possible interference to
microwave ensor.
)
Avoid running alarm wiring close to mains cables !!!
DETECTION PATTERN
Model: DP-150
110°, 15 x 15m at 25°C Top View
Side View
Model: DP-150L 90°
2.0m 8m 30m
INSTALLATION & WIRING
Installation
1. Open the front cover by loosening the locking bolt
at the bottom of the case.
2. Remove the printed circuit board from the base of
the unit, by bending the P.C.B clips gently
upwards (handle printed circuit board with care).
3. Punch out the required knockouts and mount the
unit base to the wall, corner or bracket.
4. Lead the cable through the access hole and then
refit the printed circuit board.
5. Connect the wires to the respective terminals
according to the wiring instructions.
6. Replace the front cover after completing the
wiring and carry out a through walk test.
Min. 1m Light
www.telefeeling.com
Wiring
+ALARM TAMPER
-
Tamper output (N.C loop)
Alarm output (N.C loop)
Power input (9 ~ 16 VDC)
)TAMPER terminals should be connected to the
24-hour N.C supervisory loop of control panel.
JUMPER SWITCH SETTING
MW
ALM
PIR
SWB
SWA
ON OFF
(Factory set)
ALM - Alarm LED Indication
ALM jumper ON OFF
Red LED ON OFF
MW - Microwave LED Indication
MW. jumper ON OFF
Green LED ON OFF
PIR - PIR LED Indication
PIR jumper ON OFF
Yellow LED ON OFF
SWA, SWB - Pulse count selection
Pulse Count 1 2 3
SWA jumper ON OFF OFF
SWB jumper OFF ON OFF
WALK TEST & ADJUSTMENT
It is necessary to carry out a thorough
walk test of the detector to ensure that
the correct coverage is being achieved
and no over spill of the microwave is
occurring. Also to ensure that both PIR & microwave
are working to the same detection area.
The PIR range sensitivity is not adjustable. Accurate
setting of the microwave is achieved by careful
adjustment of the microwave range controller on the
front of the PCB, next to the PIR detector, the range is
increased by turning the pre-set in clockwise direction.
When you are satisfied with your setting, all of the
LEDs may be disable from jumper switch (please retain
for future walk testing).
)Regular walk testing must be carried out, as part of
your routine maintenance visits or at least once a
year.)
MOTION SIGNAL DISCRETION
The MSD (Motion Signal Discretion) circuit recognizes
the difference between motion and non-motion signals.
Alarm output is only generated when motion is
detected by infrared & microwave sensor and analyzed
by the MSD circuit. MSD circuit ensures supreme
reliability even when environmental conditions are
severe.
SPECIFICATIONS
MW Frequency ..........10.525 GHz
Detection range.........15 x15 m at 25°C
Infrared sensor……….Low noise, dual element
Microwave sensor......DRO w/micro strip antenna
MW output power......6 mW E.I.R.P. peak
Power supply.............9 ~ 16 VDC (12 VDC nominal)
Current drain..............30mA at 12 VDC
Alarm period..............2 ±0.5 sec.
Alarm output..............N.C 30 VDC, 0.2A max.
Alarm output LED ......Red, can be disabled
MW sensor LED.........Green, can be disabled
PIR sensor LED..........Yellow, can be disabled
Pulse count................1, 2, 3 selectable
Tamper protection.....N.C cover open activates
RFI immunity..............Ave. 20V/m (10~1000 MHz)
Mounting height........2.0 ~ 2.4m (wall/corner mounted)
2.4 ~ 3.6m (with bracket)
Mounting bracket.......MB-95 or MB-99 (Optional)
Temperature..............-10°C ~ 55°C (14°F ~ 131°F)
Detection zones.........68 zones
Humidity.....................95% RH max.
Dimensions................125 x 68 x 42mm
Unit weight ................110 grams
In order to continue improving its product, IR-TEC reserves
the right to change specifications without prior notice.
1/3 MAX
MW RANGE
2/3
2003/03/03 058-15022-00 V2.0
www.telefeleing.com

This manual suits for next models

1

Other IR-Tec Security Sensor manuals

IR-Tec DUOGUARD DP-550P User manual

IR-Tec

IR-Tec DUOGUARD DP-550P User manual

IR-Tec Plato IR-580 User manual

IR-Tec

IR-Tec Plato IR-580 User manual

IR-Tec DP-150A User manual

IR-Tec

IR-Tec DP-150A User manual

IR-Tec ACTIVATA LC-200 User manual

IR-Tec

IR-Tec ACTIVATA LC-200 User manual

IR-Tec DP-363 User manual

IR-Tec

IR-Tec DP-363 User manual

IR-Tec DUOGUARD DP-550 User manual

IR-Tec

IR-Tec DUOGUARD DP-550 User manual

IR-Tec OS-361DT User manual

IR-Tec

IR-Tec OS-361DT User manual

IR-Tec DUOGUARD DP-250 User manual

IR-Tec

IR-Tec DUOGUARD DP-250 User manual

IR-Tec DUOGUARD DP-550 User manual

IR-Tec

IR-Tec DUOGUARD DP-550 User manual

IR-Tec LC-360HI User manual

IR-Tec

IR-Tec LC-360HI User manual

Popular Security Sensor manuals by other brands

seeed studio RG-9 quick start guide

seeed studio

seeed studio RG-9 quick start guide

Paradox NV35MR installation guide

Paradox

Paradox NV35MR installation guide

TAS TA430D instruction manual

TAS

TAS TA430D instruction manual

protech NoiseBuster PA4000 operating manual

protech

protech NoiseBuster PA4000 operating manual

Paradox NV780MX installation manual

Paradox

Paradox NV780MX installation manual

C.P. Electronics MWS1A-IP-PRM-VFC installation guide

C.P. Electronics

C.P. Electronics MWS1A-IP-PRM-VFC installation guide

Elmo AN900D150-2 manual

Elmo

Elmo AN900D150-2 manual

Paradox Magellan PMD75 instructions

Paradox

Paradox Magellan PMD75 instructions

C.P. Electronics EBDHS-KNX installation guide

C.P. Electronics

C.P. Electronics EBDHS-KNX installation guide

GM International D1030S instruction manual

GM International

GM International D1030S instruction manual

Paradox PMD85 user manual

Paradox

Paradox PMD85 user manual

C.P. Electronics EBDHS -KNX Instruction guide

C.P. Electronics

C.P. Electronics EBDHS -KNX Instruction guide

C.P. Electronics VITMR-MWS6-PRM Product guide

C.P. Electronics

C.P. Electronics VITMR-MWS6-PRM Product guide

GSM Activate ALARM PRO 20 quick start guide

GSM Activate

GSM Activate ALARM PRO 20 quick start guide

C.P. Electronics MWS3A-AD installation guide

C.P. Electronics

C.P. Electronics MWS3A-AD installation guide

Contro l4 Movement Detector 220 SM user guide

Contro l4

Contro l4 Movement Detector 220 SM user guide

HIK VISION Pyronix XDH10TT-WE quick start guide

HIK VISION

HIK VISION Pyronix XDH10TT-WE quick start guide

Maxouttech RF-CMDWS-OD-345-NN installation instructions

Maxouttech

Maxouttech RF-CMDWS-OD-345-NN installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.