iSysmart SGZB02I User manual

Sysmarti
ZigBeeTM- Wireless Panic Button
User Manual
Wireless Panic Button
Model: SGZB02I

2
Table of Contents
1.
Introduction ......................................................................................................................................................... 3
2.
Product Appearance.......................................................................................................................................... 4
3.
Specification........................................................................................................................................................ 5
4.
Installation Diagram .......................................................................................................................................... 6
5.
Setting up SGZB02I ........................................................................................................................................... 7
5.1.
Turn On SGZB02I........................................................................................................................................ 7
5.2.
Join the ZigBee Network ............................................................................................................................. 7
5.3.
Enroll in the ZigBee Security System.......................................................................................................... 7
5.4.
Sleeping Mode ............................................................................................................................................. 8
5.5.
HeartBeat Technique.................................................................................................................................... 8
5.6.
Battery.......................................................................................................................................................... 8
5.7.
Restore to Factory Setting............................................................................................................................ 8
6.
Home Automation Clusters for SGZB02I ..................................................................................................... 9
7.
Important Maintenance Instructions........................................................................................................... 11

3
1. Introduction
ISysmart SGZB02I, a wireless panic button, acts as an End Device in ZigBee network. It does not perform permit-
joinfunction as a coordinator or a router for other devices to join the network. When users ask for urgent assistance,
simply push the button, and SGZB02I (Zone device) will send the alarm message to the central security unit, CIE
(Control and Indicating Equipment) device, to send commands to a siren device to trigger an alarm. The Warning
Device will generate alarm sound or lighting alert for immediate help.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple
network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is defined for a
general-purpose, cost-effective, low-power-consumption, low-data-rate, and easy-to-install wireless solution for
industrial control, embedded sensing, medical data collection, smoke and intruder warning, building automation
and home automation, etc.

4
2. Product Appearance

5
3. Specification
Fully IEEE 802.15.4 compliant
Utilizes 2.4GHz ISM band; up to 16 channels
Power supply: 2 x AAA batteries.
Operating consumption: ≤40mA
Standby consumption: ≤1uA
Up to 210 meters wireless transmission range in non-obstacle space
Easy installation and configuration

6
4. Installation Diagram

7
5. Setting up SGZB02I
5.1. Turn On SGZB02I
For power saving, SGZB02I is designed to get into sleeping mode when there is no activity for 2
minutes.To manually turn on SGZB02I, press the Binding Key once.
When SGZB02I is first time used or after resetting →it will try to join the network.
When SGZB02I is in a ZigBee network →it will send out the device data, like IEEE
address/Networkaddress, and the indicator will flash green 5 times. SGZB02I will be activated for 2
minutes.
When SGZB02I was in a ZigBee network, but by any change it is offline →it will start to rejoin
theZigBee network.
5.2. Join the ZigBee Network
After SGZB02I is turned on, it will search for an existing ZigBee network and send a request to join the network
automatically. While SGZB02I is under the coverage from a coordinator or a router whose permit-join feature
isenabled, SGZB02I will be permitted to join the network.
Step1. Enable the permit-join function (valid for 60 seconds) of a coordinator or a router (please refer to
the user manual of the coordinator or the router to enable the permit-join feature).
Step2. Turn on SGZB02I. It will start to search and join the network.
Step3. The indicator will flash green once when it finds out a network to join.
Step4. The indicator will flash green 5 times after it is joined successfully. Otherwise, the indicator will
not flash.
NOTE: After joining the network, SGZB02I will try to enroll in the ZigBee security system. Please keep it
powering on.
5.3. Enroll in the ZigBee Security System
SGZB02I is a Zone device in the ZigBee security system. Right after SGZB02I join the ZigBee network, it will
automatically find out a CIE (Control and Indicating Equipment) device (i.e. ISysmart Z201B) and send a
registration request to the CIE device to enroll in the security system. The enrollment has these 3 situations:
A.
There is no CIE device or no compatible CIE device in the network → the indicator flashes orange
twice.
B.
There is a compatible CIE device in the network, but it is failed to enroll →the indicator flashes
orange 4 times.
C.
The enrollment is completed →the indicator flashes orange 6 times.
NOTE: Users had better NOT enroll multiple Zone devices at the same time to prevent registration failure.

8
5.4. Sleeping Mode
SGZB02I is designed to go into sleeping mode for power-saving in some situations:
A.
When it doesn’t find a network to join → SGZB02I will go to sleeping mode.
B.
While the device is in the network → the sleeping period is 5 minutes; it will wake up every 5
minutes to keep online.
C.
Once SGZB02I was joined to a network and by any chance the network is no longer existed or the
device is out of the network → SGZB02I will wake up every 15 minutes to find the network it
joined before. It never keeps in sleeping mode and continues to find its network every 15 minutes.
This condition would consume up to 30 times power spending compared to normal-operating status.
To prevent this unwanted power consumption, we recommend that users manually power off the
device.
5.5. HeartBeat Technique
In a security system, it is important that Zone devices report the conditions to the central security unit (the
CIE device). To meet this need, ISysmart came up with a technique called “HeartBeat”.
Right after SGZB02I enrolls to a security system, it sends a HeartBeat signal to the CIE device. Afterward, it
willsend HeartBeat data every hour by default settings.
5.6. Battery
Low-power report: When the operating voltage is lower than 2.4V, SGZB02I will send a low-power report to the
CIE device.
The related data:
Power configuration cluster (ID:0x0001)
Battery voltage attribute (ID:0x0020)
5.7. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Remove the batteries to power off SGZB02I.
Step2. Press and hold the Binding Key, then power on SGZB02I to complete the restore.

9
6. Home Automation Clusters for SGZB02I
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by SGZB02I.
1.
End Point(s):0x01:
2.
Device ID:IAS Zone(0x0402)
3.EndPoint Cluster ID
Cluster ID for SGZB02I
Server side
Client side
EP 0x01 (Device ID: IAS Zone(0x0402) )
Basic(0x0000)
None
Power configuration(0x0001)
Identify(0x0003)
IAS zone ( 0x0500)
commissioning( 0x0015)
This lists the attributes of the basic information.
Attributes of the Basic Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
ZCLVersion
Unsigned
8-bit integer
0x00 –
0xff
Read only
0x03
M
0x0001
ApplicationVersion
Unsigned
8-bit integer
0x00 –
0xff
Read only
--
O
0x0002
StackVersion
Unsigned
8-bit integer
0x00 –
0xff
Read only
--
O
0x0003
HWVersion
Unsigned
8-bit integer
0x00 –
0xff
Read only
0x0C
O
0x0004
ManufacturerName
Character
string
0 –32
bytes
Read only
“iSysmart”
O
0x0005
ModelIdentifier
Character
string
0 –32
bytes
Read only
9
“ZB02IE3ED”
O
0x0006
DateCode
Character
string
0 –16
bytes
Read only
--
O
0x0007
PowerSource
8-bit
Enumeration
0x00 –
0xff
Read only
0x03
M

10
0x0010
LocationDescription
Character
string
0 –16
bytes
Read/write
16
Afterwards
0x20
O
0x0011
PhysicalEnvironment
8-bit
Enumeration
0x00 –
0xff
Read/write
0x00
O
0x0012
DeviceEnabled
Boolean
0x00 –
0x01
Read/write
0x01
M

11
7. Important Maintenance Instructions
Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can
contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please
leave the device dry properly before storing or using.
Do not use or store the device in dusty or dirty areas.
Do not use or store the device in extremely hot temperatures. High temperatures may damage the device or
battery.
Do not use or store the device in extremely cold temperatures. When the device warms to its normal
temperature, moisture can form inside the device and damage the device or battery.
Do not drop, knock, or shake the device. Rough handling would break it.
Do not use strong chemicals or washing to clean the device.
Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep your device
operational. For damaged device, please contact the authorized service center in your area.
Table of contents