‘Plug & Play’ quick mounting manual - HD Outside Wash - Various Positions - art.no. HD.RETRO.VAR.2x4
INTRODUCTION
ASSEMBLY GUIDE SYMBOLS
Bolt/screw
Welding
Liquid gasket
(included in package)
Spare gasket rings
for use in the UNDINE®
unit are included.
MAINTENANCE
This is the ‘Plug & Play’ quick mounting manual for the:
IWC/UNDINE® Inline Outside Bird Washer (Chicken)
Type IWC Outside Wash, art.no. HD.RETRO.VAR.2x4
The working principle of this equipment is based on the unique UNDINE® water/air mixing technique.
See for details of this technique our introduction movie at www.iwc-international.com
Installation must be performed by qualified technical personnel familiar with poultry slaughter- and
cleaning systems.
Start by checking all parts are available as mentioned in the part list on the next page.
SPECIFICATIONS
Consumption Pressure
900 - 1400 ltrs/hour 10 barWater
Air 200 ltrs/min 6 - 8 bar
(actual size)
If the water- and airpressure as
advised are not applied,
the equipment may not function in
accordance with your requirements.
IMPORTANT NOTICE
• Check horizontal level
• Prevent heat or burn damage
1. WELD UNIT TO LINE
2. ADJUST ANGLE AND HEIGHT
2x
Always avoid any contact
possibility between the
nozzles and the birds/shackles!
CAUTION
CAUTION