Jadever JWE User manual

0
Chapter
ASSEMBLY············································································ 1
INSTALLATION······································································ 1
PRECAUTIONS······································································ 2
FEATURES············································································· 2
LCD DISPLAY········································································ 3
KEYPAD················································································· 5
FUNCTION SETTING····························································· 6
OPERATION··········································································· 9
WEIGHING UNIT CONVERSION··········································· 12
APPENDIX 1
ERROR MESSAGE ···························································· 12
TROUBLE SHOOTING······················································· 12
APPENDIX 2
RS-232 FORMAT································································ 12
RS-232 OUTPUT SIGNAL·················································· 14

1
Thank you for your purchase of high precision electronic weighing scale;
this scale enables you to measure the quantity, weight and percentage. The
scale is easy to operate, precise, stable and with fast display reaction. It is
applicable in the electronic, hardware, plastic, medicine, textile and various
other industries. It is useful for packaging, inventory and various production
and quality control cases.
※ It could be dangerous by using improper battery or wrong connection of
battery.
ASSEMBLY
INSTALLATION
n Put the weighing pan (1) on the scale (2).
n Always lock the protection screw (3) (30kg mode without protection
screw)before transportation.
n Remove the protection screw(30kg mode without protection screw).
n Power socket (4).
n Power switch (5).
MODEL: JWE
1 weighing pan
2 scale body
3 protection screw
4 power socket
5 power switch

2
PRECAUTION
n Full charge the battery after unpacking the scale.
n Install the equipment on a level and stable surface.
n Do not install the equipment near the air conditioning or
vibrating machinery.
n Install the equipment in a temperature environment within
-5℃—40℃, prevent from rapid temperature changes.
n Independent AC outlet for this equipment is recommended,
check the voltage before plug in.
n Warm up the equipment for 15 minutes before use.
FEATURES
n The microprocessor in this scale features
1) Automatic zero point tracking function.
2) Tare and pre-tare function.
3) HI, LO, OK warning function.
n Easy operating and water-resistant membrane keypad.
n Easy to read backlight LCD display.
n Accumulating function for weight or quantity up to 99 times.
n Counting function is applicable.
n Tare range is unlimited.
n Stainless steel weighing pan is used for long-term operation.

3
LCD DISPLAY
jIndicator for battery .Red means battery needs to be charged.
When the indicator turn green, means that the battery is fully charged.
kLCD display.
lIndicator for accumulation

4
LCD DISPLAY FUNCTION SELECTION PAGE
Calibration 6
↓
.
g
Capacity & resolution 30000/6000 6
↓
k
g
Weigh unit ON/OFF 6
↓
kg Initial weight unit Kg / g / lb / lb-oz / pcs / % 6
↓
Filter 1/2/4/8 7
↓
. Auto power off NO/5/10/30/60 7
↓
. Backlight OFF/ON/AUT 7
↓
. Zero point range 0/1/2/3/4/5 7
↓
. RS-232 baud rate 2400/4800/9600 7
↓
. Printing mode Pr/St/Co 7
↓
External device PC/TPSH/AX/EZ2-S/TDP643 8
↓
External device PC/TPSH/AX/EZ2-S/TDP643 8
↓
Memory ON/OFF 8
↓
. Beep sound Un/In/no/Lo 8

5
KEYPAD
M+
MR
Use this key for accumulation, and to show total
accumulation values.
MC
SET
Use this key to set HI, LOW range, and also to clear
the accumulation
MODE
For switching the weighing units.
TARE
<
Press this while tare subject is on the weighing pan.
ZERO
+
:
Reset to zero.
Remark:◄move the cursor to left
+ add

6
MC
SET
FUNCTION SETTING
Turn the power on while holding down the key.
The scale will go into function setting mode and appears
on the LCD display.
· Press key to switch the function setting.
· Press key to select the functions.
· Press key to end and save the function setting.
Ø The LCD display shows (example: Model JWE-3K)
– press key to select the weighing capacity and resolution .
The capacity and resolution depend on the model of the scale。
Ø TheLCDdisplayshows
– press key to select the applicable weighing unit,
press key to enable (ON) or disable (OFF) the weighing
unit. * At least one of the unit has to be used
。
Ø TheLCDdisplayshows
Indicates that “Kg” is the initial weighing unit when power on.
– press key to change the selection.
.
g
k
g
kg
M+
MR
M+
MR
MODE
M+
MR
MC
SET
M+
MR
ZERO
+

7
Ø TheLCDdisplayshows
– press key to select the filter performance, 1, 2, 4, 8 can be
selected.
Ø TheLCDdisplayshows
– press key to select the time of auto power off, 5, 10, 30, 60
minutes and “NO” can be selected.
Ø TheLCDdisplayshows
– press key to select LCD backlight setting, “ON”, “OFF”, “AUT”
(backlight >9e) can be selected.
Ø TheLCDdisplayshows
– press key to select zero tracking range, 0-5 can be selected.
Ø TheLCDdisplayshows
– press key to select the transmission rate of RS-232 as 2400,
4800 and 9600 bps.
Ø TheLCDdisplayshows
– press key to select the data transmitting mode.
1) Prt.Pr – data sent when key pressed
2) 2) Prt.St – data sent automatically when stable symbol shown
3) Prt.Co – data sent continuously
.
.
.
.
.
M+
MR
M+
MR
M+
MR
M+
MR
M+
MR
M+
MR

8
Ø When LCD display and follow by
press to choose the external device i.e. : PC、TP、SH、AX、
EZ2-S、TDP-643.
Ø TheLCDdisplayshows
– press key to enable (ON) or disable (OFF) the memory
function.
Ø TheLCDdisplayshows
– press key to select beep mode.
Un – beep sounds when load over pre-set value
In – beep sounds when load between pre-set values
no – beep sounds when load over pre-set value 1 or under pre-set
value 2
Lo – beep sounds when load under pre-set value
Remarks:
Press key anytime when a function setting is completed.
This will save the setting and return the scale to normal weighing mode.
Recharge the battery:
When battery symbol appears on the LCD display, plug in AC power for
charging the battery, the indicator will turn red. The charge is complete, when
indicator turns into green, (It takes about 8 hours for charging).
.
M+
MR
M+
MR
ZERO
+
M+
MR

9
OPERATION
u Counting
Press key until LCD display show
then press key, the LCD display shows
press key select the numbers (25, 50, 100) of sampling,
put the samples on the weighing pan, when beep sounds, it is
ready for operation.
u Sampling by percentage
Press keyuntilLCDdisplayshows ,
then press key, the LCD display shows
press key select the percentage (25, 50, 100) of sampling,
put the samples on the weighing pan, when beep sounds, it is
ready for operation.
PCS
PCS
%
MODE
MC
SET
MC
SET
MODE
MC
SET
MC
SET

10
u Hi/Low setting
Press key, then press key, the LCD display shows
,press keytomovetheblinking“0”,press
key to enter the limit of the HI weighing value . Press
keyafterthat,theLCDdisplayshows ,press
keytomovetheblinking“0”,press key to enter the limit
of the LO weighing value Press key again, the Hi, Low setting
are completed and ready for operation. The value of Low must be set
lower then the value of Hi.
Press to cancel Hi/Lo check function.
Remark:
◎When setting is set to “ON”, the Hi/Low values will
be saved in the memory and can be recalled whenever the scale is
on.
◎The and keys are applicable when operation.
.
O
.
O
MC
SET
MODE
TARE
<
ZERO
+
MODE
TARE
<
ZERO
+
MODE
TARE
<
ZERO
+
M+
MR

11
u Accumulation
When there is weight on the pan, press key to accumulate,
the LCD display shows (example: the weighing
unit is g), the maximum of accumulation is 99 data. When “0” shows
on the display, press key, the LCD display shows
the numbers of accumulation. Press key again, to show the
total accumulated weight. When accumulation is over 99 data, the
LCD display shows the new data will be disallowed.
When total accumulation value is over the LCD display range, the LCD
displayshows .Press keytoreturntonormal
weighing mode, or press key to cancel the accumulation and
return to normal weighing mode. It will only clear the accumulation
when the total weight appeared in the display
u Tar e
Place the object on the pan, press key and the weight will be
tare. The display will show . When you want to
cancel the tare weight, remove the object from the pan , the display will
show the tare weight in negative . Then , press key the
display will return to ZERO.
WEIGHING UNIT CONVERSION.
1 lb = 453.59237g
XXXXg
XX
g
g
g
M+
MR
M+
MR M+
MR
M+
MR
MC
SET
TARE
.
TARE
<
TARE
<

12
APPENDIX 1
n Error message
Message Problem
Err2 Initial zero point over+10%
-Err2 Initial zero point less-10%
Err3 Over A/D resolution range FFFFF
-Err3 Less A/D resolution range -XXXXX
Err4 EEPROM Chksum error
Err5 Over load(max. capacity +9e)
Err6 Wrong weighing master when calibration
OuEr1 Accumulation over 99 data
OuEr2 Accumulation value over display range
Battery symbol Low battery
n Trouble shooting
When Error message Trouble shooting
Power on Err2,-Err2 Check and remove the object from weighing
pan or malfunction of LOAD CELL
Power on Err3,-Err3 Check if A/D or LOAD CELL malfunction
Power on Err4, Switch power off and power on again, or do the
calibration
Power on Battery symbol shown Charge the battery with power on
Normal
weighing mode Err5 Check if weighing object over the capacity+9e
Calibration Err6 Change weigh master
APPENDIX 2
RS-232 OUTPUT FORMAT
Baud Rate :2400、4800、9600
Data Bit :8
Parity :N ( None )
Stop Bit :1
Code :ASCII
Bit Format :
LSB MSB
0 1 2 3 4 5 6 7 8 9
Start
Bit Parity
Stop
Bit

13
Data Format:
n kg
G/N . W . :+/- kgCRLF
weight
Example:
G.W. :+ 2.2352kg
N.W. :+ 1.2352kg
n g
G/N . W . :+/- gCRLF
weight
Example:
G.W. :+ 2235.2g
N.W. :+ 1235.2g
n lb
G/N . W . :+/- lbCRLF
weight
Example:
G.W. :+ 2.2352lb
N.W. :+ 1.2352lb
n lb-oz
G/N . W . :+/- -lb oz
CR LF
weight lb Weight oz
Example:
G.W. :+ 3- lb12.235 oz
N.W. :+ 3- lb12.235 oz
n pcs
T o t a l
:+/- p c s CR LF
pcs
Example:
Tota l:+ 645 pcs
n %
+/- %CRLF
pcs
Example:
+ 24%
G = GROSS N = NET

14
RS-232 INPUT FORMAT
Baud Rate :2400、4800、9600
Data Bit :8
Parity :N ( None )
Stop Bit :1
Code :ASCII
Command on computer:‘ R ’ = READ ‘ Z ’ = ZERO ‘ T ’ = TARE
Printer & Printing Format (example: kg)
TP-24 SH-24 EZ2-S AX-III TDP-643
T.W.:
+0.0000 kg
N.W.:
+1.6025 kg
G.W.:
+1.6025 kg
T.W.:
+0.0000 kg
N.W.:
+1.6025 kg
G.W.:
+1.6025 kg
T.W.:+0.0000 kg
N.W.:+1.6025 kg
G.W.:+1.6025 kg
RS-232 Connector
RXD PC to SCALE
TXD1 SCALE to PC
TXD2 SCALE to PC
CONNECTOR DB25
13
25
12
24
11
23
10
22
9
21
8
20
7
19
6
18
5
17
4
16
3
15
2
14
1
Other manuals for JWE
2
Table of contents
Other Jadever Scale manuals

Jadever
Jadever JWI-700W User manual

Jadever
Jadever JCN User manual

Jadever
Jadever JKH User manual

Jadever
Jadever JWE User manual

Jadever
Jadever JCAII User manual

Jadever
Jadever LPWN-1530 User manual

Jadever
Jadever JWA series User manual

Jadever
Jadever JCAII User manual

Jadever
Jadever NWTE User manual

Jadever
Jadever JWL-1.5K User manual

Jadever
Jadever JCL User manual

Jadever
Jadever JCL-3K User manual

Jadever
Jadever JWI 700C User manual

Jadever
Jadever JCL User manual

Jadever
Jadever JC User manual

Jadever
Jadever JKD 250 User manual

Jadever
Jadever LGCN-3075 User manual

Jadever
Jadever JCL Series User manual

Jadever
Jadever SNUGIII Series User manual

Jadever
Jadever IDS701-CTRUCK User manual