Operator Instructions
Introduction
The Smoothie™ pipette filler may be used with glass
or plastic pipettes to facilitate the pipetting of a wide
range of liquids. Pipettes within the volume range of
1ml to 25ml can be used.
When correctly used, the liquid should only come into
contact with the pipette.
Operating Instructions
1. Fitting the pipette
Carefully attach the pipette by inserting it into
the silicone holder inside the nose cone. Do not
use force.
2. Choosing the correct thumb wheel setting
The Smoothie™ is equipped with a rotating
thumb wheel which advances the piston up and
down the barrel for aspiration and dispensing. The
unique thumb wheel can be set at two different
dispense resolutions for maximum accuracy
depending on the volume of liquid being
dispensed. Fast filling for volumes of 10ml to 25ml
is possible when the thumb wheel is positioned to
the right. This is the default setting. Whenever you
are working with pipettes smaller than 10ml we
recommend that you choose the fine setting –
whereby the thumb wheel is positioned to the left.
To change the thumb wheel setting the piston
must be in its lowest position (image 1A). To
change from the default setting to the fine setting
use the thumb of your right hand to push the
thumb wheel by pressing the thumb wheel button
all the way in to the left (image 1B). With your left
hand rotate the fixing button until the gear
locator is locked in its respective groove ( image
1C), thus holding the thumb wheel in its new
position. The thumb wheel should now be
positioned to the left. The pipette is now ready for
work in its fine setting as recommended for
volumes less than10ml.
Image 1. Choose the correct thumb wheel.
A. Piston in low position.
B. Push.
C. Rotate the fixing button.
Image 2. Rotate the thumb wheel to fill
the pipette.
Image 3. Press the dispense lever down to
empty the pipette by gravity.
A.
B.
C.
Jencons Scientific Inc (USA)
800 Bursca Drive, Suite 801
Bridgeville, PA 15017
Phone: 412 257-8861
Toll Free: 800 846-9959
Fax: 412 257-8809
Email: [email protected]
Website: www.jenconsusa.com
Jencons Scientific Ltd
Cherrycourt Way Ind. Est.
Stanbridge Rd, Leighton Buzzard
LU7 4UA, ENGLAND
Phone: 01342 337447
Fax: 01342 337447
Int. Phone: +44 1342 337447
Int. Fax: +44 1342 337474
Email: [email protected]
Int. Email: [email protected]
Website: www.jencons.co.uk
Online sales: www.ecomcat.co.uk
ISO 9001:2000
FM 15114
Piston
Thumb wheel
button
Dispense lever
Fixing button
Nose cone
Thumb wheel
Operator Instructions
3. Filling the pipette
Place the tip of the pipette into the liquid
to be aspirated. With your thumb rotate
the thumb wheel (as shown in image 2)
allowing the liquid to fill the pipette so that
the meniscus is level with the required mark.
Note: Do not allow liquid
to enter the Smoothie™.
4. Dispensing
Hold the receiving vessel in an inclined
position, placing the pipette tip against the
receiving vessel’s wall. Press the dispense lever
down to empty the pipette by gravity (as
shown in image 3).
5. ‘Blow-out’ Pipettes
As soon as the meniscus in the pipette comes
to a standstill, rotate the thumb wheel
upwards to expel the last few drops. To
ensure the complete volume is dispensed,
wipe the pipette tip upwards a few millimetres
along the inside wall of the receiving vessel.
Using your free hand push the piston to its
lowest position. The Smoothie™ is ready for a
new pipetting operation.
Each Smoothie™ is impregnated with a slight
fragrance of the fruit it depicts. The fragrance will
slowly disappear over a 2 month period.

Other JENCONS Laboratory Equipment manuals

JENCONS SAFETYPETTE Specifications

JENCONS

JENCONS SAFETYPETTE Specifications

JENCONS Powerpette Pro Specifications

JENCONS

JENCONS Powerpette Pro Specifications

JENCONS Safetypette Pro Specifications

JENCONS

JENCONS Safetypette Pro Specifications

JENCONS Powerpette Specifications

JENCONS

JENCONS Powerpette Specifications

JENCONS Powerpette Pro Specifications

JENCONS

JENCONS Powerpette Pro Specifications

Popular Laboratory Equipment manuals by other brands

Radleys Carousel 6 Plus instructions

Radleys

Radleys Carousel 6 Plus instructions

Hemotherm 400MR Operation & technical manual

Hemotherm

Hemotherm 400MR Operation & technical manual

mrclab DVO Series Operation manual

mrclab

mrclab DVO Series Operation manual

CoolLED pE-800 quick start guide

CoolLED

CoolLED pE-800 quick start guide

Luminex Guava easyCyte Maintenance Guide

Luminex

Luminex Guava easyCyte Maintenance Guide

IKA A10 basic operating instructions

IKA

IKA A10 basic operating instructions

Belden HIRSCHMANN RPI-P1-4PoE installation manual

Belden

Belden HIRSCHMANN RPI-P1-4PoE installation manual

Koehler K1223 Series Operation and instruction manual

Koehler

Koehler K1223 Series Operation and instruction manual

Globe Scientific GCM-12 quick start guide

Globe Scientific

Globe Scientific GCM-12 quick start guide

Getinge 86 SERIES Technical manual

Getinge

Getinge 86 SERIES Technical manual

CORNING Everon 6000 user manual

CORNING

CORNING Everon 6000 user manual

Biocomp GRADIENT MASTER 108 operating manual

Biocomp

Biocomp GRADIENT MASTER 108 operating manual

Cole Parmer Stuart SB3/1 instruction manual

Cole Parmer

Cole Parmer Stuart SB3/1 instruction manual

BEVS 2501/2A user manual

BEVS

BEVS 2501/2A user manual

Qiagen DML 3000 user manual

Qiagen

Qiagen DML 3000 user manual

Queensgate NANOSCAN OP400 Quick start instructions

Queensgate

Queensgate NANOSCAN OP400 Quick start instructions

Parr Instrument 4560 Operating instructions manual

Parr Instrument

Parr Instrument 4560 Operating instructions manual

Integra DOSE IT operating instructions

Integra

Integra DOSE IT operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.