Judo PROFI-PLUS Series User manual

Installation and operating instructions
JUDO PROFI-PLUS
Backwash protective filter ¾" - 1¼"
Valid for: EU countries and Switzerland
Language: English
Read before use and store!
Installation and operating instructions
JUDO PROFI-PLUS
Backwash protective filter ¾" - 1¼"
Valid for: EU countries and Switzerland
Language: English
Read before use and store!

2 JUDO JPF+ 1701582 • 2018/12
Queries, orders, customer service
JUDO Wasseraufbereitung GmbH
Postfach 380
D-71351 Winnenden
Email: [email protected] • judo.eu
Office address:
JUDO Wasseraufbereitung GmbH
Hohreuschstraße 39 - 41
D-71364 Winnenden
Trademarks:
Trademarks used in this document are the
protected and registered trademarks of the
owners.
© JUDO Wasseraufbereitung GmbH
D-71364 Winnenden
All rights reserved.
Reprinting, even in excerpt form, is only
permitted with special approval.
Dear customers,
Thank you for the confidence you have
shown in us by purchasing this prod-
uct. You have purchased a state-of-the-
art device. It has been carefully checked
prior to delivery. Nevertheless, if diffi-
culties occur, please contact the closest
customer service (see chapter Customer
service).
These installation and operating instruc-
tions are intended for both installers, who
are in charge of installing, maintaining or
repairing the device, and for the operators
of the device.

Contents
1701582 • 2018/12 JUDO JPF+ 3
Contents
1 Safety.................................................. 4
1.1 Intended use........................................4
1.2 Application limits..................................4
1.3 Safety instructions............................... 4
1.4 Symbols used...................................... 6
1.5 Units used............................................6
2 Product information.......................... 6
2.1 Scope of supply...................................6
2.2 Function description.............................6
2.3 Materials used..................................... 7
2.4 Approval marks....................................7
3 Installation.......................................... 8
3.1 Conditions............................................8
3.2 Installation of the rotary flange fit-
ting....................................................... 8
3.3 Installation of the device......................9
3.4 Draining of the backwash water.........10
3.5 Commissioning.................................. 11
4 Operation.......................................... 11
4.1 Cleaning of the sieve insert (backwash-
ing).....................................................11
4.2 Conversions, changes....................... 12
4.3 Maintenance, repair, spare parts....... 13
4.4 Temporary removal of the device...... 13
5 Servicing...........................................13
5.1 Cleaning.............................................13
5.2 Warranty and maintenance............... 13
6 Fault.................................................. 14
7 Technical data..................................15
7.1 Installation dimensions...................... 16
7.2 Accessories........................................16
7.3 Spare parts........................................ 17
8 Disposal............................................ 19
9 Customer service.............................20

Safety
4 JUDO JPF+ 1701582 • 2018/12
1 Safety
These operating instructions must always
be available at the place of use of the
device.
1.1 Intended use
The device is for the
•Filtration
of drinking water in domestic water pip-
ing and for residential, commercial and
industrial use. It removes coarse and fine-
grained particles from the drinking water,
which are larger or equal to the mesh size
of the filter, in order to prevent
•pipe damage caused by corrosion
•malfunctions of fittings or control and
regulating devices caused by foreign
bodies.
The filter is suitable for use in cold drinking
water up to a maximum water temperature
of 30 °C (86 °F). The water to be filtered
must comply with the European Drinking
Water Directive.
The device can be installed in all commer-
cially available drinking water pipes. Both
installation and use of the device are sub-
ject to the applicable national regulations.
INFO_NO_HEADER
Particles that are smaller than the
mesh size of the filter supplied and
materials causing cloudiness cannot
be filtered out of the water.
1.2 Application limits
1.2.1 Water quality
The water to be filtered must comply with
the European Drinking Water Directive.
Before using the device with water that
does not comply with this Directive, it is
essential to consult the manufacturer.
1.2.2 Water pressure
CAUTION
The water pressure must not exceed
16 bar input pressure. The device
must not be installed if the mains
pressure is above 16 bar (even for a
short time)!
Nominal pressure PN 16
Operating pressure 1.5 bar - 16 bar
The water pressure must not fall below
1.5 bar as otherwise backwashing can be
impaired!
INFO_NO_HEADER
Starting at an operating pressure
of 10 bar, increased wear can be
expected!
1.3 Safety instructions
1.3.1 Electrical danger
ELECTRO_NO_HEADER
Risk of electric shock
No electrical wiring or equipment that is
not splash-proof may run or be stored
below the device. Electrical devices/
equipment located in the vicinity of the
device must be splash-proof or comply
with the legal regulations for wet rooms.
1.3.2 Warning of property damage
WARNING
Risk of water damage or damage
to property
The device may only be installed by
qualified technical personnel.
The installation room must be dry and
free from frost.
The ambient temperature must not
exceed 30 °C! In higher temperatures

Safety
1701582 • 2018/12 JUDO JPF+ 5
or direct sunlight, material damage may
occur up to and including breakage of
device parts.
An adequately sized waste water con-
nection (e.g. floor drain) in compliance
with DIN 1986 must be provided.
In order to ensure safe drinking water
hygiene, a free discharge of the waste
water acc. to DIN EN 1717 must be
ensured.
The pipe must be able to safely sup-
port the device (weight: see chapter 7).
If necessary, the pipes must be provided
with additional fastenings or support.
If no bypass valve is installed, a shut-
off valve must be installed upstream of
the unit in order to interrupt the water
supply during installation, maintenance,
repair or malfunction of the device.
Install the device in a vertical position
(± 5°). Otherwise, water may escape and
cause water damage.
For the installation of the device in
domestic water piping, only use the sup-
plied built-in rotary flange (see chapter
3.2).
The flange surface of the rotary flange
fitting must be upright!
The rotary flange fitting must be fitted so
that it is free from mechanical stress or
strain. Otherwise mechanical damage to
the pipe or the rotary flange fitting up to
and including breaks can result.
For proper sealing the profile of the pro-
file flange seal must point towards the
rotary flange fitting (see Figure 2).
Only operate the device in a technically
faultless condition:
•Check for damage prior to installa-
tion.
•Immediately have any malfunctions in
operation rectified by qualified tech-
nical personnel.
Persons who, due to their physical, sen-
sory or mental abilities or their inexperi-
ence or lack of knowledge, are unable to
operate the device safely may not oper-
ate it without supervision or instruction
from a responsible person.
Regular backwashing of the device is
required to ensure safe drinking water
hygiene (see chapter 4.1.1).
Before carrying out a backwash, ensure
that the wastewater connection is func-
tional.
At the end of the backwashing process,
turn the handwheel until it engages so
that no more backwash water escapes.
Otherwise, water may constantly escape
and cause water damage.
Do not use household cleaning agents
to clean the outside of the device, but
only use clear water to avoid embrittle-
ment of the plastic.
The device may only be repaired by
qualified technical personnel.
Only use original spare parts for repairs.
Before performing work on the device
that goes beyond pure operational use,
the device must be depressurised! If
this is ignored, the result may be uncon-
trolled escape of water resulting in water
damage to the building/home.
If the device is removed due to an inter-
ruption of operation:
•Protect the flange surfaces against
damage to ensure proper sealing.
•Protect the device from dirt so as not
to impair drinking water hygiene.
•Store the device in a frost-free place
to prevent damage caused by freez-
ing water and leakage.
Unauthorised conversions and changes
are forbidden for safety reasons. These
can impair the functioning of the device,

Safety
6 JUDO JPF+ 1701582 • 2018/12
leading to leaks and, in the worse case
scenario, to bursting of the device.
1.4 Symbols used
The safety instructions contained in these
operating instructions are labelled with the
following symbols:
Indication of existing dangers
Warning of electric voltage
Torques specified by the manufac-
turer
User tips and other information
Instructions attached directly to the device,
e.g.:
•Direction of flow (arrow)
•Type label
•Cleaning information
must be observed and maintained in legible
condition.
1.5 Units used
Unit Conversion
bar 1 bar = 105 Pa = 0.1 N/mm2
¾" DN 20
1" DN 25
1¼" DN 32
2 Product information
2.1 Scope of supply
•Backwash protective filter, pre-assem-
bled
•Rotary flange fitting
•2 batteries (see chapter 4.1.2)
•Installation and operating instructions
2.2 Function description
Unfiltered water flows into the device
through the rotary flange. A coarse filter
prevents large dirt particles from reaching
the fine filter. The water flows from the out-
side to the inside through a cylindrical sieve
insert. Dirt particles remain on the sieve
fabric of the sieve insert. The adhering
residues are visible from outside through
the transparent filter bowl.
Subsequently the filtered water exits the
device again via the rotary flange fitting.

Product information
1701582 • 2018/12 JUDO JPF+ 7
Fig. 1: Functional description
1 Reset key
2 Handwheel lid with battery compartment for backwash reminder alarm
3 Handwheel for backwashing
4 Adjusting ring for the next backwash date
5 Transparent filter hood
6 Built-in rotary flange
7 Backwashing valve
2.3 Materials used
The materials used are resistant to the
physical, chemical and corrosive loads
expected to be encountered in drinking
water. They meet the requirements speci-
fied in the following standards:
•DIN EN 13443-1
•DIN 19628
•DIN 50930-6
All materials are hygienically and physi-
ologically harmless and fulfill the require-
ments and directives of the Umweltbunde-
samt (UBA). Plastics fulfil the requirements
of DIN EN 16421.
2.4 Approval marks
The device complies with the technical
regulations for drinking water installation
according to DIN EN 806ff. and the national

Installation
8 JUDO JPF+ 1701582 • 2018/12
supplement DIN 1988ff. as well as DIN EN
1717.
It has been tested and certified by the
DVGW (Deutsche Vereinigung des Gas-
und Wasserfaches e. V. - Technisch-wis-
senschaftlicher Verein) in accordance with
the requirements
• of the DIN EN 13443-1 and DIN 19628
for mechanically active filters.
The device bears the DVGW mark as proof
of certification.
INFO_NO_HEADER
Only devices with a standard sieve
mesh width of 0.1 mm carry the
DVGW test mark. Devices with
the available special mesh widths
0.03 mm, 0.32 mm and 0.5 mm
are not part of the test according to
DIN EN 13443-1 and DIN 19628 and
are therefore not permitted to wear
the approval mark.
3 Installation
CAUTION
The device may only be installed
by qualified technical personnel.
Installation of the device upstream of the
water meter is forbidden.
3.1 Conditions
CAUTION
Risk of property damage or water
damage!
The pipe must be able to safely
support the device (weight: see
chapter 7). If necessary, the pipes
must be provided with additional
fastenings or support.
To ensure convenient operation and main-
tenance of the device, always adhere to the
specified clearances in chapter 3.4.1.
3.1.1 Requirements for the place of
installation
CAUTION
The installation room must be dry
and free from frost.
The ambient temperature must not
exceed 30 °C! In higher temper-
atures or direct sunlight, mater-
ial damage may occur up to and
including breakage of device
parts.
An adequately sized waste water
connection (e.g. floor drain) in
compliance with DIN 1986 must be
provided.
3.2 Installation of the rotary
flange fitting
CAUTION
The flange surface of the rotary
flange fitting must be upright!
The rotary flange fitting must
be fitted so that it is free from
mechanical stress or strain. Oth-
erwise mechanical damage to the
pipe or the rotary flange fitting up
to and including breaks can result.
The built-in rotary flange serves as a con-
necting element between the domestic
water station and the device. It is suitable
both for horizontal and vertical pipes.
Attention: Install the built-in rotary flange
in the flow direction! This is indicated by an
arrow integral with the casting.
INFO_NO_HEADER
If the installation is twisted, back-
washing the device is not possible.

Installation
1701582 • 2018/12 JUDO JPF+ 9
1
2
Fig. 2: Rotary flange fitting
1 Profile flange seal
2 Flow direction arrow
3.3 Installation of the device
CAUTION
The pipe must be able to safely
support the device (weight: see
chapter 7). If necessary, the pipes
must be provided with additional
fastenings or support.
If no bypass valve is installed, a
shut-off valve must be installed
upstream of the unit in order to
interrupt the water supply during
installation, maintenance, repair or
malfunction of the device.
Install the device in a vertical posi-
tion (± 5°). Otherwise, water may
escape and cause water damage.
For the installation of the device
in domestic water piping, only use
the supplied built-in rotary flange
(see chapter 3.2).
The flange surface of the rotary
flange fitting must be upright!
For proper sealing the profile of
the profile flange seal must point
towards the rotary flange fitting
(see Figure 2).
1
2
Fig. 3: Attach and engage appliance
1 Insert screws
2 Turn clockwise to engage screws
Fig. 4: Connection of appliance
engaged
Do not undo the screws of the device!
1. Insert the heads of the four flange
screws through the bayonet holes on the
rotary flange fitting (see Figure 3).
2. Turn the device in clockwise direction up
to the stop (see Figure 3 and Figure 4).
3. Tighten the four flange screws.
UNIT
Select the tightening torque (approx.
4 Nm) so that the seal is effective
and the device is not damaged or
strained!

Installation
10 JUDO JPF+ 1701582 • 2018/12
3.4 Draining of the backwash
water
CAUTION
An adequately sized waste water
connection (e.g. floor drain) in
compliance with DIN 1986 must be
provided.
In order to ensure safe drink-
ing water hygiene, a free dis-
charge of the waste water acc. to
DIN EN 1717 must be ensured.
The drain must be large enough so that all
of the waste water can be drained simulta-
neously.
If a waste water connection directly beneath
the filter is not possible, the backwash
water can be drained away via a hose or a
pipe that is connected from the backwash-
ing water valve over a few meters to the
closest waste water connection. The dimen-
sioning of this pipe must correspond to the
backwashing water valve.
If a bucket is used to drain off the back-
wash water:
•Attention: If the mains pressure is high,
water may spray out of the bucket. Pro-
tect objects near the bucket from water
damage!
•Carry out the backwashing quickly and
finish the backwashing process as soon
as the bucket is half full. Otherwise the
bucket could overflow.
3.4.1 Drainage options for the
backwash water

Installation
1701582 • 2018/12 JUDO JPF+ 11
3.5 Commissioning
Prior to initial commissioning (or to com-
missioning after maintenance work) fill the
installed device with water and vent:
1. Open the upstream shut-off valve to fill
the device with water. The device is now
under mains pressure.
2. Attention: Carry out a backwashing
immediately so that the trapped air can
escape (see chapter 4.1.3)! This pre-
vents damage to the installation by
water hammer pressure surges.
After backwashing, the device is vented
and ready for operation.
3.5.1 Insert batteries
The backwash reminder alarm requires two
1,5 V Micro batteries.
How to insert the supplied batteries:
1. Lift the handwheel lid.
2. Insert the two batteries into the battery
compartment.
3. Replace the handwheel lid.
4. Test the functionality of the batteries py
pressing the Reset-button:
°clearly audible beep: batteries are
powerful.
°no beep or only weakly audible:
capacity of the batteries exhausted or
insufficient.
4 Operation
4.1 Cleaning of the sieve insert
(backwashing)
A regular cleaning process is necessary to
remove the residues from the sieve fabric
of the device. This process is called back-
washing.
Suction pipes are provided for backwash-
ing, which rotate around the sieve fabric
of the fine filter. The backwashing valve
opens on the bottom side of the device.
By reversing the water flow from inside to
outside, deposits on the sieve fabric are
carried away and rinsed out with the back-
wash water. The suction pipes also clean
the inside of the transparent filter bowl with
wiper lips during their movement.
The degree of contamination and cleaning
process can be observed from the outside.
INFO_NO_HEADER
The device is backwashed with
filtered water. The filtered water
supply of the domestic installation
remains intact during the backwash-
ing process. No dirty water can reach
the pure water side during the back-
washing.
4.1.1 Backwashing interval
If cleaning is not performed soon enough,
the result may be damage to the sieve
insert. Large quantities of filtered particles
can deform the sieve fabric and in extreme
case lead to tearing of the sieve fabric.
In addition, larger deposit quantities can
impair the backwashing function mechani-
cally.
According to DIN EN 13443-1 backwashing
the device is required at the latest every six
months.
The manufacturer requires a backwash-
ing:
•at least every 2 months
•if the water pressure drops
•if the filter is visibly dirty
Experience has shown that new installa-
tions in the early stages of installation lead
to increased dirt deposits. In this case, a
more frequent backwashing is necessary.
4.1.2 Due date of backwashing
Every two months, a beep reminds you that
the backwashing is due.

Operation
12 JUDO JPF+ 1701582 • 2018/12
To switch off the beep, press the reset but-
ton on the handwheel cover.
By pressing the button, the time interval
of 2 months is restarted.
After backwashing, turn the setting ring
on the front of the device to the next back-
washing due date, as a reminder.
The signal is just an additional reminder
of the necessary backwashing. Indepen-
dant from this signal, the backwashing
interval indicated in chapter 4.1.1 must be
observed.
Check backwash reminder alarm
Press the reset button for at least 3 sec-
onds:
•Beep: the backwash reminder alarm
works. The batteries still have enough
capacity.
•No beep: replace the batteries by new
leak-proof batteries.
This battery test has no influence on the
backwashing interval.
Replace batteries of the backwash
reminder alarm
1. Remove the handwheel cover.
2. Replace the batteries in the battery com-
partment by new ones of the same type
(size 1.).
3. Refit the handwheel cover.
4. Press the reset button on the handwheel
cover for at least 3 seconds. The time
interval of two months is restarted.
Attention: do not dispose of used batter-
ies with the household waste, but in accor-
dance with the local waste disposal regula-
tions.
4.1.3 Backwashing
WARNING
Persons who, due to their phys-
ical, sensory or mental abilities
or their inexperience or lack of
knowledge, are unable to operate
the device safely may not operate
it without supervision or instruc-
tion from a responsible person.
Before carrying out a backwash,
ensure that the wastewater con-
nection is functional.
At the end of the backwashing
process, turn the handwheel until
it engages so that no more back-
wash water escapes. Otherwise,
water may constantly escape and
cause water damage.
1. Turn handwheel counter-clockwise up to
stop. Backwashing water escapes.
2. Turn handwheel clockwise up to stop.
Ensure that no water escapes.
The backwashing process is completed
(see chapter 4.1).
4.2 Conversions, changes
WARNING
Unauthorised conversions and
changes are forbidden for safety
reasons. These can impair the
functioning of the device, leading
to leaks and, in the worse case
scenario, to bursting of the device.

Operation
1701582 • 2018/12 JUDO JPF+ 13
4.3 Maintenance, repair,
spare parts
WARNING
The device may only be repaired
by qualified technical personnel.
Only use original spare parts for
repairs.
Before performing work on the
device that goes beyond pure
operational use, the device
must be depressurised! If this is
ignored, the result may be uncon-
trolled egress of water result-
ing in water damage to the build-
ing/home.
4.4 Temporary removal of the
device
WARNING
If the device is removed due to an
interruption of operation:
•Protect the flange surfaces
against damage to ensure proper
sealing.
•Protect the device from dirt so
as not to impair drinking water
hygiene.
•Store the device in a frost-free
place to prevent damage caused
by freezing water and leakage.
When recommissioning the device, proceed
as with a new installation.
5 Servicing
5.1 Cleaning
CAUTION
Do not use household cleaning
agents to clean the outside of the
device, but only use clear water to
avoid embrittlement of the plastic.
5.2 Warranty and maintenance
Prerequisite for obtaining the statutory war-
ranty claim is regular backwashing (see
chapter 4.1). The DIN EN 13443-1 pre-
scribes that the backwashing must take
place every six months. JUDO however
recommends to comply with the information
in chapter 4.1.1 Backwashing interval.
To ensure the process operates success-
fully as long as possible, regular inspec-
tion and routine servicing of the device are
essential. Where home automation is con-
cerned, this is governed by DIN EN 806-5.
We recommend the conclusion of a main-
tenance contract, which is the best way
to ensure a good operating function, even
beyond the warranty period. The skilled
tradesmen or the factory customer service
are suitable partners for regular mainte-
nance work and the supply of consumables
and wear materials as well as for possible
repairs.

Fault
14 JUDO JPF+ 1701582 • 2018/12
6 Fault
Fault Possible cause Remedy
Backwash
valve is not fully
closed.
Backwash water
continues run-
ning.
Dirt in backwash
valve.
Repeat backwashing and then turn the handwheel
fully home to the stop.
Water flow
decreases.
Sieve clogged. Perform backwashing.
There are leaks
in the filter bowl.
Damaged seals. Inform the installer or the closest customer service
point.
Filter bowl
becomes
clouded.
Hairline cracks
on the filter
bowl.
Filter bowl was
exposed to high
temperatures or
solvents.
•Inform the installer or the closest customer ser-
vice point.
•If water escapes, close shut-off valves. Have the
filter bowl replaced immediately.
The down-
stream pressure
increases slowly
at zero flow.
Inadmissi-
ble pressure
increase due to
process water
heating.
Check the safety relief valve of the warm water boiler.
Inform the installer or the closest customer service
point.
Troubleshooting

Technical data
1701582 • 2018/12 JUDO JPF+ 15
7 Technical data
Backwash protective filter JUDO PROFI-PLUS ¾" - 1¼" JPF+ ¾" - 1¼"
The water to be filtered must comply with the European Drinking Water Directive.
Information about: JPF+ ¾" JPF+ 1" JPF+ 1¼"
Pipe connection ¾" 1" 1¼"
Backwashing volume flow1) 0,2 - 0,4 L/s 0,2 - 0,4 L/s 0,2 - 0,4 L/s
Nominal pressure PN 16 PN 16 PN 16
Operating pressure 1,5 - 16 bar 1,5 - 16 bar 1,5 - 16 bar
Rated flow after backwashing with
a pressure loss of 0,2 (0,4) bar 4,1 (6,7) m³/h 4,7 (7,6) m³/h 5,3 (8,5) m³/h
Mesh size2)
sieve insert 0.1 mm 0.1 mm 0.1 mm
Water temperature and ambient
temperature max. 30 °C max. 30 °C max. 30 °C
Threaded connection according to DIN EN 10226-1
Weight 2,6 kg 2,7 kg 3,3 kg
Order no. 8010072 8010073 8010074
1) Applies to a fully opened backwashing valve and 2 - 3 bar mains pressure.
2) Standard mesh size
Available special sieve mesh sizes (0.03 mm, 0.32 mm and 0.5 mm) for the industrial
use are not part of the testing acc. to DIN EN 13443-1 and DIN 19628 and therefore can
not bear the DIN-DVGW mark.

Technical data
16 JUDO JPF+ 1701582 • 2018/12
7.1 Installation dimensions
Fig.: JPF+ ¾" - 1¼"
JPF+ ¾" JPF+ 1" JPF+ 1¼"
A180 195 230
B130 130 130
C280 280 280
D165 165 165
E165 165 170
F100 100 105
G40 40 40
G1 14 14 14
A Installation length
B Unit depth
C Height above the pipe middle
D Height below the pipe middle
E Installation depth up to the pipe middle
F Waste water connection up to the pipe
middle
G Waste water nominal diameter
G1 Waste water nominal diameter (alterna-
tive)
7.2 Accessories
•Expansion QUICKSET JQR (order no.
8250041) for series connection of two
devices, e.g. filter and water treatment
plant
•PRO-SAFE leak protection (order
no. 8140011)
•Safety block JSB (Best.-Nr. 8735260)
for retrofitting the filter with pressure
reducer, non-return valve, inlet and out-
let pressure manometer

Technical data
1701582 • 2018/12 JUDO JPF+ 17
7.3 Spare parts
JPF+ ¾" - 1¼"

Technical data
18 JUDO JPF+ 1701582 • 2018/12
Pos. Designation Pcs Order
No.
AU1)/
Pc
A Wearing parts set “Sieve 0.1 mm and suction pipe” ***
(consisting of pos. 15, 19, 20, 21)
1 2021359 166
B Wearing parts set “Gaskets” ***
(consisting of pos. 13, 16, 17, 18, 20, 21, 24, 26)
1 2010335 42
C Spare parts set “Backwash reminder alarm”
(consisting of pos. 1, 2, 3)
1 2010495 49
1 Handwheel lid 1
2 Backwash reminder alarm 1
3 Battery 1,5 V type AAA (set with 2 pcs) 1 2060347 8
4 Countersunk screw M5×12 1
5 Disc A 6,4 1
6 Backwash reminder alarm 1
7 Adjusting ring 1
8 Sheet metal screw 3,5×13 4
9 Top of housing JPF+ ¾" 1 2010395 41
9 Top of housing JPF+ 1" 1 2010396 41
9 Top of housing JPF+ 1¼" 1 2010397 41
10 Cylinder screw M6×40 6
11 Flange ring 1
12 Filter bowl 1 2010424 149
13 O-ring 10×3 2
14 Driver 1 2010146 53
15 Driver complete 1
16 Driver 3
17 Suction pipe gasket 1
18 Sheet metal screw 2,9×9,5 1
19 Sieve insert 0,1 mm 1
20 O-ring 90×4 1
21 O-ring 6,3×2,4 1
List of spare parts JPF+ ¾" - 1¼"

Technical data
1701582 • 2018/12 JUDO JPF+ 19
Pos. Designation Pcs Order
No.
AU1)/
Pc
22 Filter bottom 1
23 Hexagonal nut M6 10
24 Profile flange gasket 1 2250219 6
25 Cylinder screw M6×25 (set with 4 pcs) 1 2060446 2
26 O-ring 6,5×6 1
27 Hose connection piece 1
28 Cover 1
29 Filter funnel 1
List of spare parts JPF+ ¾" - 1¼"
1) AU = Accounting unit (items without AU are only available as part of a set)
Replacement interval: *** = 3 years **** = 4 years
8 Disposal
Packaging waste is to be sent to the local
recycling system.
To protect environment, old appliances
must not be disposed of with household
waste. Instead, use the local collection and
return points, which are committed to free
and environmentally sound disposal.

Customer service
20 JUDO JPF+ 1701582 • 2018/12
9 Customer service
DE
JUDO Wasseraufbereitung GmbH
Postfach 380 • D-71351 Winnenden
Phone +49 (0)7195 / 692-0
E-mail: [email protected] • judo.eu
AT
JUDO Wasseraufbereitung GmbH • Niederlassung Österreich
Zur Schleuse 5 • A-2000 Stockerau
Phone +43 (0)22 66 / 6 40 78 • Fax +43 (0)22 66 / 6 40 79
E-mail: [email protected] • judo-online.at
CH
JUDO Wasseraufbereitung AG
Industriestrasse 15 • CH-4410 Liestal
Phone +41 (0)61 906 40 50 • Fax +41 (0)61 906 40 59
E-mail: [email protected] • judo-online.ch
BENELUX
JUDO Wasseraufbereitung GmbH • Filiaal - Filiale BeNeLux
Laarbeeklaan - Av. du Laerbeek, 72 A1 • B-1090 Brussel-Bruxelles
Phone +32 (0)24 60 12 88 • Fax +32 (0)24 61 18 85
E-mail: [email protected] • judo.eu
FR
JUDO France SARL
76 Rue de la Plaine des Bouchers (Technosud) • F-67100 Strasbourg
Phone +33 (0)3 88 65 93 94 • Fax +33 (0)3 88 65 98 49
E-mail : [email protected] • judo.fr
Installed by:
All pictorial, dimensional and implementation information correspond to the date of going
to press. We reserve the right to make changes due to technical progress and continuing
development. Model and product claims cannot be lodged.
This manual suits for next models
3
Table of contents
Other Judo Water Dispenser manuals

Judo
Judo QUICKSOFT-UNO User manual

Judo
Judo QUICKSOFT MEGA 6 User manual

Judo
Judo i-soft@home 5 User manual

Judo
Judo JUDOMAT JM 4 WZ-P User manual

Judo
Judo i-soft TGA 4 User manual

Judo
Judo i-soft@home User manual

Judo
Judo QUICKSOFT-UNO User manual

Judo
Judo JPK 3 User manual

Judo
Judo QUICKSOFT-DUO User manual

Judo
Judo QUICKSOFT MEGA 4 User manual