manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. kelda
  6. •
  7. Bathroom Fixture
  8. •
  9. kelda 93001000 User manual

kelda 93001000 User manual

This manual suits for next models

3

Other kelda Bathroom Fixture manuals

kelda BubbleSpa 95005000 User manual

kelda

kelda BubbleSpa 95005000 User manual

kelda 95001000 User manual

kelda

kelda 95001000 User manual

kelda 24016 Guide

kelda

kelda 24016 Guide

kelda 91017100 Guide

kelda

kelda 91017100 Guide

kelda 93011100 Guide

kelda

kelda 93011100 Guide

kelda 95001000 Guide

kelda

kelda 95001000 Guide

Popular Bathroom Fixture manuals by other brands

Kohler Mira Sport Max J03G Installation and user guide

Kohler

Kohler Mira Sport Max J03G Installation and user guide

Moen 186117 Series installation guide

Moen

Moen 186117 Series installation guide

Hans Grohe Raindance Showerpipe 27235000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Raindance Showerpipe 27235000 Instructions for use/assembly instructions

Signature Hardware ROUND SWIVEL BODY SPRAY 948942 Install

Signature Hardware

Signature Hardware ROUND SWIVEL BODY SPRAY 948942 Install

fine fixtures AC3TH installation manual

fine fixtures

fine fixtures AC3TH installation manual

LIXIL HP50 Series quick start guide

LIXIL

LIXIL HP50 Series quick start guide

KOLO ATOL PLUS installation manual

KOLO

KOLO ATOL PLUS installation manual

Hans Grohe PuraVida 15073000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe PuraVida 15073000 Instructions for use/assembly instructions

Toto TS111B8 Installation and owner's manual

Toto

Toto TS111B8 Installation and owner's manual

Kohler K-1158-H2 Homeowner's guide

Kohler

Kohler K-1158-H2 Homeowner's guide

Coram Showers OFFSET QUADRANT manual

Coram Showers

Coram Showers OFFSET QUADRANT manual

baliv DU-2010 manual

baliv

baliv DU-2010 manual

odass OD-1710 instruction manual

odass

odass OD-1710 instruction manual

Oxygenics Evolution Easy installation instructions

Oxygenics

Oxygenics Evolution Easy installation instructions

Bradley Express SS Series installation instructions

Bradley

Bradley Express SS Series installation instructions

Helvex TH-974 installation guide

Helvex

Helvex TH-974 installation guide

DURAVIT C.1 C15240 0090 Instructions for mounting and use

DURAVIT

DURAVIT C.1 C15240 0090 Instructions for mounting and use

Sunshower PURE SOLO manual

Sunshower

Sunshower PURE SOLO manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Commercial Shower Panel – High E󰀩ciency - Stainless Steel
Fixed Head - Timed Flow ..............................................93001000
Fixed Head - Timed Flow Thermostatic ........................93002000
Flex Head - Timed Flow ..............................................93003000
Flex Head - Timed Flow Thermostatic ........................93004000
Important
Installer — This product manual is the property of the customer and must be retained with the product for
maintenance and operational purposes
Part No. 24011
Issue: Feb 2021
Installation Manual
2
Table of Contents
Important safety information
Description
System diagram
Specications
Siting the shower
Panel Installation
Electrical installation
Factory settings
Troubleshooting
Operation
Maintenance/Cleaning
Spare parts
Customer care
3 -
4 -
5 -
7 -
9 -
10 -
11 -
12 -
13 -
13 -
14 -
17 -
19 -
SYSTEM DESCRIPTION
High E󰀩ciency - Fixed Head - Stainless Steel - Timed
Flow: 93001000
Surface mounted stainless steel panel shower with a
chrome plated xed shower head and Kelda’s patented
water saving technology within. Runs from a blended
water supply (mixer not included), adjustable timed ow is
activated by a digital push button.
High E󰀩ciency - Fixed Head - Stainless Steel - Timed
Flow Thermostatic : 93002000
Surface mounted stainless steel panel shower with a
chrome plated xed shower head and Kelda’s patented
water saving technology within. Includes TMV3 thermo-
static temperature control, adjustable timed ow is activat-
ed by a digital push button.
High e󰀩ciency - Flex Head - Stainless Steel - Timed Flow:
93003000
Surface mounted stainless steel panel shower with a
chrome plated adjustable shower head and Kelda’s
patented water saving technology within. Runs from a
blended water supply (mixer not included), adjustable
timed ow is activated by a digital push button.
High e󰀩ciency - Flex Head - Stainless Steel - Timed Flow
Thermostatic: 93004000
Surface mounted stainless steel panel shower with a
chrome plated adjustable shower head and Kelda’s
patented water saving technology within. Includes TMV3
thermostatic temperature control, adjustable timed ow is
activated by a digital push button.
FLOW VOLUME REGULATION
Flow volume l/m is controlled via a ow regulator
(see system diagram)
The last digit of the product code will designate the ow
regulator pre-tted E.g.
93001004:
High E󰀩ciency - Fixed Head - Timed Flow - 4 l/m
93001005:
High E󰀩ciency - Fixed Head - Timed Flow - 5 l/m
93001006:
High E󰀩ciency - Fixed Head - Timed Flow - 6 l/m
3
Important Safety Information
This product is not a substitute for a shower control (Mixer/
valve) unless TMV3 Mixer model is specied.
This product is not an electric shower.
Products manufactured by Kelda Technology are safe and
without risk provided they are installed, used and maintained
in good working order in accordance with our instructions and
recommendations.
DO NOT operate the unit if the shower head becomes
damaged.
DO NOT restrict ow out of shower by placing an obstruction in
front of the shower head nozzles.
GENERAL
1 . Read all of these instructions and retain them for later use.
2 . DO NOT take risks with plumbing or electrical equipment.
3. Isolate electrical and water supplies before proceeding with
the installation.
4 . The shower panel unit must be mounted onto the nished
wall surface (on top of the tiles). DO NOT tile up to or seal
around ANY PART of the shower panel after installation.
5. The shower head must be cleaned regularly with descalent
to remove scale and debris. The Air hoses must be cleaned
periodically to maintain performance and hygiene. PLEASE
SEE MAINTENANCE SECTION.
6 . This product is not suitable for mounting into steam rooms
or steam cubicles.
7. The shower panel should not be installed in an outdoor
environment, including sheltered areas.
PLUMBING
1 . The plumbing installation must comply with water
regulations, building regulations or any particular
regulations as specied by local water company or
water undertakers and should be in accordance with BS
EN 806 (Specications for installations inside buildings
conveying water for human consumption. Operation and
maintenance).
2 . IMPORTANT! The supply pipe must be ushed to clear
debris before connecting to the shower head water inlet.
3. DO NOT solder pipes or ttings within 300mm of the
supplied hoses, as heat can transfer along the pipework
and damage components.
4 . DO NOT use excessive force when making connections to
the exible hose, solenoid or mixer.
5. All plumbing connections must be completed before
making the electrical connections.
6 . Water pressure. Kelda products are designed to operate
between 1 bar and 5 bar, if you wish to operate outside of
this please discuss with a Kelda Engineer.
ELECTRICAL
1 . The installation must comply with BS 7671 ‘Requirements
for electrical installations’ (IEE wiring regulations), building
regulations or any particular regulations as specied by the
local electrical supply company.
2 . In accordance with ‘The Plugs and Sockets etc. (Safety)
Regulations 1994’, this appliance is intended to be
permanently connected to the xed wiring of the electrical
mains system.
3. Make sure all electrical connections are tight to prevent
overheating.
4 . A 32A 30 mA Residual Current Breaker Operator (RCBO)
MUST be installed in all UK electric and pumped shower
circuits. This may be part of the consumer unit or a
separate unit.
5. Other electrical equipment i.e. extractor fans, pumps must
not be connected to the circuits within the unit.
6 . Each shower must be connected to a 3A switched fused
spur which is easily accessible by maintenance sta󰀨.
Switch o󰀨 at fused spur for maintenance or if not in use for
extended periods. This is a safety procedure recommended
with all electrical appliances.
7. As with all electrical appliances it is recommended to
have the shower and installation checked at least every
two years by a competent electrician to ensure there is no
deterioration due to age and usage.
Contact Customer Service (see back page), if any of the
following occur:
a) If it is intended to operate the shower at pressures
above the maximum or below the minimum stated.
b) If the unit shows a distinct change in performance.
4
Description
Low voltage electricity supply
Shower head
Digital switch with LED indicator
Solenoid and ow reducer
Control Hub
Flow Sensor
Water pipe
Air pipe
Timed Flow
(93001000 / 93003000)
Blended water connection point, ½”BSP at
solenoid or extend with supplied 750mm
exible hose with 15mm pusht connection
Flow Regulator Installation
Correct orientation Incorrect orientation
Timed FlowThermostatic
(93002000/ 93004000)
TMV3 Mixer
Hot and cold water connection points,
½”BSP compression ttings or extend with
supplied 800mm exible hose with 15mm
pusht connection
5
System Diagram
Hot/Cold water feed (Bottom)
Optional route Low voltage
electrical link (Back)
Timed Flow Thermostatic (93002000 / 93004000)
32A RCBO
Ceiling Void Area
Cubicle AreaRear Void Area
Low voltage 36v Electrical
link
TMV3 Mixer/Valve
220-240V Mains electricity
supply via the LPV
150W-36V AC Transformer
(supplied)
Digital switch control
and LED indicator
Optional route Hot/Cold
water feed (Rear)
Hot/Cold Feed Entry Points
Bottom / Bottom Rear
Hot/Cold Feed Entry
Points, Top
Timed FlowThermostatic
(93002000/ 93004000)
6
Timed Flow Thermostatic (93002000 / 93004000)
2
You should have the following assemblies within your High e󰀩ciency Commercial Panel order:
Panel
Specication
222mm
1110mm
218mm
86mm
x4 TX20
Fixing Points
103mm 127mm
OR
x1 Bright chrome
shower head
x1 LPV 150-36v Power Supply
x1 Mixer Allen Key (5mm) x1 Torx Allen Key (T25)
x1 Fixing Kit: (x4 Screws, x4 Rawl plugs)
x1 Grommet selection
Installation
3
142mm140mm
1Shower Head
7
System Diagram
Timed Flow (93001000 / 93003000)
32A 30mA RCBO
Blended water feed (Bottom)
Optional route Low voltage
electrical link (Bottom Rear)
Cubicle AreaRear Void Area
Digital switch control
and LED indicator
Optional route Blended
water feed (Rear)
Low voltage 36v Electrical
link
220-240V Mains electricity supply
via the LPV
150W-36V AC Transformer
(supplied)
Ceiling Void Area
Optional route Blended
water feed (Top Rear)
Blended water feed (Top)
Blended Feed Entry
Points, Top
Blended Feed Entry Points
Bottom / Bottom Rear
8
Timed Flow (93001000 / 93003000)
You should have the following assemblies within your High e󰀩ciency Commercial Panel order:
2Panel
Specication
222mm
218mm
86mm
x4 TX20
Fixing Points
1110mm
x1 LPV 150-36v Power Supply
x1 Torx Allen Key (T25)
x1 Fixing Kit: (x4 Screws, x4 Rawl plugs)
x1 Grommet selection
Installation
3
103mm 127mm
OR
x1 Bright chrome
shower head
142mm140mm
1Shower Head
9
Siting the Shower
Fixed Head 93001000/93002000 Flex Head 93003000/93004000
Tools needed for the job
Warning!
!• When the Control Hub is installed, the RCBO switch must be within easy reach.
• Do not use extensions or multiple sockets
• The power supply cable must never be bent or dangerously compressed
2100mm
2000mm
1950mm
1850mm
Installation should be completed to suit the user’s
requirements.
Installation should be completed to suit the user’s
requirements.
Min/Max
Area to
install
shower head
Min/Max
Area to
install
shower head
T25 Security Torx
(Pin Torx)
10
Installation
Panel
Remove the front cover by unscrewing the 4 M3 TX20 screws.
Using the shower xing bracket, mark and drill holes for
shower xing bracket on the back of the shower cubicle and
secure bracket using the rawl plugs and screws supplied.
1
Connect blended water feed either directly to ½”BSP Solenoid
connection, or use ex hose provided with 15mm push t connection.
For thermostatic panel connect hot and cold feeds to TMV3
mixer ½”BSP compression ttings, ex hose extensions
are supplied with 15mm push t connections. See TMV3
mixer instructions for commissioning and servicing details.
2
Take care to ensure cables and pipes are not pinched
when front panel is tted. Secure front panel with 4 x
Tx25 screws (supplied Tx25 Allen key can be used). For
thermostatic panel t control handle with Allen key provided.
3 4
Run the low electrical power cable from the power
supply,protected by 32A 30mA RCBO and 3A switched fused
spur in compliance with all IEEE standards and local building
standards and regulations, to the control hub. See ELECTRICAL
INSTALLATION for connecting power supply cable to hub.
!
Remember!
Always check for hidden pipes + cables before drilling.
Warning: Run water through plumbing to clear debris from pipework before connecting to Kelda panel. Take
caution when removing the front cover as the Digital push button is attached to the Control Hub with a cable.
190mm horizontal
mounting holes
Mixed
water feed
connection
1000mm vertical
mounting holes
Hot and
Cold supply
connections
Timed Flow
(93001000 / 93003000)
Timed FlowThermostatic
(93002000/ 93004000)
Cold feed 15mmHot feed 15mm
150mm
Centres