3
Important Safety Information
This product is not a substitute for a shower control (Mixer/
valve) unless TMV3 Mixer model is specied.
This product is not an electric shower.
Products manufactured by Kelda Technology are safe and
without risk provided they are installed, used and maintained
in good working order in accordance with our instructions and
recommendations.
DO NOT operate the unit if the shower head becomes
damaged.
DO NOT restrict ow out of shower by placing an obstruction in
front of the shower head nozzles.
GENERAL
1 . Read all of these instructions and retain them for later use.
2 . DO NOT take risks with plumbing or electrical equipment.
3. Isolate electrical and water supplies before proceeding with
the installation.
4 . The shower panel unit must be mounted onto the nished
wall surface (on top of the tiles). DO NOT tile up to or seal
around ANY PART of the shower panel after installation.
5. The shower head must be cleaned regularly with descalent
to remove scale and debris. The Air hoses must be cleaned
periodically to maintain performance and hygiene. PLEASE
SEE MAINTENANCE SECTION.
6 . This product is not suitable for mounting into steam rooms
or steam cubicles.
7. The shower panel should not be installed in an outdoor
environment, including sheltered areas.
PLUMBING
1 . The plumbing installation must comply with water
regulations, building regulations or any particular
regulations as specied by local water company or
water undertakers and should be in accordance with BS
EN 806 (Specications for installations inside buildings
conveying water for human consumption. Operation and
maintenance).
2 . IMPORTANT! The supply pipe must be ushed to clear
debris before connecting to the shower head water inlet.
3. DO NOT solder pipes or ttings within 300mm of the
supplied hoses, as heat can transfer along the pipework
and damage components.
4 . DO NOT use excessive force when making connections to
the exible hose, solenoid or mixer.
5. All plumbing connections must be completed before
making the electrical connections.
6 . Water pressure. Kelda products are designed to operate
between 1 bar and 5 bar, if you wish to operate outside of
this please discuss with a Kelda Engineer.
ELECTRICAL
1 . The installation must comply with BS 7671 ‘Requirements
for electrical installations’ (IEE wiring regulations), building
regulations or any particular regulations as specied by the
local electrical supply company.
2 . In accordance with ‘The Plugs and Sockets etc. (Safety)
Regulations 1994’, this appliance is intended to be
permanently connected to the xed wiring of the electrical
mains system.
3. Make sure all electrical connections are tight to prevent
overheating.
4 . A 32A 30 mA Residual Current Breaker Operator (RCBO)
MUST be installed in all UK electric and pumped shower
circuits. This may be part of the consumer unit or a
separate unit.
5. Other electrical equipment i.e. extractor fans, pumps must
not be connected to the circuits within the unit.
6 . Each shower must be connected to a 3A switched fused
spur which is easily accessible by maintenance sta.
Switch o at fused spur for maintenance or if not in use for
extended periods. This is a safety procedure recommended
with all electrical appliances.
7. As with all electrical appliances it is recommended to
have the shower and installation checked at least every
two years by a competent electrician to ensure there is no
deterioration due to age and usage.
Contact Customer Service (see back page), if any of the
following occur:
a) If it is intended to operate the shower at pressures
above the maximum or below the minimum stated.
b) If the unit shows a distinct change in performance.